Estimation of Short Circuit Capability of Generator Circuit Breaker For a Generator Fed Fault

被引:0
|
作者
Chanda, K.
Parthasarathi, R.
Holla, S.
机构
关键词
Asymmetry; Circuit Breaker; Electrical; Fault; Generator; Short Circuit; Switchgear;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The Generator Circuit Breaker (GCB) is a core component of a power plant, protecting both the generator and the power transformers. Currently, the only standard that addresses GCB ratings is IEEE C37.013. This standard defines the primary short circuit rating of a GCB based on a system fed fault. When attempting to determine the required ratings for a GCB, it is sometimes difficult to check the capability of a particular model of GCB with respect to the characteristics of the project specific HV system, connected generator, and the associated MV distribution system. The difficulty increases with the emergence of large generators contributing high symmetrical fault current with a very high degree of asymmetry. Many of today's large MVA generators can produce a maximum degree of asymmetry up to 130% for generator fed faults. Currently there are no guidelines available to the end user to determine the suitability of the GCB tested at a certain degree of asymmetry when being applied to a system with a higher degree of asymmetry. This paper provides a discussion on selection of a GCB to interrupt generator-source faults with a high degree of asymmetry. Suitability for a given application may have to be confirmed by the GCB manufacturer.
引用
收藏
页码:352 / 355
页数:4
相关论文
共 50 条
  • [31] Transient current calculation of rectifier generator under converter short circuit fault
    Hou C.
    Zhang X.
    Huang J.
    Wu B.
    Guofang Keji Daxue Xuebao/Journal of National University of Defense Technology, 2021, 43 (04): : 31 - 37
  • [32] HOMOPOLAR GENERATOR EFFECT OF SUDDEN SHORT CIRCUIT
    DASGUPTA, AK
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1968, PA87 (03): : 655 - &
  • [33] Short Circuit Current in the Loaded Synchronous Generator
    Michailidis, Petr
    PROCEEDINGS OF THE 13TH INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRIC POWER ENGINEERING 2012, VOLS 1 AND 2, 2012, : 1117 - 1120
  • [34] Magnetic equivalent circuit modelling of doubly-fed induction generator with assessment of rotor inter-turn short-circuit fault indices
    Faiz, Jawad
    Moosavi, Seyed M. M.
    Abadi, Mohsen B.
    Cruz, Sergio M. A.
    IET RENEWABLE POWER GENERATION, 2016, 10 (09) : 1431 - 1440
  • [35] Voltage Sag Estimation Based on Probabilistic Short Circuit including the Fault Ride Through Effect of Distributed Generator
    Li, Mao
    Xiang, Yu
    Cobben, J. F. G.
    2014 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2014, : 2972 - 2979
  • [36] A Fault Equivalent Network Based Method for Calculating the Doubly Fed Wind Power Generator Short-circuit Currents
    Ma, Jing
    Huang, Tianyi
    Liu, Chang
    Sun, Lvyi
    Thorp, James S.
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2015, 43 (18) : 2069 - 2081
  • [37] Analysis of three-phase short circuit current of doubly fed induction generator
    Zhang, Xue-Guang
    Xu, Dian-Guo
    Li, Wei-Wei
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2008, 12 (05): : 493 - 497
  • [38] Research on Short-Circuit Voltage of Wind Turbines with Doubly Fed Induction Generator
    Yue, Gaili
    Chen, Sha
    Ma, Cunchao
    INTERNATIONAL CONFERENCE ON COMPUTER SCIENCE AND APPLICATION ENGINEERING (CSAE), 2017, 190 : 358 - 366
  • [39] Design of generator circuit breaker failure protection for nuclear power plants
    Xie, Chuangshu
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2014, 38 (06): : 123 - 127
  • [40] GENERATOR CIRCUIT-BREAKER CONSIDERATIONS AT MCGUIRE AND CATAWBA NUCLEAR STATIONS
    PACE, RA
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1976, 95 (03): : 756 - 756