Simultaneous analysis of codeine and its active metabolites in human plasma using liquid chromatography-tandem mass spectrometry: Application to a pharmacokinetic study after oral administration of codeine

被引:10
|
作者
Wu, Xiujun [1 ,2 ]
Zhang, Weiping [3 ]
Bai, Yin [4 ]
Guo, Tao [1 ]
Gu, Jingkai [5 ]
机构
[1] Shenyang Northern Hosp, Dept Pharm, Shenyang 110016, Peoples R China
[2] Liaoning Univ Tradit Chinese Med, Affiliated Hosp, Shenyang 110032, Peoples R China
[3] Shenyang Pharmaceut Univ, Sch Tradit Chinese Mat Med, Shenyang 110016, Peoples R China
[4] Chifeng Univ, Coll Med Sci, Chifeng 024000, Peoples R China
[5] Jilin Univ, Coll Life Sci, Res Ctr Drug Metab, Changchun 130021, Peoples R China
关键词
Codeine; Morphine; 3; beta-glucuronide; 6; LC MS/MS; INTERETHNIC DIFFERENCES; EXTENSIVE METABOLIZERS; GC-MS; MORPHINE; 6-MONOACETYLMORPHINE; 6-GLUCURONIDES; QUANTIFICATION; GLUCURONIDE; OPIATES; BLOOD;
D O I
10.1016/j.jpba.2013.02.027
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid and sensitive bioassay based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed and validated for the simultaneous determination of codeine and its active metabolites, including morphine, morphine 3 beta-glucuronide (M3G) and morphine 6 beta-glucuronide (M6G), in human plasma. Sample preparation of plasma after the addition of naloxone as internal standard (IS) involved solid-phase extraction (SPE) on C18 cartridges. Reversed-phase chromatography using a gradient elution with methanol and 0.04% formic acid solution (pH 3.5) was used for separation in a run time of 5 min. The analytes were detected in the positive ion mode using multiple reaction monitoring (MRM) of the transitions at m/z 300.4 -> 215.2 for codeine, 286.2 -> 152.0 for morphine, and 462.2 -> 286.2 for M3G and M6G. The method has the following performance characteristics: a reliable response range of 0.05-80 ng/ml for codeine, M3G and M6G and a response range of 0.05-5.0 ng/ml for morphine with correlation coefficients (r) of >0.997 for all analytes. The lower limit of quantitation (LLOQ) for all four analytes was 0.05 ng/ml. The intra- and inter-day precision and accuracy of the quality control samples at low, medium and high concentration levels showed <12% relative standard deviation (RSD) and -6.9 to 8.1% relative error (RE) for all the analytes. The method was successfully applied to a pharmacokinetic study of codeine in healthy Mongolian Chinese volunteers after a 30 mg oral dose. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:261 / 268
页数:8
相关论文
共 50 条
  • [41] Liquid chromatography-tandem mass/mass spectrometry method for the quantification of rabeprazole in human plasma and application to a pharmacokinetic study
    Yu, Liyan
    Deng, Haishan
    Xiang, Bingren
    ARZNEIMITTELFORSCHUNG-DRUG RESEARCH, 2010, 60 (05): : 262 - 266
  • [42] Simultaneous determination of probe drugs, metabolites, inhibitors and inducer in human plasma by liquid chromatography/tandem mass spectrometry and its application to pharmacokinetic study
    Hee, Kim H.
    Yao, Zhangyan
    Lee, Lawrence S.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 88 : 584 - 593
  • [43] Hydrophilic interaction liquid chromatography-tandem mass spectrometry for the determination of adefovir in human plasma and its application to a pharmacokinetic study
    Xiong, Zhili
    Zhang, Yi
    Qin, Feng
    Qin, Ting
    Yang, Shuyan
    Li, Famei
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (23): : 2111 - 2116
  • [45] An ultraperformance liquid chromatography-tandem mass spectrometry method for determination of anastrozole in human plasma and its application to a pharmacokinetic study
    Yu, Jia
    He, Jifen
    Zhang, Yi
    Qin, Feng
    Xiong, Zhili
    Li, Famei
    BIOMEDICAL CHROMATOGRAPHY, 2011, 25 (04) : 511 - 516
  • [46] Determination of nifedipine in human plasma by ultra performance liquid chromatography-tandem mass spectrometry and its application in a pharmacokinetic study
    Wang, Dan
    Jiang, Kun
    Yang, Shuyan
    Qin, Feng
    Lu, Xiumei
    Li, Famei
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (20): : 1827 - 1832
  • [47] Quantification of Colistin in Plasma by Liquid Chromatography-Tandem Mass Spectrometry: Application to a Pharmacokinetic Study
    Matar, Kamal M.
    Al-Refai, Batool
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [48] Quantification of Colistin in Plasma by Liquid Chromatography-Tandem Mass Spectrometry: Application to a Pharmacokinetic Study
    Kamal M. Matar
    Batool Al-Refai
    Scientific Reports, 10
  • [49] Simultaneous determination of clevidipine and its primary metabolite in dog plasma by liquid chromatography-tandem mass spectrometry: Application to pharmacokinetic study
    Zhou, Ying
    Li, Huqun
    He, Xiaomeng
    Jia, Mengmeng
    Ni, Yang
    Xu, Mingzhen
    Chen, Hui
    Li, Weiyong
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 100 : 294 - 299
  • [50] Determination of palonosetron in human plasma by ultra performance liquid chromatography-tandem mass spectrometry and its application to a pharmacokinetic study
    Yang, Shuyan
    Qin, Feng
    Wang, Dan
    Li, Ning
    Li, Famei
    Xiong, Zhili
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 57 : 13 - 18