Thermooptical detection in microchips: From macro- to micro-scale with enhanced analytical parameters

被引:29
|
作者
Smirnova, Adelina [1 ,2 ]
Proskurnin, Mikhail A. [3 ]
Bendrysheva, Svetlana N. [3 ]
Nedosekin, Dmitry A. [3 ]
Hibara, Akihide [1 ]
Kitamori, Takehiko [1 ,2 ]
机构
[1] Univ Tokyo, Sch Engn, Dept Appl Chem, Bunkyo Ku, Tokyo 1138656, Japan
[2] Japan Sci & Technol Agcy JST, Saitama, Japan
[3] Moscow MV Lomonosov State Univ, Div Analyt Chem, Moscow, Russia
关键词
detection in microchips; optical-scheme optimization; photothermal spectroscopy; thermal-lens microscopy; thermal-lens spectrometry;
D O I
10.1002/elps.200700914
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this paper, we compared the methods of photothermal spectroscopy used in different spatial scales, namely thermal-lens spectrometry (TLS) and thermal-lens microscopy (TLM) to enhance the performance parameters in analytical procedures. All of the experimental results were confirmed by theoretical calculation. It was proven that the design, for both TLM and TLS, despite a different scale for the effect, is governed by the same signal-generating and probing conditions (probe beam diameter at the sample should be equal to the diameter of the blooming thermal lens), and almost does not depend on the nature of the solvent. Theoretical and experimental instrumental error curves for thermal lensing were coincident. TLM obeys the same law of instrumental error as TLS and shows better repeatability for the same levels of thermal-lens signals or absorbances. TLS is more advantageous for studying low concentrations in bulk, while TLM shows much lower absolute LODs due to better repeatability for low amounts. The behavior of the thermal-lens signal with different flow rates was studied and optimum conditions, with the minimum contribution to total error, were found. These conditions are reproducible, are in agreement with the existing theory of the thermal response in thermal lensing, and do not significantly affect the design of the optimum scheme for setups. TLM showed low LODs in solvent extraction (down to 10(-8) M) and electrokinetic separation (10(-7) M), which were shown to be governed by discussed instrumental regularities, instead of by microchemistry.
引用
收藏
页码:2741 / 2753
页数:13
相关论文
共 50 条
  • [41] On the derivation of angiogenesis tissue models: From the micro-scale to the macro-scale
    Bellomo, Nicola
    Bellouquid, Abdelghani
    MATHEMATICS AND MECHANICS OF SOLIDS, 2015, 20 (03) : 268 - 279
  • [42] Economical recycling process for spent lithium-ion batteries and macro- and micro-scale mechanistic study
    Li, Li
    Bian, Yifan
    Zhang, Xiaoxiao
    Xue, Qing
    Fan, Ersha
    Wu, Feng
    Chen, Renjie
    JOURNAL OF POWER SOURCES, 2018, 377 : 70 - 79
  • [43] Idea of macro-scale and micro-scale prestressed ceramics
    Gu, Junfeng
    Fu, Shuai
    Ping, Hang
    Ji, Wei
    Zou, Ji
    Wang, Hao
    Wang, Weimin
    Zhang, Fan
    Liu, Hanxing
    Fu, Zhengyi
    INTERDISCIPLINARY MATERIALS, 2024, 3 (06): : 897 - 906
  • [44] MACRO-SCALE PRODUCTION OF MICRO-SCALE ORGANIC LABORATORY
    SUFFREDINI, CE
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1988, 196 : 99 - CHED
  • [45] Creep Mechanisms of an Al-Cu-Mg Alloy at the Macro- and Micro-Scale: Effect of the S′/S Precipitate
    Xu, Yongqian
    Yang, Lingwei
    Zhan, Lihua
    Yu, Hailiang
    Huang, Minghui
    MATERIALS, 2019, 12 (18)
  • [46] Recent advances in computational simulation of macro-, meso-, and micro-scale biomimetics related fluid flow problems
    Y. Y. Yan
    Journal of Bionic Engineering, 2007, 4 : 97 - 107
  • [47] Recent Advances in Computational Simulation of Macro-,Meso-,and Micro-Scale Biomimetics Related Fluid Flow Problems
    Y. Y. Yan School of the Built Environment
    Journal of Bionics Engineering, 2007, (02) : 97 - 107
  • [48] Grey correlation analysis of macro- and micro-scale properties of aeolian sand concrete under the salt freezing effect
    Zhou, Menghu
    Dong, Wei
    STRUCTURES, 2023, 58
  • [49] Macro and Micro-Scale Modeling of Polyurethane Foaming Processes
    Geier, S.
    Piesche, M.
    PROCEEDINGS OF PPS-29: THE 29TH INTERNATIONAL CONFERENCE OF THE POLYMER - CONFERENCE PAPERS, 2014, 1593 : 560 - 564
  • [50] Recent advances in computational simulation of macro-, meso-, and micro-scale biomimetics related fluid flow problems
    Yan, Y. Y.
    JOURNAL OF BIONIC ENGINEERING, 2007, 4 (02) : 97 - 107