Performance evaluation of disposable inhalable aerosol sampler at a copper electrorefinery

被引:4
|
作者
Lee, Eun Gyung [1 ]
Grimson, Peter J. [2 ]
Chisholm, William P. [1 ]
Kashon, Michael L. [3 ]
He, Xinjian [2 ]
L'Orange, Christian [4 ]
Volckens, John [4 ]
机构
[1] NIOSH, Hlth Effects Lab Div, Exposure Assessment Branch, 1095 Willowdale Rd, Morgantown, WV 26505 USA
[2] West Virginia Univ, Dept Ind & Management Syst Engn, Morgantown, WV 26506 USA
[3] NIOSH, Hlth Effects Lab Div, Biostat & Epidemiol Branch, Morgantown, WV USA
[4] Colorado State Univ, Dept Mech Engn, Ft Collins, CO 80523 USA
关键词
Copper electrorefinery; disposable inhalable aerosol sampler; exposure assessment; IOM sampler; sampling pairs; transportation loss; CONCORDANCE CORRELATION-COEFFICIENT; CASSETTE; AIR; AGREEMENT; CAPSULES; ISSUES;
D O I
10.1080/15459624.2019.1568444
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study evaluates the performance of the disposable inhalable aerosol sampler (DIAS), a new sampler developed to be more cost-effective than the traditional inhalable particle samplers and comparable to the inhalable particle sampling convention. Forty-eight pairs of the DIAS prototype and the IOM sampler were utilized to collect copper exposure measurements (23 personal and 25 area) at an electrorefinery facility. The geometric mean (GM) value of ratios of exposure data (DIAS/IOM) was 1.1, while the GM of ratios (DIAS/IOM) was 1.6 for the area exposure data, revealing 84% of the ratios were greater than one. For both personal and area exposure data, the concordance correlation coefficient tests revealed significant disagreements between the two types of samplers and suggested precision as the source of the disagreement. The estimated mean concentration was higher for the DIAS compared that for the IOM for the area exposure data (p < 0.05), while the results were comparable for the personal exposure data (p = 0.49). Overall, the DIAS generated higher exposure results compared to the IOM sampler for the area exposures. For the personal exposures, the findings were inconclusive due to inconsistent results of factors aforementioned. This study is limited to one metal component (copper) of the dust at a worksite. To date, this is the first field evaluation using personal exposure data to test the performance of the DIAS and the second evaluation using area exposure data. Thus, it will be necessary to conduct additional field evaluations with various elements to further evaluate the performance of the DIAS. In addition, particle migration to the internal walls of the cap was observed during the transportation of collected samples to a laboratory for both sampler types (6.4% for the DIAS and 7.4% for the IOM). Occupational health and safety professionals should be aware of potential errors caused from transferring samples from a field to a laboratory and should be careful not to exclude particles collected on the caps.
引用
收藏
页码:250 / 257
页数:8
相关论文
共 50 条
  • [21] Relationship between indoor and outdoor bioaerosols collected with a button inhalable aerosol sampler in urban homes
    Lee, T
    Grinshpun, SA
    Martuzevicius, D
    Adhikari, A
    Crawford, CM
    Luo, J
    Reponen, T
    INDOOR AIR, 2006, 16 (01) : 37 - 47
  • [22] PERFORMANCE-CHARACTERISTICS OF MULTICYCLONE AEROSOL SAMPLER
    BLACHMAN, MW
    LIPPMANN, M
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1974, 35 (06): : 311 - 326
  • [23] Development and evaluation of an ultrasonic personal aerosol sampler
    Volckens, J.
    Quinn, C.
    Leith, D.
    Mehaffy, J.
    Henry, C. S.
    Miller-Lionberg, D.
    INDOOR AIR, 2017, 27 (02) : 409 - 416
  • [24] Performance evaluation of modified Semi-continuous Elements in Aerosol Sampler-III
    Pancras, Joseph Patrick
    Landis, Matthew S.
    ATMOSPHERIC ENVIRONMENT, 2011, 45 (37) : 6751 - 6759
  • [25] Inhalable Nanocomposite Microparticles with Enhanced Dissolution and Superior Aerosol Performance
    Zhu, Chune
    Chen, Jianting
    Yu, Shihui
    Que, Chailu
    Taylor, Lynne S.
    Tan, Wen
    Wu, Chuanbin
    Zhou, Qi Tony
    MOLECULAR PHARMACEUTICS, 2020, 17 (09) : 3270 - 3280
  • [26] LISA - A NEW AEROSOL GENERATION SYSTEM FOR SAMPLER EVALUATION
    CARSEY, TP
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1987, 48 (08): : 710 - 717
  • [27] Prototype Development and Laboratory Evaluation of an Aerosol to Hydrosol Sampler
    Wubulihairen, Maimaitireyimu
    Sabrina
    Jiang, Yanan
    Ning, Zhi
    AEROSOL AND AIR QUALITY RESEARCH, 2015, 15 (03) : 776 - 785
  • [28] Correlation between urinary 1-hydroxypyrene and ambient air pyrene measured with an inhalable aerosol sampler and a total dust sampler in an electrode paste plant
    Department of Toxicology, Natl. Inst. of Occupational Health, PO Box 8149 Dep., 0033 Oslo, Norway
    不详
    Sci. Total Environ., 1 (59-67):
  • [29] Correlation between urinary 1-hydroxypyrene and ambient air pyrene measured with an inhalable aerosol sampler and a total dust sampler in an electrode paste plant
    Bentsen, RK
    Halgard, K
    Noto, H
    Daae, HL
    Ovrebo, S
    SCIENCE OF THE TOTAL ENVIRONMENT, 1998, 212 (01) : 59 - 67
  • [30] Performance of prototype high-flow inhalable dust sampler in a livestock production facility
    Anthony, T. Renee
    Cai, Changjie
    Mehaffy, John
    Sleeth, Darrah
    Volckens, John
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2017, 14 (05) : 313 - 322