Comparison of Surgical Outcomes of Large Orbital Fractures Reconstructed With Porous Polyethylene Channel and Porous Polyethylene Titan Barrier Implants

被引:18
|
作者
Kim, Chang Yeom [1 ]
Jeong, Byung Jin [2 ]
Lee, Sang Yeul [1 ]
Yoon, Jin Sook [1 ]
机构
[1] Yonsei Univ, Coll Med, Inst Vis Res, Dept Ophthalmol, Seoul 120752, South Korea
[2] Cheil Eye Hosp, Div Oculoplasty, Taegu, South Korea
来源
关键词
MEDPOR; SURGERY;
D O I
10.1097/IOP.0b013e3182467c4a
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the postoperative outcomes of large orbital fractures repaired with porous polyethylene (PP) channel implants (PPCIs) and PP titan barrier implants (PPTBs). Methods: Medical records of 42 patients who underwent surgical reconstruction for a large orbital fracture with either PPCI or PPTB were reviewed retrospectively. The degree of diplopia, determined with a binocular single vision test, and enophthalmos, measured by a Hertel exophthalmometer, was compared between 2 implant groups. Orbital volumes were calculated using CT scans and the measuring tool. Results: Of the 42 patients examined, 16 received PPCI and 26 received PPTB. No significant difference in the degree of diplopia was observed between the 2 implant groups before surgery, and 1 and 3 months after surgery (p = 0.256, 0.408, and 0.432, respectively). Preoperative average enophthalmos measuring 1.28 mm and 1.04 mm was successfully corrected to 0.19 mm and 0.25 mm 3 months after reconstruction with PPCI and PPTB, respectively. The fractured orbit volumes and nonfractured contralateral orbit volumes were 24.96 +/- 2.32 cm(3) and 23.18 +/- 1.73 cm(3) in the PPCI group, and 26.80 +/- 2.10 cm(3) and 24.13 +/- 2.28 cm(3) in the PPTB group, respectively. After surgery, the fractured orbit volumes significantly decreased to 23.39 +/- 2.82 cm(3) in the PPCI group and to 23.53 +/- 1.74 cm(3) in the PPTB group; these values were not significantly different from that of the nonfractured orbit (p = 0.681 for PPCI and 0.204 for PPTB). Conclusions: Porous polyethylene channel implant and PPTB are both effective implant materials for the repair of large orbital fractures; however, PPTB has the additional benefit of not requiring screw fixation. (Ophthal Plast Reconstr Surg 2012;28:176-180)
引用
收藏
页码:176 / 180
页数:5
相关论文
共 50 条
  • [1] Porous polyethylene channel implants: A modified porous polyethylene sheet implant designed for repairs of large and complex orbital wall fractures
    Choi, JC
    Fleming, JC
    Aitken, PA
    Shore, JW
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 1999, 15 (01): : 56 - 66
  • [2] Repair of fractures of the orbital floor with porous polyethylene implants
    Yilmaz, Mustafa
    Vayvada, Haluk
    Aydin, Enver
    Menderes, Adnan
    Atabey, Atay
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2007, 45 (08): : 640 - 644
  • [3] Medial orbital wall reconstruction with a porous polyethylene titan barrier implant
    Ovchinsky, Alexander
    Cranford, Jeffrey P.
    ENT-EAR NOSE & THROAT JOURNAL, 2016, 95 (03) : 102 - 103
  • [4] Explanation of porous polyethylene orbital implants
    Boston, JD
    Weinberg, D
    Glasgow, B
    March, G
    Goldberg, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 585 - 585
  • [5] Integrated Orbital Implants-A Comparison of Hydroxyapatite and Porous Polyethylene Implants
    Sadiq, S. Ahmed
    Mengher, Lakbir S.
    Lowry, John
    Downes, Richard
    ORBIT-AN INTERNATIONAL JOURNAL ON ORBITAL DISORDERS AND FACIAL RECONSTRUCTIVE SURGERY, 2008, 27 (01): : 37 - 40
  • [6] Reconstruction of Orbital Floor Fractures with Porous Polyethylene Implants: A Prospective Study
    Sai Krishna D.
    Soumadip D.
    Journal of Maxillofacial and Oral Surgery, 2016, 15 (3) : 300 - 307
  • [7] COMPARISON OF FIBROVASCULAR INGROWTH INTO HYDROXYAPATITE AND POROUS POLYETHYLENE ORBITAL IMPLANTS
    RUBIN, PAD
    POPHAM, JK
    BILYK, JR
    SHORE, JW
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 1994, 10 (02): : 96 - 103
  • [8] A COMPARISON OF FIBROVASCULAR INGROWTH INTO HYDROXYAPATITE AND POROUS POLYETHYLENE ORBITAL IMPLANTS
    RUBIN, PAD
    POPHAM, JK
    SHORE, JW
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (04) : 1198 - 1198
  • [9] Evaluation of computer-based volume measurement and porous polyethylene channel implants in reconstruction of large orbital wall fractures
    Ye, J
    Kook, KH
    Lee, SY
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (02) : 509 - 513
  • [10] Porous polyethylene implants in orbital floor reconstruction
    Villarreal, PM
    Monje, F
    Morillo, AJ
    Junquera, LM
    González, C
    Barbón, JJ
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2002, 109 (03) : 877 - 885