Performance evaluation of disposable inhalable aerosol sampler at a copper electrorefinery

被引:4
|
作者
Lee, Eun Gyung [1 ]
Grimson, Peter J. [2 ]
Chisholm, William P. [1 ]
Kashon, Michael L. [3 ]
He, Xinjian [2 ]
L'Orange, Christian [4 ]
Volckens, John [4 ]
机构
[1] NIOSH, Hlth Effects Lab Div, Exposure Assessment Branch, 1095 Willowdale Rd, Morgantown, WV 26505 USA
[2] West Virginia Univ, Dept Ind & Management Syst Engn, Morgantown, WV 26506 USA
[3] NIOSH, Hlth Effects Lab Div, Biostat & Epidemiol Branch, Morgantown, WV USA
[4] Colorado State Univ, Dept Mech Engn, Ft Collins, CO 80523 USA
关键词
Copper electrorefinery; disposable inhalable aerosol sampler; exposure assessment; IOM sampler; sampling pairs; transportation loss; CONCORDANCE CORRELATION-COEFFICIENT; CASSETTE; AIR; AGREEMENT; CAPSULES; ISSUES;
D O I
10.1080/15459624.2019.1568444
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study evaluates the performance of the disposable inhalable aerosol sampler (DIAS), a new sampler developed to be more cost-effective than the traditional inhalable particle samplers and comparable to the inhalable particle sampling convention. Forty-eight pairs of the DIAS prototype and the IOM sampler were utilized to collect copper exposure measurements (23 personal and 25 area) at an electrorefinery facility. The geometric mean (GM) value of ratios of exposure data (DIAS/IOM) was 1.1, while the GM of ratios (DIAS/IOM) was 1.6 for the area exposure data, revealing 84% of the ratios were greater than one. For both personal and area exposure data, the concordance correlation coefficient tests revealed significant disagreements between the two types of samplers and suggested precision as the source of the disagreement. The estimated mean concentration was higher for the DIAS compared that for the IOM for the area exposure data (p < 0.05), while the results were comparable for the personal exposure data (p = 0.49). Overall, the DIAS generated higher exposure results compared to the IOM sampler for the area exposures. For the personal exposures, the findings were inconclusive due to inconsistent results of factors aforementioned. This study is limited to one metal component (copper) of the dust at a worksite. To date, this is the first field evaluation using personal exposure data to test the performance of the DIAS and the second evaluation using area exposure data. Thus, it will be necessary to conduct additional field evaluations with various elements to further evaluate the performance of the DIAS. In addition, particle migration to the internal walls of the cap was observed during the transportation of collected samples to a laboratory for both sampler types (6.4% for the DIAS and 7.4% for the IOM). Occupational health and safety professionals should be aware of potential errors caused from transferring samples from a field to a laboratory and should be careful not to exclude particles collected on the caps.
引用
收藏
页码:250 / 257
页数:8
相关论文
共 50 条
  • [31] A Multidomain Magnetic Passive Aerosol Sampler: Development and Experimental Evaluation
    Hsiao, Ta-Chih
    Jaques, Peter A.
    Gao, Pengfei
    AEROSOL SCIENCE AND TECHNOLOGY, 2013, 47 (01) : 37 - 45
  • [32] Performance of personal inhalable aerosol samplers in very slowly moving air when facing the aerosol source
    Witschger, O
    Grinshpun, SA
    Fauvel, S
    Basso, G
    ANNALS OF OCCUPATIONAL HYGIENE, 2004, 48 (04): : 351 - 368
  • [33] In vitro evaluation of disposable transport ventilators with combination aerosol therapy
    Eain, Marc Mac Giolla
    O'Sullivan, Andrew
    Joyce, Mary
    MacLoughlin, Ronan
    BMJ OPEN RESPIRATORY RESEARCH, 2021, 8 (01)
  • [34] Performance of the RespiCon™ personal aerosol sampler in forest products industry workplaces
    Tatum, V
    Ray, AE
    Rovell-Rixx, D
    AIHAJ, 2002, 63 (03): : 311 - 316
  • [35] Experimental Evaluation of Oil Mists Using a Semivolatile Aerosol Dichotomous Sampler
    Kim, Seung Won
    Raynor, Peter C.
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2010, 7 (04) : 203 - 215
  • [36] DESIGN AND EVALUATION OF A HIGH-FLOW RATE DICHOTOMOUS AEROSOL SAMPLER
    HIGHSMITH, VR
    WEANT, CG
    ENVIRONMENT INTERNATIONAL, 1990, 16 (02) : 115 - 122
  • [37] BACTERIAL AEROSOL SAMPLERS .2. DEVELOPMENT AND EVALUATION OF THE SHIPE SAMPLER
    SHIPE, EL
    TYLER, ME
    CHAPMAN, DN
    APPLIED MICROBIOLOGY, 1959, 7 (06) : 349 - 354
  • [38] Performance of Spherical Aerosol Sampler in Low-Velocity Agriculture Environment
    Zaripov, S. K.
    Gilfanov, A. K.
    Mukhametzanov, I. T.
    INTERNATIONAL CONFERENCE ON AGRICULTURAL ENGINEERING: NEW TECHNOLOGIES FOR SUSTAINABLE AGRICULTURAL PRODUCTION AND FOOD SECURITY, 2014, 1054 : 333 - 339
  • [39] Performance characterization of the Radionuclide Aerosol Sampler/Analyzer air sampler during a high-activity release event
    Burnett, Jonathan L.
    Miley, Harry S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 985
  • [40] Performance Study of Personal Inhalable Aerosol Samplers at Ultra-Low Wind Speeds
    Sleeth, Darrah K.
    Vincent, James H.
    ANNALS OF OCCUPATIONAL HYGIENE, 2012, 56 (02): : 207 - 220