Post-pinch generation of electron beam in a low energy Mather-type plasma focus device

被引:4
|
作者
Behbahani, R. A. [1 ]
Aghamir, F. M. [1 ]
机构
[1] Univ Tehran, Dept Phys, Tehran 14399, Iran
关键词
X-RAY-EMISSION; OPTIMIZATION; LENGTH; NEON;
D O I
10.1017/S0022377813000470
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
The post-pinch generation of electron beam in a low energy Mather-type plasma focus (PF) device has been investigated. A fast-calibrated Rogowski coil was used to monitor the emission of electron beam. A two-channel diode X-ray spectrometer along with suitable filters provided the records of energy spectrum of X-ray radiation. Single time-period emissions of electron beam with duration of 100 to 20 ns were recorded in the high range of the device operating pressure (0.82-mbar). However, in the low range regime (0.2-0.8 mbar), occurrence of single spike electron beam with duration of 150 +/- 50 ns, as well as multi-emission of electrons with duration of 400 +/- 50 ns, was visible. A multi-peak of tube voltage along with multi-time-period radiation of X-rays dominated by copper lines (Cuk(alpha) and Cuk(beta)) was noticeable in the low-pressure range. The generated electron beam during the post-pinch phase of anomalous resistances is suspected to be the main source of X-ray radiation. This can also be related to the turbulence of the plasma column during the occurrence of anomalous resistances.
引用
收藏
页码:777 / 782
页数:6
相关论文
共 50 条
  • [31] Preliminary Results of 1.5 kJ Mather-Type Plasma Focus with Stainless Steel Anode
    E. Ghareshabani
    Journal of Fusion Energy, 2015, 34 : 1257 - 1262
  • [32] Enhancement of X-ray emission in the side on direction in a Mather-type plasma focus
    M. Sharif
    S. Hussain
    M. Zakaullah
    A. Waheed
    The European Physical Journal D - Atomic, Molecular, Optical and Plasma Physics, 2006, 38 : 337 - 341
  • [33] Preliminary Results of 1.5 kJ Mather-Type Plasma Focus with Stainless Steel Anode
    Ghareshabani, E.
    JOURNAL OF FUSION ENERGY, 2015, 34 (06) : 1257 - 1262
  • [34] Enhancement of X-ray emission in the side on direction in a Mather-type plasma focus
    Sharif, M
    Hussain, S
    Zakaullah, M
    Waheed, A
    EUROPEAN PHYSICAL JOURNAL D, 2006, 38 (02): : 337 - 341
  • [35] Instability of the current sheath implosion in an 18-kJ mather-type plasma focus
    Lu, MF
    Yang, TC
    Han, M
    Yang, SZ
    ICPP 96 CONTRIBUTED PAPERS - PROCEEDINGS OF THE 1996 INTERNATIONAL CONFERENCE ON PLASMA PHYSICS, VOLS 1 AND 2, 1997, : 666 - 669
  • [36] POSSIBLE CORRELATION OF NEUTRON YIELD TO ELECTROMECHANIC WORK IN MATHER-TYPE PLASMA FOCUS DEVICES
    BRUZZONE, HA
    KELLY, HJ
    MILANESE, MM
    POUZO, JO
    NUCLEAR FUSION, 1976, 16 (05) : 870 - 873
  • [37] Instability of the current sheath implosion in an 18-kJ Mather-type plasma focus
    Lu, MF
    PHYSICAL REVIEW E, 1996, 54 (02) : R1074 - R1077
  • [38] Determination of Ion Beam Properties In Nitrogen and Helium Using Mather Type Plasma Focus Device
    Shakonah, Someraa Saleh
    Ali, Jalil
    Rashid, Natashah Abd.
    Chaudhary, Kashif
    JURNAL TEKNOLOGI, 2014, 71 (05):
  • [39] Study on Electron Beam in a Low Energy Plasma Focus
    Khan, Muhammad Zubair
    Ling, Yap Seong
    San, Wong Chiow
    FRONTIERS IN PHYSICS, 2014, 1588 : 185 - 190
  • [40] Deuteron Beam Source Based on Mather Type Plasma Focus
    L. K. Lim
    S. L. Yap
    C. S. Wong
    M. Zakaullah
    Journal of Fusion Energy, 2013, 32 : 287 - 292