Research on Short-Circuit Voltage of Wind Turbines with Doubly Fed Induction Generator

被引:0
|
作者
Yue, Gaili [1 ]
Chen, Sha [1 ]
Ma, Cunchao [1 ]
机构
[1] Xian Univ Sci & Technol, Comp Sci & Applicat Engn, Sch Elect & Control Engn, Xian 710054, Shaanxi, Peoples R China
关键词
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
This paper introduces the structure and working principle of doubly fed induction generator, and then establishes mathematical model of DFIG, uses MATLAB simulation environment and set parameters, establishes simulation model. Finally, the simulation results of DFIG grid voltage fault (mainly short circuit fault) are analyzed, the voltage and current waveforms are obtained, and the objectivity of the model is verified, which lay the foundation for the future research on fault control research.
引用
收藏
页码:358 / 366
页数:9
相关论文
共 50 条
  • [1] Short-circuit current of wind turbines with doubly fed induction generator
    Morren, Johan
    de Haan, Sjoerd W. H.
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (01) : 174 - 180
  • [2] Comparison of Short-circuit Current Contribution of Doubly-Fed Induction Generator based Wind Turbines and Synchronous Generator
    Elnaggar, A. K.
    Rueda, J. L.
    Erlich, I.
    2013 IEEE GRENOBLE POWERTECH (POWERTECH), 2013,
  • [3] Research on short-circuit current of doubly fed induction generator under non-deep voltage drop
    Ouyang, Jinxin
    Xiong, Xiaofu
    ELECTRIC POWER SYSTEMS RESEARCH, 2014, 107 : 158 - 166
  • [4] Advanced Short-Circuit Current Calculation for Doubly-Fed Induction Generator Based Wind Turbines According to IEC 60909
    Lager, Thomas
    Hofmann, Lutz
    PROCEEDINGS OF 2019 IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES EUROPE (ISGT-EUROPE), 2019,
  • [5] Short-circuit current of doubly fed induction generator under partial and asymmetrical voltage drop
    Ouyang, Jinxin
    Zheng, Di
    Xiong, Xiaofu
    Xiao, Chao
    Yu, Rui
    RENEWABLE ENERGY, 2016, 88 : 1 - 11
  • [6] Improvement of the Consideration of Short-Circuit Current Contributions from Doubly-Fed Induction Generator Based Wind Turbines for Short-Circuit Current Calculation According to IEC 60909
    Lager, Thomas
    Hofmann, Lutz
    2019 IEEE MILAN POWERTECH, 2019,
  • [7] Short-circuit current reduction techniques of the doubly-fed induction generator based wind turbines for fault ride through enhancement
    El-Naggar, Ahmed
    Erlich, Istvan
    IET RENEWABLE POWER GENERATION, 2017, 11 (07) : 1033 - 1040
  • [8] Short-circuit analysis of a doubly fed induction generator wind turbine with direct current chopper?protection
    Sulla, F.
    Svensson, J.
    Samuelsson, O.
    WIND ENERGY, 2013, 16 (01) : 37 - 49
  • [9] Doubly fed induction generator systems for wind turbines
    Müller, S
    Deicke, M
    De Doncker, RW
    IEEE INDUSTRY APPLICATIONS MAGAZINE, 2002, 8 (03) : 26 - 33
  • [10] Improved Short-Circuit Current Calculation of Doubly Fed Wind Turbines With Uninterrupted Excitation
    Yin, Jun