Ultrasonography Monitoring of Optic Nerve Sheath Diameter and Retinal Vessels in Patients with Cerebral Hemorrhage

被引:31
|
作者
Naldi, Andrea [1 ]
Pivetta, Emanuele [2 ,3 ,4 ,5 ]
Coppo, Lorenzo [6 ]
Cantello, Roberto [6 ]
Comi, Cristoforo [6 ]
Stecco, Alessandro [7 ]
Cerrato, Paolo [1 ]
Lesmeister, Martin [8 ]
Lochner, Piergiorgio [8 ]
机构
[1] City Hlth & Sci Univ Hosp Turin, Stroke Unit, Turin, Italy
[2] Univ Turin, Canc Epidemiol Unit, Dept Med Sci, Turin, Italy
[3] Univ Turin, CPO Unit, Dept Med Sci, Turin, Italy
[4] Univ Turin, Div Emergency Med, Dept Med Sci, Turin, Italy
[5] Univ Turin, High Dependency Unit, Dept Med Sci, Turin, Italy
[6] Univ Piemonte Orientale, Neurol Unit, Dept Translat Med, Novara, Italy
[7] Univ Piemonte Orientale, Neuroradiol Unit, Novara, Italy
[8] Saarland Univ, Dept Neurol, Med Ctr, Kirrberger Str 100, D-66421 Homburg, Germany
关键词
intracerebral hemorrhage; intracranial pressure; optic nerve sheath diameter; retinal vessels; TRANSCRANIAL DOPPLER ULTRASONOGRAPHY; RAISED INTRACRANIAL-PRESSURE; HYPERACUTE STAGE; SONOGRAPHY; PULSATILITY; ULTRASOUND; EYE;
D O I
10.1111/jon.12604
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE Evaluation of the diagnostic accuracy of optic nerve sheath diameter (ONSD) and Doppler indices of central retinal arteries and veins for the detection of increased intracranial pressure (ICP) in intracerebral hemorrhage (ICH) and of the usefulness of a second assessment of these variables in the monitoring of ICH. METHODS A total of 46 acute ICH patients with (group 1, n = 25) and without (group 2, n = 21) clinical and radiological computed tomography signs of raised ICP and 40 healthy controls were recruited. The median binocular ONSD and Doppler indices of retinal vessels including resistive index (RI) and retinal venous pulsation (RVP) were compared among groups, both at admission and later during ICH monitoring. RESULTS Median binocular ONSD showed higher accuracy for the detection of increased ICP (sensitivity and specificity 100%), while Doppler indices were less accurate (sensitivity 48% and specificity 95% for RI; 80% and 62% for RVP). In ICH patients, ONSD was significantly elevated in group 1 both at admission (6.40 mm [interquartile range [IQR] = .70] vs. 4.70 [.40]) and at control time (6.00 [.55] vs. 4.55 [.40]; P < .01), as well as RI (.79 [.11] vs. .77 [.03] and .80 [.06] vs. .75 [.35]; P = .01). RVP was significantly increased in group 1 only at admission (3.20 cm/s [1.05] vs. 2.00 [1.55], P = .02). CONCLUSIONS Median binocular ONSD evaluation showed higher accuracy for the estimation of elevated ICP compared with Doppler indices of retinal vessels. The ONSD enlargement detected in the early phase of ICH persists at control time.
引用
收藏
页码:394 / 399
页数:6
相关论文
共 50 条
  • [31] Correlation Between Optic Nerve Sheath Diameter and Intracranial Pressure Based on Ultrasonography
    Pan, Nifang
    Xie, Jie
    He, Jian
    Wen, Shun
    Xu, Chunyang
    Zheng, Feng
    Ye, Hongwei
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2021, 11 (01) : 241 - 246
  • [32] Optic Nerve Sheath Diameter Point-of-Care Ultrasonography Quality Criteria Checklist: An International Consensus Statement on Optic Nerve Sheath Diameter Imaging and Measurement
    Hirzallah, Mohammad I.
    Lochner, Piergiorgio
    Hafeez, Muhammad Ubaid
    Lee, Andrew G.
    Krogias, Christos
    Dongarwar, Deepa
    Hartman, Nicholas D.
    Ertl, Michael
    Robba, Chiara
    Malojcic, Branko
    Valaikiene, Jurgita
    Sarwal, Aarti
    Hakimi, Ryan
    Schlachetzki, Felix
    CRITICAL CARE MEDICINE, 2024, 52 (10) : 1543 - 1556
  • [33] Knowledge, attitude, and practices of paramedics regarding optic nerve sheath diameter ultrasonography
    Szarpak, Lukasz
    Truszewski, Zenon
    Kurowski, Andrzej
    Samarin, Silvia
    Evrin, Togay
    Adamczyk, Piotr
    Czyzewski, Lukasz
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2016, 34 (06): : 1160 - 1161
  • [34] EFFECT OF CERVICAL SYMPATHETIC BLOCK ON OPTIC NERVE SHEATH DIAMETER MEASURED BY ULTRASONOGRAPHY
    Kim, Min-Soo
    Yoon, Kyung Bong
    Yoon, Duck Mi
    Kim, Do-Hyeong
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (06): : 1599 - 1604
  • [35] OPTIC-NERVE SHEATH AND THE PATHOGENESIS OF PAPILLARY EDEMA AND RETINAL HEMORRHAGE
    VERDIE, JC
    LAZORTHES, G
    REVUE DE MEDECINE DE TOULOUSE, 1979, 15 (08): : 485 - 488
  • [36] Comparison of pre/postoperative variations in Optic Nerve Sheath Diameter measured by Transbulbar Ultrasonography in Neurosurgical patients
    Suresh, Varun
    ANESTHESIA AND ANALGESIA, 2021, 133 (3S_SUPPL): : 1010 - 1010
  • [37] Is the Optic Nerve Sheath Diameter That is by Ultrasonography Useful for Early Detection of Elevated Intracranial Pressure in Adult Patients?
    Oh, S.
    Kim, S.
    ANNALS OF EMERGENCY MEDICINE, 2008, 52 (04) : S129 - S129
  • [38] The clinical and prognostic values of optic nerve sheath diameter and optic nerve sheath diameter/eyeball transverse diameter ratio in comatose patients with supratentorial lesions
    Sha Zhu
    Chao Cheng
    Dianjiang Zhao
    Yuanli Zhao
    Xianzeng Liu
    Jun Zhang
    BMC Neurology, 21
  • [39] The clinical and prognostic values of optic nerve sheath diameter and optic nerve sheath diameter/eyeball transverse diameter ratio in comatose patients with supratentorial lesions
    Zhu, Sha
    Cheng, Chao
    Zhao, Dianjiang
    Zhao, Yuanli
    Liu, Xianzeng
    Zhang, Jun
    BMC NEUROLOGY, 2021, 21 (01)
  • [40] Measuring the Optic Nerve Sheath Diameter with Ultrasound in Acute Middle Cerebral Artery Stroke Patients
    Guzeldag, Seda
    Yilmaz, Gokhan
    Tuna, Merva
    Altuntas, Mukerrem
    Ozdemir, Mustafa
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2021, 30 (02):