Comparison of Surgical Outcomes of Large Orbital Fractures Reconstructed With Porous Polyethylene Channel and Porous Polyethylene Titan Barrier Implants

被引:18
|
作者
Kim, Chang Yeom [1 ]
Jeong, Byung Jin [2 ]
Lee, Sang Yeul [1 ]
Yoon, Jin Sook [1 ]
机构
[1] Yonsei Univ, Coll Med, Inst Vis Res, Dept Ophthalmol, Seoul 120752, South Korea
[2] Cheil Eye Hosp, Div Oculoplasty, Taegu, South Korea
来源
关键词
MEDPOR; SURGERY;
D O I
10.1097/IOP.0b013e3182467c4a
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the postoperative outcomes of large orbital fractures repaired with porous polyethylene (PP) channel implants (PPCIs) and PP titan barrier implants (PPTBs). Methods: Medical records of 42 patients who underwent surgical reconstruction for a large orbital fracture with either PPCI or PPTB were reviewed retrospectively. The degree of diplopia, determined with a binocular single vision test, and enophthalmos, measured by a Hertel exophthalmometer, was compared between 2 implant groups. Orbital volumes were calculated using CT scans and the measuring tool. Results: Of the 42 patients examined, 16 received PPCI and 26 received PPTB. No significant difference in the degree of diplopia was observed between the 2 implant groups before surgery, and 1 and 3 months after surgery (p = 0.256, 0.408, and 0.432, respectively). Preoperative average enophthalmos measuring 1.28 mm and 1.04 mm was successfully corrected to 0.19 mm and 0.25 mm 3 months after reconstruction with PPCI and PPTB, respectively. The fractured orbit volumes and nonfractured contralateral orbit volumes were 24.96 +/- 2.32 cm(3) and 23.18 +/- 1.73 cm(3) in the PPCI group, and 26.80 +/- 2.10 cm(3) and 24.13 +/- 2.28 cm(3) in the PPTB group, respectively. After surgery, the fractured orbit volumes significantly decreased to 23.39 +/- 2.82 cm(3) in the PPCI group and to 23.53 +/- 1.74 cm(3) in the PPTB group; these values were not significantly different from that of the nonfractured orbit (p = 0.681 for PPCI and 0.204 for PPTB). Conclusions: Porous polyethylene channel implant and PPTB are both effective implant materials for the repair of large orbital fractures; however, PPTB has the additional benefit of not requiring screw fixation. (Ophthal Plast Reconstr Surg 2012;28:176-180)
引用
收藏
页码:176 / 180
页数:5
相关论文
共 50 条
  • [21] Comparison of synthetic hydroxyapatite and porous polyethylene implants
    Schellini, SA
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2004, 20 (02): : 175 - 176
  • [22] Plasma surface modification of porous polyethylene implants in orbital reconstruction
    Yang, Seong-Won
    Park, Saemi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [23] Medpor porous polyethylene implants in orbital blowout fracture repair
    Ng, SGJ
    Madill, SA
    Inkster, CF
    Maloof, AJ
    Leatherbarrow, B
    EYE, 2001, 15 (5) : 578 - 582
  • [24] Medpor porous polyethylene implants in orbital blowout fracture repair
    S G J Ng
    S A Madill
    C F Inkster
    A J Maloof
    B Leatherbarrow
    Eye, 2001, 15 : 578 - 582
  • [25] Cranioplasty of Large Cranial Defects With Porous Polyethylene Implants
    Kumar, Nanukuttan Girish
    Sreenivas, Mukkamala
    Gowda, Srinivas
    JOURNAL OF CRANIOFACIAL SURGERY, 2016, 27 (04) : E333 - E335
  • [26] Orbital fracture repair outcomes with preformed titanium mesh implants and comparison to porous polyethylene coated titanium sheets
    Peng, Michelle Y.
    Merbs, Shannath L.
    Grant, Michael P.
    Mahoney, Nicholas R.
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2017, 45 (02) : 271 - 274
  • [27] Primary placement of a motility coupling post in porous polyethylene orbital implants
    Rubin, PAD
    Fay, AM
    Remulla, HD
    ARCHIVES OF OPHTHALMOLOGY, 2000, 118 (06) : 826 - 832
  • [28] Clinical and Histopathologic Review of 18 Explanted Porous Polyethylene Orbital Implants
    Chuo, Jean Y.
    Dolman, Peter J.
    Ng, Tony L.
    Buffam, Frank V.
    White, Valerie A.
    OPHTHALMOLOGY, 2009, 116 (02) : 349 - 354
  • [29] Orbital floor repair using medpor porous polyethylene implants.
    Lupi, E
    Messi, M
    Ascani, G
    Balercia, P
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U504 - U504
  • [30] A COMPARISON OF MICROSCREW AND SUTURE FIXATION FOR POROUS HIGH-DENSITY POLYETHYLENE ORBITAL FLOOR IMPLANTS
    HAUG, RH
    KIMBERLY, D
    BRADRICK, JP
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1993, 51 (11) : 1217 - 1220