Simultaneous analysis of codeine and its active metabolites in human plasma using liquid chromatography-tandem mass spectrometry: Application to a pharmacokinetic study after oral administration of codeine

被引:10
|
作者
Wu, Xiujun [1 ,2 ]
Zhang, Weiping [3 ]
Bai, Yin [4 ]
Guo, Tao [1 ]
Gu, Jingkai [5 ]
机构
[1] Shenyang Northern Hosp, Dept Pharm, Shenyang 110016, Peoples R China
[2] Liaoning Univ Tradit Chinese Med, Affiliated Hosp, Shenyang 110032, Peoples R China
[3] Shenyang Pharmaceut Univ, Sch Tradit Chinese Mat Med, Shenyang 110016, Peoples R China
[4] Chifeng Univ, Coll Med Sci, Chifeng 024000, Peoples R China
[5] Jilin Univ, Coll Life Sci, Res Ctr Drug Metab, Changchun 130021, Peoples R China
关键词
Codeine; Morphine; 3; beta-glucuronide; 6; LC MS/MS; INTERETHNIC DIFFERENCES; EXTENSIVE METABOLIZERS; GC-MS; MORPHINE; 6-MONOACETYLMORPHINE; 6-GLUCURONIDES; QUANTIFICATION; GLUCURONIDE; OPIATES; BLOOD;
D O I
10.1016/j.jpba.2013.02.027
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid and sensitive bioassay based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed and validated for the simultaneous determination of codeine and its active metabolites, including morphine, morphine 3 beta-glucuronide (M3G) and morphine 6 beta-glucuronide (M6G), in human plasma. Sample preparation of plasma after the addition of naloxone as internal standard (IS) involved solid-phase extraction (SPE) on C18 cartridges. Reversed-phase chromatography using a gradient elution with methanol and 0.04% formic acid solution (pH 3.5) was used for separation in a run time of 5 min. The analytes were detected in the positive ion mode using multiple reaction monitoring (MRM) of the transitions at m/z 300.4 -> 215.2 for codeine, 286.2 -> 152.0 for morphine, and 462.2 -> 286.2 for M3G and M6G. The method has the following performance characteristics: a reliable response range of 0.05-80 ng/ml for codeine, M3G and M6G and a response range of 0.05-5.0 ng/ml for morphine with correlation coefficients (r) of >0.997 for all analytes. The lower limit of quantitation (LLOQ) for all four analytes was 0.05 ng/ml. The intra- and inter-day precision and accuracy of the quality control samples at low, medium and high concentration levels showed <12% relative standard deviation (RSD) and -6.9 to 8.1% relative error (RE) for all the analytes. The method was successfully applied to a pharmacokinetic study of codeine in healthy Mongolian Chinese volunteers after a 30 mg oral dose. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:261 / 268
页数:8
相关论文
共 50 条
  • [21] Determination of atomoxetine metabolites in human plasma by liquid chromatography/tandem mass spectrometry and its application to a pharmacokinetic study
    Choi, Chang-Ik
    Bae, Jung-Woo
    Lee, Hye-In
    Jang, Choon-Gon
    Sohn, Uy Dong
    Lee, Seok-Yong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 885 : 103 - 108
  • [22] Liquid chromatography-tandem mass spectrometry method for determination of rivaroxaban in human plasma and its application to a pharmacokinetic study
    Shaikh, Khurshid
    Mungantiwar, Ashish
    Halde, Supriya
    Pandita, Nancy
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2020, 26 (02) : 91 - 105
  • [23] Bioanalysis of bedaquiline in human plasma by liquid chromatography-tandem mass spectrometry: Application to pharmacokinetic study
    Bezawada, Viritha
    Mogili, Padma
    Polagani, Srinivasa Rao
    Dodda, Sireesha
    JOURNAL OF MASS SPECTROMETRY AND ADVANCES IN THE CLINICAL LAB, 2024, 31 : 27 - 32
  • [24] Simultaneous determination of alflutinib and its active metabolite in human plasma using liquid chromatography-tandem mass spectrometry
    Liu, Xiaoyun
    Li, Wei
    Zhang, Yifan
    Jian, Yong
    Zhao, Qianyu
    Zhong, Dafang
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 176
  • [25] Simultaneous analysis of THC and its metabolites in blood using liquid chromatography-tandem mass spectrometry
    Ramirez Fernandez, Maria del Mar
    De Boeck, Gert
    Wood, Michelle
    Lopez-Rivadulla, Manuel
    Samyn, Nele
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 875 (02): : 465 - 470
  • [26] Simultaneous quantitation of lamivudine, zidovudine and nevirapine in human plasma by liquid chromatography-tandem mass spectrometry and application to a pharmacokinetic study
    Matta, Murali Krishna
    Pilli, Nageswara Rao
    Inamadugu, Jaswanth Kumar
    Burugula, Laxminarayana
    Rao, Seshagiri J. V. L. N.
    ACTA PHARMACEUTICA SINICA B, 2012, 2 (05) : 472 - 480
  • [27] Simultaneous determination of 1,5-dicaffeoylquinic acid and its active metabolites in human plasma by liquid chromatography-tandem mass spectrometry for pharmacokinetic studies
    Gu, Ruolan
    Dou, Guifang
    Wang, Jing
    Dong, Junxing
    Meng, Zhiyun
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2): : 85 - 91
  • [28] Analysis of fenretinide and its metabolites in human plasma by liquid chromatography-tandem mass spectrometry and its application to clinical pharmacokinetics
    Cho, Hwang Eui
    Kang, Min H.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 132 : 117 - 124
  • [29] Quantification of oltipraz using liquid chromatography-tandem mass spectrometry and its application to a pharmacokinetic study in rat plasma
    Lee, Jong-Hwa
    Lim, Hwanmi
    Kim, Do-Geun
    Park, Dae-Hun
    Woo, Young-Ah
    Noh, Hyun-Jung
    Jin, Qing-Ri
    Lee, Kyeong-Ryoon
    Lee, Gye-Won
    Kim, Choong-Yong
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 56 (03) : 623 - 626
  • [30] Simultaneous determination of aceclofenac and its three metabolites in plasma using liquid chromatography-tandem mass spectrometry
    Kang, Wonku
    Kim, Eun-Young
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 46 (03) : 587 - 591