Simultaneous analysis of codeine and its active metabolites in human plasma using liquid chromatography-tandem mass spectrometry: Application to a pharmacokinetic study after oral administration of codeine

被引:10
|
作者
Wu, Xiujun [1 ,2 ]
Zhang, Weiping [3 ]
Bai, Yin [4 ]
Guo, Tao [1 ]
Gu, Jingkai [5 ]
机构
[1] Shenyang Northern Hosp, Dept Pharm, Shenyang 110016, Peoples R China
[2] Liaoning Univ Tradit Chinese Med, Affiliated Hosp, Shenyang 110032, Peoples R China
[3] Shenyang Pharmaceut Univ, Sch Tradit Chinese Mat Med, Shenyang 110016, Peoples R China
[4] Chifeng Univ, Coll Med Sci, Chifeng 024000, Peoples R China
[5] Jilin Univ, Coll Life Sci, Res Ctr Drug Metab, Changchun 130021, Peoples R China
关键词
Codeine; Morphine; 3; beta-glucuronide; 6; LC MS/MS; INTERETHNIC DIFFERENCES; EXTENSIVE METABOLIZERS; GC-MS; MORPHINE; 6-MONOACETYLMORPHINE; 6-GLUCURONIDES; QUANTIFICATION; GLUCURONIDE; OPIATES; BLOOD;
D O I
10.1016/j.jpba.2013.02.027
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid and sensitive bioassay based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed and validated for the simultaneous determination of codeine and its active metabolites, including morphine, morphine 3 beta-glucuronide (M3G) and morphine 6 beta-glucuronide (M6G), in human plasma. Sample preparation of plasma after the addition of naloxone as internal standard (IS) involved solid-phase extraction (SPE) on C18 cartridges. Reversed-phase chromatography using a gradient elution with methanol and 0.04% formic acid solution (pH 3.5) was used for separation in a run time of 5 min. The analytes were detected in the positive ion mode using multiple reaction monitoring (MRM) of the transitions at m/z 300.4 -> 215.2 for codeine, 286.2 -> 152.0 for morphine, and 462.2 -> 286.2 for M3G and M6G. The method has the following performance characteristics: a reliable response range of 0.05-80 ng/ml for codeine, M3G and M6G and a response range of 0.05-5.0 ng/ml for morphine with correlation coefficients (r) of >0.997 for all analytes. The lower limit of quantitation (LLOQ) for all four analytes was 0.05 ng/ml. The intra- and inter-day precision and accuracy of the quality control samples at low, medium and high concentration levels showed <12% relative standard deviation (RSD) and -6.9 to 8.1% relative error (RE) for all the analytes. The method was successfully applied to a pharmacokinetic study of codeine in healthy Mongolian Chinese volunteers after a 30 mg oral dose. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:261 / 268
页数:8
相关论文
共 50 条
  • [31] Simultaneous determination of ebastine and its three metabolites in plasma using liquid chromatography-tandem mass spectrometry
    Kang, WK
    Liu, KH
    Ryu, JY
    Shin, JG
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 813 (1-2): : 75 - 80
  • [32] A liquid chromatography-tandem mass spectrometry method for the simultaneous quantification of escin Ia and escin Ib in human plasma: application to a pharmacokinetic study after intravenous administration
    Liu, Lidong
    Wu, Xiujun
    Wu, Dan
    Wang, Yingwu
    Li, Pengfei
    Sun, Yantong
    Yang, Yan
    Gu, Jingkai
    Cui, Yimin
    BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (12) : 1309 - 1315
  • [33] Simultaneous Quantification of 3′- and 6′-Sialyllactose in Rat Plasma Using Liquid Chromatography-Tandem Mass Spectrometry and Its Application to a Pharmacokinetic Study
    Jang, Seok-In
    Eom, Han Young
    Hwang, Jeong Ho
    Kim, Lila
    Lee, Jong-Hwa
    MOLECULES, 2021, 26 (04):
  • [34] Simultaneous quantification of curdione, furanodiene and germacrone in rabbit plasma using liquid chromatography-tandem mass spectrometry and its application to a pharmacokinetic study
    Wang, Baolian
    Yang, Shuang
    Sheng, Li
    Li, Yan
    BIOMEDICAL CHROMATOGRAPHY, 2015, 29 (09) : 1393 - 1398
  • [35] Simultaneous determination of azelnidipine and two metabolites in human plasma using liquid chromatography-tandem mass spectrometry
    Kawabata, Kiyoshi
    Urasaki, Yoko
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 844 (01): : 45 - 52
  • [36] Determination of henatinib in human plasma and urine by liquid chromatography-tandem mass spectrometry and its pharmacokinetic application
    Qian, Jun
    Wang, Yixuan
    Cao, Junning
    Li, Jin
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 80 : 173 - 179
  • [37] Simultaneous determination of macitentan and its active metabolite in human plasma by liquid chromatography-tandem mass spectrometry
    Yu, Lixiu
    Zhou, Ying
    He, Xiaomeng
    Li, Huqun
    Chen, Hui
    Li, Weiyong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 1002 : 358 - 363
  • [38] Simultaneous quantification of atorvastatin and active metabolites in human plasma by liquid chromatography-tandem mass spectrometry using rosuvastatin as internal standard
    Nirogi, Ramakrishna V. S.
    Kandikere, Vishwottam N.
    Shukla, Manoj
    Mudigonda, Koteshwara
    Maurya, Santosh
    Boosi, Ravikurnar
    Anjaneyulu, Yerramilli
    BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (09) : 924 - 936
  • [39] Simultaneous Quantification of Filgotinib and Its Active Metabolite in Human Plasma Using Liquid Chromatography-Tandem Mass Spectrometry: Validation and Clinical Application
    Ito, Takahiro
    Suno, Manabu
    Shintani, Minae
    Iwata, Ayaka
    Fujii, Takao
    Matsubara, Kazuo
    BIOMEDICAL CHROMATOGRAPHY, 2025, 39 (04)
  • [40] Determination of limonin in dog plasma by liquid chromatography-tandem mass spectrometry and its application to a pharmacokinetic study
    Liu, Shi-jia
    Zhou, Ling
    Zhang, Jun
    Yu, Bo-yang
    Li, Chang-yin
    Liu, Zi-xiu
    Ju, Wen-zheng
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (04) : 515 - 519