Comparison of Surgical Outcomes of Large Orbital Fractures Reconstructed With Porous Polyethylene Channel and Porous Polyethylene Titan Barrier Implants

被引:18
|
作者
Kim, Chang Yeom [1 ]
Jeong, Byung Jin [2 ]
Lee, Sang Yeul [1 ]
Yoon, Jin Sook [1 ]
机构
[1] Yonsei Univ, Coll Med, Inst Vis Res, Dept Ophthalmol, Seoul 120752, South Korea
[2] Cheil Eye Hosp, Div Oculoplasty, Taegu, South Korea
来源
关键词
MEDPOR; SURGERY;
D O I
10.1097/IOP.0b013e3182467c4a
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the postoperative outcomes of large orbital fractures repaired with porous polyethylene (PP) channel implants (PPCIs) and PP titan barrier implants (PPTBs). Methods: Medical records of 42 patients who underwent surgical reconstruction for a large orbital fracture with either PPCI or PPTB were reviewed retrospectively. The degree of diplopia, determined with a binocular single vision test, and enophthalmos, measured by a Hertel exophthalmometer, was compared between 2 implant groups. Orbital volumes were calculated using CT scans and the measuring tool. Results: Of the 42 patients examined, 16 received PPCI and 26 received PPTB. No significant difference in the degree of diplopia was observed between the 2 implant groups before surgery, and 1 and 3 months after surgery (p = 0.256, 0.408, and 0.432, respectively). Preoperative average enophthalmos measuring 1.28 mm and 1.04 mm was successfully corrected to 0.19 mm and 0.25 mm 3 months after reconstruction with PPCI and PPTB, respectively. The fractured orbit volumes and nonfractured contralateral orbit volumes were 24.96 +/- 2.32 cm(3) and 23.18 +/- 1.73 cm(3) in the PPCI group, and 26.80 +/- 2.10 cm(3) and 24.13 +/- 2.28 cm(3) in the PPTB group, respectively. After surgery, the fractured orbit volumes significantly decreased to 23.39 +/- 2.82 cm(3) in the PPCI group and to 23.53 +/- 1.74 cm(3) in the PPTB group; these values were not significantly different from that of the nonfractured orbit (p = 0.681 for PPCI and 0.204 for PPTB). Conclusions: Porous polyethylene channel implant and PPTB are both effective implant materials for the repair of large orbital fractures; however, PPTB has the additional benefit of not requiring screw fixation. (Ophthal Plast Reconstr Surg 2012;28:176-180)
引用
收藏
页码:176 / 180
页数:5
相关论文
共 50 条
  • [41] Fibrovascular ingrowth into hydroxyapatite and porous polyethylene orbital implants wrapped with acellular dermis
    Thakker, MM
    Fay, AM
    Pieroth, L
    Rubin, PAD
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2004, 20 (05): : 368 - 373
  • [42] Custom Porous Polyethylene Implants for Large-scale Pediatric Skull Reconstruction: Early Outcomes
    Lin, Alexander Y.
    Kinsella, Christopher R., Jr.
    Rottgers, S. Alex
    Smith, Darren M.
    Grunwaldt, Lorelei J.
    Cooper, Gregory M.
    Losee, Joseph E.
    JOURNAL OF CRANIOFACIAL SURGERY, 2012, 23 (01) : 67 - 70
  • [43] Orbital reconstruction using custom-made orbital alloplastic porous polyethylene implants.
    Goodman, RL
    Holck, DE
    Ng, JD
    Kikkawa, DO
    Piest, KL
    Otto, R
    Soparkar, CN
    Patrinely, JR
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S342 - S342
  • [44] A comparison of porous polyethylene enucleation implants with and without acellular dermis wrapping
    Avery, RB
    Lucarelli, MJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U329 - U329
  • [45] Comparison of synthetic hydroxyapatite and porous polyethylene implants in eviscerated rabbit eyes
    Jordan, DR
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2004, 20 (02): : 174 - 175
  • [46] Comparison of synthetic hydroxyapatite and porous polyethylene implants in eviscerated rabbit eyes
    Schellini, SA
    Marques, MEA
    Padovani, CR
    Taga, EM
    Rossa, R
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2003, 19 (02): : 136 - 139
  • [47] Porous polyethylene implants in orbital floor reconstruction (vol 109, pg 877, 2002)
    Iliff, N
    Robertson, B
    Villareal, PM
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2003, 111 (02) : 978 - 978
  • [48] Clinical experience with high density porous polyethylene (Medpor) orbital implants in children.
    Kumar, V
    Ainsworth, JR
    Willshaw, HE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S342 - S342
  • [49] Reconstruction of orbital floor fractures using a porous polyethylene implant: outcomes in the early, intermediate and late postoperative periods
    Ozkaya, Nese Kurt
    Ercocen, Ali Riza
    ENT UPDATES, 2020, 10 (02): : 321 - 325
  • [50] Long-term outcomes of ultra-thin porous polyethylene implants used for reconstruction of orbital floor defects
    Ozturk, S
    Sengezer, M
    Isik, S
    Turegun, M
    Deveci, M
    Cil, Y
    JOURNAL OF CRANIOFACIAL SURGERY, 2005, 16 (06) : 973 - 977