Post-pinch generation of electron beam in a low energy Mather-type plasma focus device

被引:4
|
作者
Behbahani, R. A. [1 ]
Aghamir, F. M. [1 ]
机构
[1] Univ Tehran, Dept Phys, Tehran 14399, Iran
关键词
X-RAY-EMISSION; OPTIMIZATION; LENGTH; NEON;
D O I
10.1017/S0022377813000470
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
The post-pinch generation of electron beam in a low energy Mather-type plasma focus (PF) device has been investigated. A fast-calibrated Rogowski coil was used to monitor the emission of electron beam. A two-channel diode X-ray spectrometer along with suitable filters provided the records of energy spectrum of X-ray radiation. Single time-period emissions of electron beam with duration of 100 to 20 ns were recorded in the high range of the device operating pressure (0.82-mbar). However, in the low range regime (0.2-0.8 mbar), occurrence of single spike electron beam with duration of 150 +/- 50 ns, as well as multi-emission of electrons with duration of 400 +/- 50 ns, was visible. A multi-peak of tube voltage along with multi-time-period radiation of X-rays dominated by copper lines (Cuk(alpha) and Cuk(beta)) was noticeable in the low-pressure range. The generated electron beam during the post-pinch phase of anomalous resistances is suspected to be the main source of X-ray radiation. This can also be related to the turbulence of the plasma column during the occurrence of anomalous resistances.
引用
收藏
页码:777 / 782
页数:6
相关论文
共 50 条
  • [1] Time-to-Pinch Investigation of 5 kJ Mather-Type Plasma Focus Device
    Gaber, Walid H.
    Diab, Fathy B.
    Abdel-kader, Mohamed E.
    Ahmed, Kamal M.
    JOURNAL OF FUSION ENERGY, 2018, 37 (01) : 30 - 36
  • [2] Time-to-Pinch Investigation of 5 kJ Mather-Type Plasma Focus Device
    Walid H. Gaber
    Fathy B. Diab
    Mohamed E. Abdel-kader
    Kamal M. Ahmed
    Journal of Fusion Energy, 2018, 37 : 30 - 36
  • [3] Comparative study of low energy Mather-type plasma focus devices
    Zakaullah, M.
    Murtaza, G.
    Ahmad, Imtiaz
    Beg, Farhat N.
    Beg, M.M.
    Shabbir, M.
    Plasma Sources Science and Technology, 1995, 4 (01): : 117 - 124
  • [4] Effect of anode shape on correlation of neutron emission with pinch energy for a 2.7 kJ Mather-type plasma focus device
    Hussain, S. S.
    Ahmad, S.
    Murtaza, Ghulam
    Zakaullah, M.
    JOURNAL OF APPLIED PHYSICS, 2009, 106 (02)
  • [5] Effect of anode shape on correlation of neutron emission with pinch energy for a 2.7 kJ Mather-type plasma focus device
    Hussain, S.S.
    Ahmad, S.
    Murtaza, Ghulam
    Zakaullah, M.
    Journal of Applied Physics, 2009, 106 (02):
  • [6] Current sheath behavior and its velocity enhancement in a low energy Mather-type plasma focus device
    Aghamir, F. M.
    Behbahani, R. A.
    JOURNAL OF APPLIED PHYSICS, 2011, 109 (04)
  • [7] Correlation of current drop, filling gas pressure, and ion beam emission in a low energy Mather-type plasma focus device
    Behbahani, R. A.
    Aghamir, F. M.
    JOURNAL OF APPLIED PHYSICS, 2012, 111 (04)
  • [8] Energy spectrum of multi-radiation of X-rays in a low energy Mather-type plasma focus device
    Aghamir, Farzin M.
    Behbahani, Reza A.
    CHINESE PHYSICS B, 2014, 23 (06)
  • [9] Energy spectrum of multi-radiation of X-rays in a low energy Mather-type plasma focus device
    Farzin M.Aghamir
    Reza A.Behbahani
    Chinese Physics B, 2014, (06) : 379 - 384
  • [10] Design of a 500-kJ Mather-type plasma focus device
    A. Heidarnia
    A. Sadighzadeh
    A. A. Zaeem
    V. Damideh
    Plasma Physics Reports, 2016, 42 : 1106 - 1110