Estimation of Short Circuit Capability of Generator Circuit Breaker For a Generator Fed Fault

被引:0
|
作者
Chanda, K.
Parthasarathi, R.
Holla, S.
机构
关键词
Asymmetry; Circuit Breaker; Electrical; Fault; Generator; Short Circuit; Switchgear;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The Generator Circuit Breaker (GCB) is a core component of a power plant, protecting both the generator and the power transformers. Currently, the only standard that addresses GCB ratings is IEEE C37.013. This standard defines the primary short circuit rating of a GCB based on a system fed fault. When attempting to determine the required ratings for a GCB, it is sometimes difficult to check the capability of a particular model of GCB with respect to the characteristics of the project specific HV system, connected generator, and the associated MV distribution system. The difficulty increases with the emergence of large generators contributing high symmetrical fault current with a very high degree of asymmetry. Many of today's large MVA generators can produce a maximum degree of asymmetry up to 130% for generator fed faults. Currently there are no guidelines available to the end user to determine the suitability of the GCB tested at a certain degree of asymmetry when being applied to a system with a higher degree of asymmetry. This paper provides a discussion on selection of a GCB to interrupt generator-source faults with a high degree of asymmetry. Suitability for a given application may have to be confirmed by the GCB manufacturer.
引用
收藏
页码:352 / 355
页数:4
相关论文
共 50 条
  • [21] Improved generator circuit breaker enhances power plant protection
    Palazzo, Mirko
    Marmolejo, Alejandro
    Fritz, Oliver
    Arndt, Stefan
    ABB Review, 2018, (02): : 84 - 89
  • [22] Current Carrying Capacity of an Earthing Switch for a Generator Circuit Breaker
    Zanetti, A.
    Mauroux, J. -C.
    PROCEEDINGS OF 2018 29TH INTERNATIONAL CONFERENCE ON ELECTRICAL CONTACTS AND 64TH IEEE HOLM CONFERENCE ON ELECTRICAL CONTACTS, 2018, : 113 - 118
  • [23] Current transfer process of paralleled vacuum generator circuit breaker
    School of Electronics and Information Engineering, Dalian Jiaotong University, Dalian 116028, China
    不详
    不详
    Gaodianya Jishu, 2009, 11 (2709-2715):
  • [24] Analysis of short circuit current of wind turbine - Doubly fed induction generator
    Li, D. D.
    ICIEA 2006: 1ST IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-3, PROCEEDINGS, 2006, : 1082 - 1086
  • [25] Short-circuit current of wind turbines with doubly fed induction generator
    Morren, Johan
    de Haan, Sjoerd W. H.
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (01) : 174 - 180
  • [26] Hybrid DC circuit breaker with fault current suppression capability
    Mei, Mingwan
    Wang, Ping
    Che, Yanbo
    Ishaq, Muhammad
    Xing, Chao
    JOURNAL OF POWER ELECTRONICS, 2021, 21 (10) : 1542 - 1555
  • [27] Impact on Superconducting Fault Current Limiters on Circuit Breaker Capability
    Bahirat, H. J.
    Khaparde, S. A.
    Kodle, S.
    Dabeer, V.
    2016 NATIONAL POWER SYSTEMS CONFERENCE (NPSC), 2016,
  • [28] Hybrid DC circuit breaker with fault current suppression capability
    Mingwan Mei
    Ping Wang
    Yanbo Che
    Muhammad Ishaq
    Chao Xing
    Journal of Power Electronics, 2021, 21 : 1542 - 1555
  • [29] Impact of stator interturn short circuit fault on shaft voltage in a synchronous generator
    He, Yu-Ling
    Yang, Pei-Jie
    Sun, Kai
    Xu, Zhen-Li
    Wang, Hai-Peng
    He, Xian-Long
    Gerada, David
    IET ELECTRIC POWER APPLICATIONS, 2023, 17 (03) : 381 - 391
  • [30] Inter turn short-circuit fault research on generator rotor windings
    Li, YG
    Li, HM
    Zhu, L
    Zhao, H
    ICEMS'2001: PROCEEDINGS OF THE FIFTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS I AND II, 2001, : 357 - 360