Ultrasonography Monitoring of Optic Nerve Sheath Diameter and Retinal Vessels in Patients with Cerebral Hemorrhage

被引:31
|
作者
Naldi, Andrea [1 ]
Pivetta, Emanuele [2 ,3 ,4 ,5 ]
Coppo, Lorenzo [6 ]
Cantello, Roberto [6 ]
Comi, Cristoforo [6 ]
Stecco, Alessandro [7 ]
Cerrato, Paolo [1 ]
Lesmeister, Martin [8 ]
Lochner, Piergiorgio [8 ]
机构
[1] City Hlth & Sci Univ Hosp Turin, Stroke Unit, Turin, Italy
[2] Univ Turin, Canc Epidemiol Unit, Dept Med Sci, Turin, Italy
[3] Univ Turin, CPO Unit, Dept Med Sci, Turin, Italy
[4] Univ Turin, Div Emergency Med, Dept Med Sci, Turin, Italy
[5] Univ Turin, High Dependency Unit, Dept Med Sci, Turin, Italy
[6] Univ Piemonte Orientale, Neurol Unit, Dept Translat Med, Novara, Italy
[7] Univ Piemonte Orientale, Neuroradiol Unit, Novara, Italy
[8] Saarland Univ, Dept Neurol, Med Ctr, Kirrberger Str 100, D-66421 Homburg, Germany
关键词
intracerebral hemorrhage; intracranial pressure; optic nerve sheath diameter; retinal vessels; TRANSCRANIAL DOPPLER ULTRASONOGRAPHY; RAISED INTRACRANIAL-PRESSURE; HYPERACUTE STAGE; SONOGRAPHY; PULSATILITY; ULTRASOUND; EYE;
D O I
10.1111/jon.12604
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE Evaluation of the diagnostic accuracy of optic nerve sheath diameter (ONSD) and Doppler indices of central retinal arteries and veins for the detection of increased intracranial pressure (ICP) in intracerebral hemorrhage (ICH) and of the usefulness of a second assessment of these variables in the monitoring of ICH. METHODS A total of 46 acute ICH patients with (group 1, n = 25) and without (group 2, n = 21) clinical and radiological computed tomography signs of raised ICP and 40 healthy controls were recruited. The median binocular ONSD and Doppler indices of retinal vessels including resistive index (RI) and retinal venous pulsation (RVP) were compared among groups, both at admission and later during ICH monitoring. RESULTS Median binocular ONSD showed higher accuracy for the detection of increased ICP (sensitivity and specificity 100%), while Doppler indices were less accurate (sensitivity 48% and specificity 95% for RI; 80% and 62% for RVP). In ICH patients, ONSD was significantly elevated in group 1 both at admission (6.40 mm [interquartile range [IQR] = .70] vs. 4.70 [.40]) and at control time (6.00 [.55] vs. 4.55 [.40]; P < .01), as well as RI (.79 [.11] vs. .77 [.03] and .80 [.06] vs. .75 [.35]; P = .01). RVP was significantly increased in group 1 only at admission (3.20 cm/s [1.05] vs. 2.00 [1.55], P = .02). CONCLUSIONS Median binocular ONSD evaluation showed higher accuracy for the estimation of elevated ICP compared with Doppler indices of retinal vessels. The ONSD enlargement detected in the early phase of ICH persists at control time.
引用
收藏
页码:394 / 399
页数:6
相关论文
共 50 条
  • [41] Optic nerve sheath diameter and ICP
    不详
    PEDIATRIC RESEARCH, 2017, 81 (03) : 393 - 393
  • [42] Sonography of the Optic Nerve Sheath Diameter
    De Bernardo, Maddalena
    Marotta, Giuseppe
    Rosa, Nicola
    JOURNAL OF ULTRASOUND IN MEDICINE, 2018, 37 (07) : 1845 - 1845
  • [43] Research trends in optic nerve sheath diameter monitoring - A bibliometric study
    Magoon, Rohan
    Jose, Jes
    Suresh, Varun
    INDIAN JOURNAL OF ANAESTHESIA, 2024, 68 (06) : 579 - 582
  • [44] Post-craniotomy intracranial pressure monitoring: a novel approach combining optic nerve sheath diameter ultrasonography and cervical-cerebral arterial ultrasound
    Fu, Zunfeng
    Peng, Lin
    Guo, Laicai
    Hu, Naixia
    Zhu, Yamin
    Tang, Shouxin
    Lou, Hongliang
    Zhang, Jiajun
    Wang, Chongqiang
    FRONTIERS IN NEUROLOGY, 2025, 15
  • [45] Correlation Between Ultrasonographic Optic Nerve Sheath Diameter and Intracranial Pressure in Patients with Aneurysmal Subarachnoid Hemorrhage
    Varun Suresh
    Saurabh Sharma
    Anurag Aggarwal
    Neurocritical Care, 2020, 33 : 860 - 861
  • [46] Correlation Between Ultrasonographic Optic Nerve Sheath Diameter and Intracranial Pressure in Patients with Aneurysmal Subarachnoid Hemorrhage
    Suresh, Varun
    Sharma, Saurabh
    Aggarwal, Anurag
    NEUROCRITICAL CARE, 2020, 33 (03) : 860 - 861
  • [47] The Authors Reply: Is Optic Nerve Sheath Diameter a Reliable Proxy for Intracranial Pressure in Patients with Subarachnoid Hemorrhage?
    Zoerle, Tommaso
    Stocchetti, Nino
    NEUROCRITICAL CARE, 2020, 33 (02) : 621 - 622
  • [48] The Authors Reply: Is Optic Nerve Sheath Diameter a Reliable Proxy for Intracranial Pressure in Patients with Subarachnoid Hemorrhage?
    Tommaso Zoerle
    Nino Stocchetti
    Neurocritical Care, 2020, 33 : 621 - 622
  • [49] Bedside Ultrasonography as an Alternative to Computed Tomography Scan for the Measurement of Optic Nerve Sheath Diameter
    Yanamandra, Uday
    Gupta, Amul
    Yanamandra, Sushma
    Das, Subrat Kumar
    Patyal, Sagarika
    Nair, Velu
    JOURNAL OF NEUROSCIENCES IN RURAL PRACTICE, 2018, 9 (02) : 252 - 255
  • [50] Comparison of Optic Nerve Sheath Diameter between both eyes: A Bedside Ultrasonography Approach
    Yanamandra, Uday
    Gupta, Amul
    Bhattachar, Srinivasa A.
    Yanamandra, Sushma
    Das, Subrat K.
    Patyal, Sagarika
    Grewal, Rajan
    Nair, Velu
    INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2018, 22 (03) : 150 - 153