Comparison of Surgical Outcomes of Large Orbital Fractures Reconstructed With Porous Polyethylene Channel and Porous Polyethylene Titan Barrier Implants

被引:18
|
作者
Kim, Chang Yeom [1 ]
Jeong, Byung Jin [2 ]
Lee, Sang Yeul [1 ]
Yoon, Jin Sook [1 ]
机构
[1] Yonsei Univ, Coll Med, Inst Vis Res, Dept Ophthalmol, Seoul 120752, South Korea
[2] Cheil Eye Hosp, Div Oculoplasty, Taegu, South Korea
来源
关键词
MEDPOR; SURGERY;
D O I
10.1097/IOP.0b013e3182467c4a
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the postoperative outcomes of large orbital fractures repaired with porous polyethylene (PP) channel implants (PPCIs) and PP titan barrier implants (PPTBs). Methods: Medical records of 42 patients who underwent surgical reconstruction for a large orbital fracture with either PPCI or PPTB were reviewed retrospectively. The degree of diplopia, determined with a binocular single vision test, and enophthalmos, measured by a Hertel exophthalmometer, was compared between 2 implant groups. Orbital volumes were calculated using CT scans and the measuring tool. Results: Of the 42 patients examined, 16 received PPCI and 26 received PPTB. No significant difference in the degree of diplopia was observed between the 2 implant groups before surgery, and 1 and 3 months after surgery (p = 0.256, 0.408, and 0.432, respectively). Preoperative average enophthalmos measuring 1.28 mm and 1.04 mm was successfully corrected to 0.19 mm and 0.25 mm 3 months after reconstruction with PPCI and PPTB, respectively. The fractured orbit volumes and nonfractured contralateral orbit volumes were 24.96 +/- 2.32 cm(3) and 23.18 +/- 1.73 cm(3) in the PPCI group, and 26.80 +/- 2.10 cm(3) and 24.13 +/- 2.28 cm(3) in the PPTB group, respectively. After surgery, the fractured orbit volumes significantly decreased to 23.39 +/- 2.82 cm(3) in the PPCI group and to 23.53 +/- 1.74 cm(3) in the PPTB group; these values were not significantly different from that of the nonfractured orbit (p = 0.681 for PPCI and 0.204 for PPTB). Conclusions: Porous polyethylene channel implant and PPTB are both effective implant materials for the repair of large orbital fractures; however, PPTB has the additional benefit of not requiring screw fixation. (Ophthal Plast Reconstr Surg 2012;28:176-180)
引用
收藏
页码:176 / 180
页数:5
相关论文
共 50 条
  • [31] Effects and complications of placement of motility coupling post in porous polyethylene orbital implants
    Hong-guang Cui
    Rong-rong Hu
    Hui-yan Li
    Wei Han
    Journal of Zhejiang University SCIENCE B, 2008, 9 : 464 - 469
  • [32] Porous polyethylene (MedPor) orbital implants in retinoblastoma patients demonstrate enhancement on MRI
    Hubbard, G
    Sippy, BD
    Aaberg, TM
    Cinnamon, J
    Grossniklaus, HE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U381 - U381
  • [33] Magnetic resonance imaging assessment of fibrovascular ingrowth into porous polyethylene orbital implants
    Choi, Hee Young
    Lee, Jong Soo
    Park, Hyun Jun
    Oum, Boo Sup
    Kim, Hak Jin
    Park, Do Youn
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 34 (04): : 354 - 359
  • [34] Effects and complications of placement of motility coupling post in porous polyethylene orbital implants
    Cui, Hong-guang
    Hu, Rong-rong
    Li, Hui-yan
    Han, Wei
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE B, 2008, 9 (06): : 464 - 469
  • [36] Effect of synthetic bone glass particulate on the fibrovascularization of porous polyethylene orbital implants
    Choi, HY
    Lee, JE
    Park, HJ
    Oum, BS
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2006, 22 (02): : 121 - 125
  • [37] Fibrovascular Ingrowth Into Porous Polyethylene Orbital Implants (Medpor) After Modified Evisceration
    Huang, Danping
    Xu, Binbin
    Yang, Zhiyun
    Xu, Bing
    Lin, Xiaolei
    Yang, Xiaonan
    Zhao, Jing
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2015, 31 (02): : 139 - 144
  • [38] Orbital Bony Reconstruction With Presized and Precontoured Porous Polyethylene-Titanium Implants
    Blessing, Nathan W.
    Rong, Andrew J.
    Tse, Brian C.
    Erickson, Benjamin P.
    Lee, Bradford W.
    Johnson, Thomas E.
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2021, 37 (03): : 284 - 289
  • [39] Porous Polyethylene (Medpor) Orbital Implants with Primary Acellular Dermis Patch Grafts
    Kadyan, Anju
    Sandramouli, Soupramanien
    ORBIT-AN INTERNATIONAL JOURNAL ON ORBITAL DISORDERS AND FACIAL RECONSTRUCTIVE SURGERY, 2008, 27 (01): : 19 - 23
  • [40] Unwrapped conical and spherical porous polyethylene (MEDPOR) orbital implants in primary enucleation
    Cook, T
    Lucarelli, MJ
    Lemke, BN