Ultrasonography Monitoring of Optic Nerve Sheath Diameter and Retinal Vessels in Patients with Cerebral Hemorrhage

被引:31
|
作者
Naldi, Andrea [1 ]
Pivetta, Emanuele [2 ,3 ,4 ,5 ]
Coppo, Lorenzo [6 ]
Cantello, Roberto [6 ]
Comi, Cristoforo [6 ]
Stecco, Alessandro [7 ]
Cerrato, Paolo [1 ]
Lesmeister, Martin [8 ]
Lochner, Piergiorgio [8 ]
机构
[1] City Hlth & Sci Univ Hosp Turin, Stroke Unit, Turin, Italy
[2] Univ Turin, Canc Epidemiol Unit, Dept Med Sci, Turin, Italy
[3] Univ Turin, CPO Unit, Dept Med Sci, Turin, Italy
[4] Univ Turin, Div Emergency Med, Dept Med Sci, Turin, Italy
[5] Univ Turin, High Dependency Unit, Dept Med Sci, Turin, Italy
[6] Univ Piemonte Orientale, Neurol Unit, Dept Translat Med, Novara, Italy
[7] Univ Piemonte Orientale, Neuroradiol Unit, Novara, Italy
[8] Saarland Univ, Dept Neurol, Med Ctr, Kirrberger Str 100, D-66421 Homburg, Germany
关键词
intracerebral hemorrhage; intracranial pressure; optic nerve sheath diameter; retinal vessels; TRANSCRANIAL DOPPLER ULTRASONOGRAPHY; RAISED INTRACRANIAL-PRESSURE; HYPERACUTE STAGE; SONOGRAPHY; PULSATILITY; ULTRASOUND; EYE;
D O I
10.1111/jon.12604
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE Evaluation of the diagnostic accuracy of optic nerve sheath diameter (ONSD) and Doppler indices of central retinal arteries and veins for the detection of increased intracranial pressure (ICP) in intracerebral hemorrhage (ICH) and of the usefulness of a second assessment of these variables in the monitoring of ICH. METHODS A total of 46 acute ICH patients with (group 1, n = 25) and without (group 2, n = 21) clinical and radiological computed tomography signs of raised ICP and 40 healthy controls were recruited. The median binocular ONSD and Doppler indices of retinal vessels including resistive index (RI) and retinal venous pulsation (RVP) were compared among groups, both at admission and later during ICH monitoring. RESULTS Median binocular ONSD showed higher accuracy for the detection of increased ICP (sensitivity and specificity 100%), while Doppler indices were less accurate (sensitivity 48% and specificity 95% for RI; 80% and 62% for RVP). In ICH patients, ONSD was significantly elevated in group 1 both at admission (6.40 mm [interquartile range [IQR] = .70] vs. 4.70 [.40]) and at control time (6.00 [.55] vs. 4.55 [.40]; P < .01), as well as RI (.79 [.11] vs. .77 [.03] and .80 [.06] vs. .75 [.35]; P = .01). RVP was significantly increased in group 1 only at admission (3.20 cm/s [1.05] vs. 2.00 [1.55], P = .02). CONCLUSIONS Median binocular ONSD evaluation showed higher accuracy for the estimation of elevated ICP compared with Doppler indices of retinal vessels. The ONSD enlargement detected in the early phase of ICH persists at control time.
引用
收藏
页码:394 / 399
页数:6
相关论文
共 50 条
  • [21] Optic nerve sheath diameter sonography during the acute stage of intracerebral hemorrhage: a potential role in monitoring neurocritical patients
    Bender, M.
    Lakicevic, S.
    Pravdic, N.
    Schreiber, S.
    Malojcic, B.
    ULTRASOUND JOURNAL, 2020, 12 (01):
  • [22] Optic nerve sheath diameter sonography during the acute stage of intracerebral hemorrhage: a potential role in monitoring neurocritical patients
    M. Bender
    S. Lakicevic
    N. Pravdic
    S. Schreiber
    B. Malojcic
    The Ultrasound Journal, 12
  • [23] Optic nerve sheath diameter
    Lovrencic-Huzjan, A.
    CEREBROVASCULAR DISEASES, 2015, 39 : 4 - 4
  • [24] Measuring Optic Nerve Sheath Diameter with Bedside Ocular Ultrasonography in Patients with Carbon Monoxide Poisoning
    Kaya, Halil
    Bas, Esra Askin
    Engindeniz, Zulfi
    Gafurogullari, Sibel
    Durmaz, Dilek
    Kaynak, Mahmut Firat
    PUERTO RICO HEALTH SCIENCES JOURNAL, 2021, 40 (04) : 180 - 184
  • [25] Comment on "Measuring optic nerve sheath diameter using ultrasonography in patients with idiopathic intracranial hypertension"
    De Luca, Martina
    Biondino, Danilo
    Gioia, Marco
    La Marca, Aniello
    ARQUIVOS DE NEURO-PSIQUIATRIA, 2023, 81 (06) : 610 - 611
  • [26] Correlation between cerebral biomarkers and optic nerve sheath diameter in patients with severe preeclampsia
    Brzan Simenc, Gabrijela
    Ambrozic, Jana
    Osredkar, Josko
    Gersak, Ksenija
    Lucovnik, Miha
    HYPERTENSION IN PREGNANCY, 2021, 40 (01) : 9 - 14
  • [27] OPTIC NERVE SHEATH HEMORRHAGE
    MANSCHOT, WA
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1951, 34 (09) : 1335 - 1336
  • [28] OPTIC NERVE SHEATH HEMORRHAGE
    WALSH, FB
    HEDGES, TR
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1951, 34 (04) : 509 - 527
  • [29] Optic nerve sheath diameter in patients with hepatic encephalopathy
    Colak, Nese
    Basakci, Ozlem Bayrak
    Bayram, Basak
    Aksay, Ersin
    Simsek, Muhammet Kursat
    Karabay, Nuri
    PLOS ONE, 2022, 17 (11):
  • [30] Determination of normal values of optic nerve sheath diameter in newborns with bedside ultrasonography
    Yapicioglu, Hacer
    Aslan, Nagehan
    Sertdemir, Yasar
    Yildizdas, Dincer
    Gulasi, Selvi
    Mert, Kurthan
    EARLY HUMAN DEVELOPMENT, 2020, 145