Performance evaluation of disposable inhalable aerosol sampler at a copper electrorefinery

被引:4
|
作者
Lee, Eun Gyung [1 ]
Grimson, Peter J. [2 ]
Chisholm, William P. [1 ]
Kashon, Michael L. [3 ]
He, Xinjian [2 ]
L'Orange, Christian [4 ]
Volckens, John [4 ]
机构
[1] NIOSH, Hlth Effects Lab Div, Exposure Assessment Branch, 1095 Willowdale Rd, Morgantown, WV 26505 USA
[2] West Virginia Univ, Dept Ind & Management Syst Engn, Morgantown, WV 26506 USA
[3] NIOSH, Hlth Effects Lab Div, Biostat & Epidemiol Branch, Morgantown, WV USA
[4] Colorado State Univ, Dept Mech Engn, Ft Collins, CO 80523 USA
关键词
Copper electrorefinery; disposable inhalable aerosol sampler; exposure assessment; IOM sampler; sampling pairs; transportation loss; CONCORDANCE CORRELATION-COEFFICIENT; CASSETTE; AIR; AGREEMENT; CAPSULES; ISSUES;
D O I
10.1080/15459624.2019.1568444
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study evaluates the performance of the disposable inhalable aerosol sampler (DIAS), a new sampler developed to be more cost-effective than the traditional inhalable particle samplers and comparable to the inhalable particle sampling convention. Forty-eight pairs of the DIAS prototype and the IOM sampler were utilized to collect copper exposure measurements (23 personal and 25 area) at an electrorefinery facility. The geometric mean (GM) value of ratios of exposure data (DIAS/IOM) was 1.1, while the GM of ratios (DIAS/IOM) was 1.6 for the area exposure data, revealing 84% of the ratios were greater than one. For both personal and area exposure data, the concordance correlation coefficient tests revealed significant disagreements between the two types of samplers and suggested precision as the source of the disagreement. The estimated mean concentration was higher for the DIAS compared that for the IOM for the area exposure data (p < 0.05), while the results were comparable for the personal exposure data (p = 0.49). Overall, the DIAS generated higher exposure results compared to the IOM sampler for the area exposures. For the personal exposures, the findings were inconclusive due to inconsistent results of factors aforementioned. This study is limited to one metal component (copper) of the dust at a worksite. To date, this is the first field evaluation using personal exposure data to test the performance of the DIAS and the second evaluation using area exposure data. Thus, it will be necessary to conduct additional field evaluations with various elements to further evaluate the performance of the DIAS. In addition, particle migration to the internal walls of the cap was observed during the transportation of collected samples to a laboratory for both sampler types (6.4% for the DIAS and 7.4% for the IOM). Occupational health and safety professionals should be aware of potential errors caused from transferring samples from a field to a laboratory and should be careful not to exclude particles collected on the caps.
引用
收藏
页码:250 / 257
页数:8
相关论文
共 50 条
  • [41] Evaluation of personal inhalable aerosol samplers with different filters for use during anthrax responses
    Grinshpun, Sergey A.
    Weber, Angela M.
    Yermakov, Michael
    Indugula, Reshmi
    Elmashae, Yousef
    Reponen, Tiina
    Rose, Laura
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2017, 14 (08) : 583 - 593
  • [42] Use of numerical calculations to simulate the sampling efficiency performance of a personal aerosol sampler
    Bird, AJ
    AEROSOL SCIENCE AND TECHNOLOGY, 2005, 39 (07) : 596 - 610
  • [43] Evaluation of the physical performance of disposable isolation gowns
    Kilinc-Balci, F. Selcen
    AMERICAN JOURNAL OF INFECTION CONTROL, 2023, 51 (11) : 1201 - 1207
  • [44] A performance evaluation of the open tube diffusion sampler (Palmes sampler) for monitoring nitrogen dioxide
    De Santis, F
    Fino, A
    Tiwari, S
    Vazzana, C
    Allegrini, I
    AIR POLLUTION VIII, 2000, 8 : 421 - 429
  • [45] Performance evaluation of the portable MiniVOL particulate matter sampler
    Baldauf, RW
    Lane, DD
    Marotz, GA
    Wiener, RW
    ATMOSPHERIC ENVIRONMENT, 2001, 35 (35) : 6087 - 6091
  • [46] PERFORMANCE EVALUATION OF A SOLID SORBENT HYDROCARBON SAMPLER.
    Anon
    Electric Power Research Institute (Report) EPRI EA, 1979,
  • [47] A field evaluation of a single sampler for respirable and inhalable indium and dust measurements at an indium-tin oxide manufacturing facility
    Blackley, Brie Hawley
    Gibbs, Jenna L.
    Cummings, Kristin J.
    Stefaniak, Aleksandr B.
    Park, Ji Young
    Stanton, Marcia
    Virji, M. Abbas
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2019, 16 (01) : 66 - 77
  • [48] Development of PM0.1 Personal Sampler for Evaluation of Personal Exposure to Aerosol Nanoparticles
    Thongyen, Thunyapat
    Hata, Mitsuhiko
    Toriba, Akira
    Ikeda, Takuji
    Koyama, Hiromi
    Otani, Yoshio
    Furuuchi, Masami
    AEROSOL AND AIR QUALITY RESEARCH, 2015, 15 (01) : 180 - 187
  • [49] Development and laboratory evaluation of a compact swirling aerosol sampler (SAS) for collection of atmospheric bioaerosols
    Wubulihairen, Maimaitireyimu
    Lu, Xiaoying
    Lee, Patrick K. H.
    Ning, Zhi
    ATMOSPHERIC POLLUTION RESEARCH, 2015, 6 (04) : 556 - 561
  • [50] A numerical study of the performance of an aerosol sampler with a curved, blunt, multi-orificed inlet
    Gao, PF
    Chen, BT
    Baron, PA
    Soderholm, SC
    AEROSOL SCIENCE AND TECHNOLOGY, 2002, 36 (05) : 540 - 553