Bone Densitometric Analysis using Cone Beam Computed Tomography (Cone Beam CT) and Computed Tomography (CT): Establishing the Correlation between Predicted and Actual Values

被引:0
|
作者
Kumar, Rashmit [1 ]
Punnoose, Kurian [2 ]
Chikkanna, Meenakumari [3 ]
Gunturu, Srikanth [4 ]
Alrifai, Mosa Mohammad [5 ]
Al Zahrani, Abdulghani Saeed [6 ]
Babu, J. Suresh [7 ]
Swarnalatha, C. [7 ]
Nayyar, Abhishek Singh [8 ,9 ]
机构
[1] Vananchal Dent Coll & Hosp, Dept Oral Med & Radiol, Garhwa, Jharkhand, India
[2] Univ Hail, Coll Dent, Dept Oral & Maxillofacial Surg, Hail, Saudi Arabia
[3] Majmaah Univ, Coll Dent, Dept Dent Restorat & Prosthodont, Al Majmaah, Saudi Arabia
[4] Drs Sudha & Nageswara Rao Siddhartha Inst Dent Sci, Dept Oral & Maxillofacial Surg, Gannavaram, Andhra Pradesh, India
[5] King Fahad Hosp, Dent Ctr, Sultanah, Al Madinah Al Munawarah, Madinah, Saudi Arabia
[6] Al Nuayriyah Gen Hosp, Dept Restorat Dent Sci, Nuayriyah, Dammam, Eastern Provinc, Saudi Arabia
[7] Univ Hail, Coll Dent, Dept Prevent Dent Sci, Div Periodontol, Hail, Saudi Arabia
[8] Saraswati Dhanwantari Dent Coll & Hosp, Dept Oral Med & Radiol, Parbhani, Maharashtra, India
[9] Post Grad Res Inst, Parbhani, Maharashtra, India
来源
ADVANCED BIOMEDICAL RESEARCH | 2025年 / 14卷 / 01期
关键词
Bone density; computed tomography (CT); cone beam computed tomography (cone beam CT); in-vitro study; MINERAL DENSITY; VOXEL VALUES; MULTISLICE; ACCURACY; CBCT;
D O I
10.4103/abr.abr_313_24
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background:One of the major drawbacks of cone beam computed tomography (cone beam CT) is that unlike CT, the gray density values obtained from cone beam CT are relative, and not absolute as obtained in the case of CT. The present study was conducted with the intent to perform a comparative bone densitometric analysis using cone beam CT and CT and to determine if there was a mathematical correlation between the two. Materials and Methods:The present in-vitro study included CT and cone beam CT scans of 30 dry mandibles wherein the gray density values from well-demarcated, precise anatomical areas were obtained, analyzed, and compared. Also, the dependent t-test and Pearson's correlation coefficient test were used for statistical analysis, while probability values (P values) < 0.05 were contemplated as being statistically significant. Results:Pearson's correlation between the gray density values for different combinations of point(s)/group(s) as derived on CT and cone beam CT images revealed the results to be statistically significant for each of the imaging methods used, individually and when compared in between the two methods, in all the cases (P < 0.001) when analyzed at 5% level of significance. Conclusions:The mean gray density values obtained with cone beam CT were found to be significantly higher than the ones derived from CT in the present study, though, a linear correlation was observed between the values obtained from cone beam CT and CT, which can be used to convert the relative values obtained with cone beam CT into absolute values derived with CT.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Correlation between gray values in cone-beam computed tomography and histomorphometric analysis
    Anbiaee, Najmeh
    Shafieian, Reihaneh
    Shiezadeh, Farid
    Shakeri, Mohammadtaghi
    Naqipour, Fatemeh
    IMAGING SCIENCE IN DENTISTRY, 2022, 52 (04) : 375 - 382
  • [2] A Feasibility Study of Using Computed Tomography (CT) and Cone Beam CT Simultaneously for Radiomics Analysis
    Luo, R.
    Wang, J.
    Zhong, H.
    Gan, J.
    Zhou, Z.
    Hu, P.
    Shen, L.
    Xia, F.
    Zhou, M.
    Hu, W.
    Zhang, Z.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E656 - E656
  • [3] Cone-Beam Computed Tomography (CBCT) to Computed Tomography (CT) Image Translation with Perceptual Loss to Eliminate Cone-Beam Artifacts
    Yoo, S.
    Choi, B.
    Park, I.
    Kim, J.
    Kim, H.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [4] Influence of anatomical location on CT numbers in cone beam computed tomography
    Oliveira, Matheus L.
    Tosoni, Guilherme M.
    Lindsey, David H.
    Mendoza, Kristopher
    Tetradis, Sotirios
    Mallya, Sanjay M.
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2013, 115 (04): : 558 - 564
  • [5] The reliability of computed tomography (CT) values and dimensional measurements of the oropharyngeal region using cone beam CT: comparison with multidetector CT
    Yamashina, A.
    Tanimoto, K.
    Sutthiprapaporn, P.
    Hayakawa, Y.
    DENTOMAXILLOFACIAL RADIOLOGY, 2008, 37 (05) : 245 - 251
  • [6] Evaluation of the zygomatic bone by cone beam computed tomography
    Ribeiro Nascimento, Helena Aguiar
    Portella Guedes Visconti, Maria Augusta
    Silva Macedo, Paulo de Tarso
    Haiter-Neto, Francisco
    Freitas, Deborah Queiroz
    SURGICAL AND RADIOLOGIC ANATOMY, 2015, 37 (01) : 55 - 60
  • [7] Evaluation of the zygomatic bone by cone beam computed tomography
    Helena Aguiar Ribeiro Nascimento
    Maria Augusta Portella Guedes Visconti
    Paulo de Tarso Silva Macedo
    Francisco Haiter-Neto
    Deborah Queiroz Freitas
    Surgical and Radiologic Anatomy, 2015, 37 : 55 - 60
  • [8] Cone beam computed tomography in endodontics
    Jasem Greval
    British Dental Journal, 2019, 226 (2) : 92 - 92
  • [9] Panoramic cone beam computed tomography
    Chang, Jenghwa
    Zhou, Lili
    Wang, Song
    Chao, K. S. Clifford
    MEDICAL PHYSICS, 2012, 39 (05) : 2930 - 2946
  • [10] Cone beam computed tomography in Endodontics
    D'Addazio, P. S. S.
    Carvalho, A. C. P.
    Campos, C. N.
    Devito, K. L.
    Ozcan, M.
    INTERNATIONAL ENDODONTIC JOURNAL, 2016, 49 (03) : 311 - 312