The reliability of computed tomography (CT) values and dimensional measurements of the oropharyngeal region using cone beam CT: comparison with multidetector CT

被引:89
|
作者
Yamashina, A. [1 ]
Tanimoto, K. [1 ]
Sutthiprapaporn, P. [1 ,2 ]
Hayakawa, Y. [3 ]
机构
[1] Hiroshima Univ, Grad Sch Biomed Sci, Dept Oral & Maxillofacial Surg, Hiroshima 730, Japan
[2] Khon Kaen Univ, Fac Dent, Dept Oral Diag, Khon Kaen, Thailand
[3] Kitami Inst Technol, Fac Engn, Dept Comp Sci, Kitami, Hokkaido, Japan
关键词
computed tomography; cone beam; computed tomography value; oropharynx;
D O I
10.1259/dmfr/45926904
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To evaluate the reliability of cone beam CT (CBCT) values and dimensional measurements of oropharyngeal air spaces as compared with those of multidetector row CT (MDCT). Methods: A soft tissue equivalent phantom with different sized holes was used. The phantom was scanned using CBCT and MDCT. In addition, a volunteer was examined using both methods for clinical comparison. The CT data were retrieved to a personal computer and treated using image processing software for three-dimensional rendering and dimensional measurements. The CT values of air, water and soft tissues were measured experimentally and the CT values of air, fat and muscle were measured in a clinical case. The diameter of each hole drilled in the phantom was measured on CBCT and MDCT images using the software tool and digimatic callipers. Results: The CBCT values were quite different from the Hounsfield units obtained with a typical MDCT system. The standard deviations were almost ten times larger with CBCT. In vivo assessment showed that the CBCT values for fat had a wide range that partially overlapped the values for muscle. The measurement of distances greater than 4 mm was consistent for all methods. The difference for holes was less than 0.2 mm. Conclusions: The phantom study showed that CBCT provides limited quantitative CT values for each pixel on sliced images for differentiating air, water and soft tissues. However, the measurement of air spaces with CBCT was quite accurate.
引用
收藏
页码:245 / 251
页数:7
相关论文
共 50 条
  • [1] Bone Densitometric Analysis using Cone Beam Computed Tomography (Cone Beam CT) and Computed Tomography (CT): Establishing the Correlation between Predicted and Actual Values
    Kumar, Rashmit
    Punnoose, Kurian
    Chikkanna, Meenakumari
    Gunturu, Srikanth
    Alrifai, Mosa Mohammad
    Al Zahrani, Abdulghani Saeed
    Babu, J. Suresh
    Swarnalatha, C.
    Nayyar, Abhishek Singh
    ADVANCED BIOMEDICAL RESEARCH, 2025, 14 (01):
  • [2] Accuracy of linear intraoral measurements using cone beam CT and multidetector CT: methodological mistake
    Sabour, S.
    Kermani, H.
    DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (04)
  • [3] Accuracy of linear intraoral measurements using cone beam CT and multidetector CT: a tale of two CTs
    Patcas, R.
    Markic, G.
    Mueller, L.
    Ullrich, O.
    Peltomaki, T.
    Kellenberger, C. J.
    Karlo, C. A.
    DENTOMAXILLOFACIAL RADIOLOGY, 2012, 41 (08) : 637 - 644
  • [4] A Feasibility Study of Using Computed Tomography (CT) and Cone Beam CT Simultaneously for Radiomics Analysis
    Luo, R.
    Wang, J.
    Zhong, H.
    Gan, J.
    Zhou, Z.
    Hu, P.
    Shen, L.
    Xia, F.
    Zhou, M.
    Hu, W.
    Zhang, Z.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E656 - E656
  • [6] A comparison of a new limited cone beam computed tomography machine for dental use with a multidetector row helical CT machine
    Hashimoto, K
    Arai, Y
    Iwai, K
    Araki, M
    Kawashima, S
    Terakado, M
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2003, 95 (03): : 371 - 377
  • [7] Accuracy and reliability of different cone beam computed tomography (CBCT) devices for structural analysis of alveolar bone in comparison with multislice CT and micro-CT
    Van Dessel, Jeroen
    Nicolielo, Laura Ferreira Pinheiro
    Huang, Yan
    Coudyzer, Walter
    Salmon, Benjamin
    Lambrichts, Ivo
    Jacobs, Reinhilde
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2017, 10 (01) : 95 - 105
  • [8] Comparison of cone-beam (CB) reconstruction algorithms in spiral computed tomography (CT)
    Sourbelle, K
    Lauritsch, G
    Tam, KC
    Kachelriess, M
    Kalender, WA
    RADIOLOGY, 2002, 225 : 253 - 253
  • [9] A comparative study of the accuracy and reliability of multidetector CT and cone beam CT in the assessment of dental implant site dimensions
    Kamburoglu, K.
    Yuksel, S.
    DENTOMAXILLOFACIAL RADIOLOGY, 2011, 40 (07) : 466 - 467
  • [10] Comparison of HU-values of a cone beam computed tomography scan mode with the scan mode of a conventional CT scanner
    Wagner, D. M.
    Vorwerk, H.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2010, 186 : 82 - 83