Thermooptical detection in microchips: From macro- to micro-scale with enhanced analytical parameters

被引:29
|
作者
Smirnova, Adelina [1 ,2 ]
Proskurnin, Mikhail A. [3 ]
Bendrysheva, Svetlana N. [3 ]
Nedosekin, Dmitry A. [3 ]
Hibara, Akihide [1 ]
Kitamori, Takehiko [1 ,2 ]
机构
[1] Univ Tokyo, Sch Engn, Dept Appl Chem, Bunkyo Ku, Tokyo 1138656, Japan
[2] Japan Sci & Technol Agcy JST, Saitama, Japan
[3] Moscow MV Lomonosov State Univ, Div Analyt Chem, Moscow, Russia
关键词
detection in microchips; optical-scheme optimization; photothermal spectroscopy; thermal-lens microscopy; thermal-lens spectrometry;
D O I
10.1002/elps.200700914
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this paper, we compared the methods of photothermal spectroscopy used in different spatial scales, namely thermal-lens spectrometry (TLS) and thermal-lens microscopy (TLM) to enhance the performance parameters in analytical procedures. All of the experimental results were confirmed by theoretical calculation. It was proven that the design, for both TLM and TLS, despite a different scale for the effect, is governed by the same signal-generating and probing conditions (probe beam diameter at the sample should be equal to the diameter of the blooming thermal lens), and almost does not depend on the nature of the solvent. Theoretical and experimental instrumental error curves for thermal lensing were coincident. TLM obeys the same law of instrumental error as TLS and shows better repeatability for the same levels of thermal-lens signals or absorbances. TLS is more advantageous for studying low concentrations in bulk, while TLM shows much lower absolute LODs due to better repeatability for low amounts. The behavior of the thermal-lens signal with different flow rates was studied and optimum conditions, with the minimum contribution to total error, were found. These conditions are reproducible, are in agreement with the existing theory of the thermal response in thermal lensing, and do not significantly affect the design of the optimum scheme for setups. TLM showed low LODs in solvent extraction (down to 10(-8) M) and electrokinetic separation (10(-7) M), which were shown to be governed by discussed instrumental regularities, instead of by microchemistry.
引用
收藏
页码:2741 / 2753
页数:13
相关论文
共 50 条
  • [11] Determination of a macro- to micro-scale progression leading to a magnetized plasma disruption
    Seo, Byonghoon
    Wongwaitayakornkul, Pakorn
    Haw, Magnus A.
    Marshall, Ryan S.
    Li, Hui
    Bellan, Paul M.
    PHYSICS OF PLASMAS, 2020, 27 (02)
  • [12] Macro- and micro-scale mixing in a shaken bioreactor for fluids of high viscosity
    Rodriguez, Gregorio
    Micheletti, Martina
    Ducci, Andrea
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2018, 132 : 890 - 901
  • [13] Macro- and Micro-scale Thermal Conductivities of SiC Single Crystal and Ceramic
    Yamada, Ikuko
    Kume, Shoichi
    Nakano, Hiromi
    Watari, Koji
    SIAIONS AND NON-OXIDES, 2009, 403 : 179 - +
  • [14] One hydrophobic coating enables macro- and micro-scale blood contact activation
    Liu, Xiaoli
    Long, Li
    Meng, Limin
    Zhang, Kai
    Zhang, Guochao
    Su, Yang
    Duan, Feng
    Hu, Yang
    Xu, Fu-Jian
    BIOMATERIALS, 2025, 318
  • [15] Macro- and micro-scale studies on U(VI) immobilization in hardened cement paste
    E. Wieland
    N. Macé
    R. Dähn
    D. Kunz
    J. Tits
    Journal of Radioanalytical and Nuclear Chemistry, 2010, 286 : 793 - 800
  • [16] Mechanism of Liquid Dispersion Enhancement by the Hydrophobic Wire Mesh at Macro- and Micro-Scale
    Zhang, Jing-Peng
    Liao, Hai-Long
    Li, Jiang-Nan
    Jiang, Lan
    Luo, Yong
    Ren, Guo-Yu
    Chu, Guang-Wen
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2021, 60 (24) : 8927 - 8934
  • [17] Macro- and micro-scale studies on U(VI) immobilization in hardened cement paste
    Wieland, E.
    Mace, N.
    Daehn, R.
    Kunz, D.
    Tits, J.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2010, 286 (03) : 793 - 800
  • [18] On the macro- and micro-scale of dilute suspensions: A particle-based numerical investigation
    Kijanski, Nadine
    Steeb, Holger
    EUROPEAN JOURNAL OF MECHANICS B-FLUIDS, 2024, 103 : 208 - 222
  • [19] Evaluation of cement stabilised residual soil on macro- and micro-scale for road construction
    Roshan M.J.
    Rashid A.S.B.A.
    Hezmi M.A.B.
    Nejabi M.N.
    Bt.Jusoh S.N.
    Tamassoki S.
    Razali R.
    Journal of Engineering and Applied Science, 2022, 69 (01):
  • [20] BIOFABRICATION OF A PERFUSABLE VASCULAR NETWORK SPANNING FROM THE MACRO- TO THE MICRO-SCALE: A KEY FOR TUMOUR MODELS INVESTIGATION
    Bodet, Tristan
    Mota, Carlos
    Moroni, Lorenzo
    TISSUE ENGINEERING PART A, 2022, 28 : S444 - S444