Thermooptical detection in microchips: From macro- to micro-scale with enhanced analytical parameters

被引:29
|
作者
Smirnova, Adelina [1 ,2 ]
Proskurnin, Mikhail A. [3 ]
Bendrysheva, Svetlana N. [3 ]
Nedosekin, Dmitry A. [3 ]
Hibara, Akihide [1 ]
Kitamori, Takehiko [1 ,2 ]
机构
[1] Univ Tokyo, Sch Engn, Dept Appl Chem, Bunkyo Ku, Tokyo 1138656, Japan
[2] Japan Sci & Technol Agcy JST, Saitama, Japan
[3] Moscow MV Lomonosov State Univ, Div Analyt Chem, Moscow, Russia
关键词
detection in microchips; optical-scheme optimization; photothermal spectroscopy; thermal-lens microscopy; thermal-lens spectrometry;
D O I
10.1002/elps.200700914
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this paper, we compared the methods of photothermal spectroscopy used in different spatial scales, namely thermal-lens spectrometry (TLS) and thermal-lens microscopy (TLM) to enhance the performance parameters in analytical procedures. All of the experimental results were confirmed by theoretical calculation. It was proven that the design, for both TLM and TLS, despite a different scale for the effect, is governed by the same signal-generating and probing conditions (probe beam diameter at the sample should be equal to the diameter of the blooming thermal lens), and almost does not depend on the nature of the solvent. Theoretical and experimental instrumental error curves for thermal lensing were coincident. TLM obeys the same law of instrumental error as TLS and shows better repeatability for the same levels of thermal-lens signals or absorbances. TLS is more advantageous for studying low concentrations in bulk, while TLM shows much lower absolute LODs due to better repeatability for low amounts. The behavior of the thermal-lens signal with different flow rates was studied and optimum conditions, with the minimum contribution to total error, were found. These conditions are reproducible, are in agreement with the existing theory of the thermal response in thermal lensing, and do not significantly affect the design of the optimum scheme for setups. TLM showed low LODs in solvent extraction (down to 10(-8) M) and electrokinetic separation (10(-7) M), which were shown to be governed by discussed instrumental regularities, instead of by microchemistry.
引用
收藏
页码:2741 / 2753
页数:13
相关论文
共 50 条
  • [21] HIGH FREQUENCY OSCILLATIONS IN THE PRE-OPERATIVE ECOG RECORDED AT MACRO- AND MICRO-SCALE
    Fedele, T.
    Hilfiker, P.
    Grunwald, T.
    Stieglitz, L.
    Sarnthein, J.
    EPILEPSIA, 2017, 58 : S117 - S117
  • [22] Exploring the macro- and micro-scale response of an idealised granular material in the direct shear apparatus
    Cui, L.
    O'Sullivan, C.
    GEOTECHNIQUE, 2006, 56 (07): : 455 - 468
  • [23] Macro- and micro-scale culture environment differentially regulate the effects of crowding on macrophage function
    Hsu, Ssu-Chieh J.
    Luu, Thuy U.
    Smith, Tim D.
    Liu, Wendy F.
    BIOTECHNOLOGY AND BIOENGINEERING, 2024, 121 (01) : 306 - 316
  • [24] A multiscale lattice Boltzmann model of macro- to micro-scale transport, with applications to gut function
    Wang, Yanxing
    Brasseur, James G.
    Banco, Gino G.
    Webb, Andrew G.
    Ailiani, Amit C.
    Neuberger, Thomas
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2010, 368 (1921): : 2863 - 2880
  • [25] Micro-scale analytical plasmas for liquid chromatography detection
    Jacob L. Venzie
    R. Kenneth Marcus
    Analytical and Bioanalytical Chemistry, 2005, 381 : 96 - 98
  • [26] Micro-scale analytical plasmas for liquid chromatography detection
    Venzie, JL
    Marcus, RK
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 381 (01) : 96 - 98
  • [27] Recycling of crushed waste clay brick as aggregates in cement mortars: An approach from macro- and micro-scale investigation
    Huang, Qian
    Zhu, Xiaohong
    Xiong, Guangqi
    Wang, Chaoqiang
    Liu, Dongsheng
    Zhao, Liang
    CONSTRUCTION AND BUILDING MATERIALS, 2021, 274
  • [28] Response of anaerobic granular sludge to long-term loading of roxarsone: From macro- to micro-scale perspective
    Tang, Rui
    Luo, Haiping
    Prommer, Henning
    Yue, Zhengbo
    Wang, Wei
    Su, Kuizu
    Hu, Zhen-Hu
    WATER RESEARCH, 2021, 204
  • [29] Measurement of fatigue crack deformation on the macro- and micro-scale: Uniform and non-uniform loading
    O'Connor, S. J.
    Nowell, D.
    Dragnevski, K. I.
    INTERNATIONAL JOURNAL OF FATIGUE, 2016, 89 : 66 - 76
  • [30] HEAT TRANSFER AUGMENTATION OF PARALLEL FLOWS BY MEANS OF ELECTRIC CONDUCTION PHENOMENON IN MACRO- AND MICRO-SCALE
    Yazdani, Miad
    Seyed-Yagoobi, Jamal
    IMECE 2009: PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, VOL 9, PTS A-C, 2010, : 441 - 449