Bone Densitometric Analysis using Cone Beam Computed Tomography (Cone Beam CT) and Computed Tomography (CT): Establishing the Correlation between Predicted and Actual Values

被引:0
|
作者
Kumar, Rashmit [1 ]
Punnoose, Kurian [2 ]
Chikkanna, Meenakumari [3 ]
Gunturu, Srikanth [4 ]
Alrifai, Mosa Mohammad [5 ]
Al Zahrani, Abdulghani Saeed [6 ]
Babu, J. Suresh [7 ]
Swarnalatha, C. [7 ]
Nayyar, Abhishek Singh [8 ,9 ]
机构
[1] Vananchal Dent Coll & Hosp, Dept Oral Med & Radiol, Garhwa, Jharkhand, India
[2] Univ Hail, Coll Dent, Dept Oral & Maxillofacial Surg, Hail, Saudi Arabia
[3] Majmaah Univ, Coll Dent, Dept Dent Restorat & Prosthodont, Al Majmaah, Saudi Arabia
[4] Drs Sudha & Nageswara Rao Siddhartha Inst Dent Sci, Dept Oral & Maxillofacial Surg, Gannavaram, Andhra Pradesh, India
[5] King Fahad Hosp, Dent Ctr, Sultanah, Al Madinah Al Munawarah, Madinah, Saudi Arabia
[6] Al Nuayriyah Gen Hosp, Dept Restorat Dent Sci, Nuayriyah, Dammam, Eastern Provinc, Saudi Arabia
[7] Univ Hail, Coll Dent, Dept Prevent Dent Sci, Div Periodontol, Hail, Saudi Arabia
[8] Saraswati Dhanwantari Dent Coll & Hosp, Dept Oral Med & Radiol, Parbhani, Maharashtra, India
[9] Post Grad Res Inst, Parbhani, Maharashtra, India
来源
ADVANCED BIOMEDICAL RESEARCH | 2025年 / 14卷 / 01期
关键词
Bone density; computed tomography (CT); cone beam computed tomography (cone beam CT); in-vitro study; MINERAL DENSITY; VOXEL VALUES; MULTISLICE; ACCURACY; CBCT;
D O I
10.4103/abr.abr_313_24
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background:One of the major drawbacks of cone beam computed tomography (cone beam CT) is that unlike CT, the gray density values obtained from cone beam CT are relative, and not absolute as obtained in the case of CT. The present study was conducted with the intent to perform a comparative bone densitometric analysis using cone beam CT and CT and to determine if there was a mathematical correlation between the two. Materials and Methods:The present in-vitro study included CT and cone beam CT scans of 30 dry mandibles wherein the gray density values from well-demarcated, precise anatomical areas were obtained, analyzed, and compared. Also, the dependent t-test and Pearson's correlation coefficient test were used for statistical analysis, while probability values (P values) < 0.05 were contemplated as being statistically significant. Results:Pearson's correlation between the gray density values for different combinations of point(s)/group(s) as derived on CT and cone beam CT images revealed the results to be statistically significant for each of the imaging methods used, individually and when compared in between the two methods, in all the cases (P < 0.001) when analyzed at 5% level of significance. Conclusions:The mean gray density values obtained with cone beam CT were found to be significantly higher than the ones derived from CT in the present study, though, a linear correlation was observed between the values obtained from cone beam CT and CT, which can be used to convert the relative values obtained with cone beam CT into absolute values derived with CT.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] A DOSIMETRIC EVALUATION OF CONE BEAM COMPUTED TOMOGRAPHY
    Alkhatib, H.
    Stenbeck, J.
    Higgins, P.
    Alaei, P.
    Tedeschi, D.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S478 - S479
  • [32] Skeletal Dosimetry in Cone Beam Computed Tomography
    Kawrakow, I.
    Walters, B.
    Kramer, R.
    Ding, G.
    MEDICAL PHYSICS, 2008, 35 (06) : 2958 - +
  • [33] Cone beam computed tomography in Endodontics - a review
    Patel, S.
    Durack, C.
    Abella, F.
    Shemesh, H.
    Roig, M.
    Lemberg, K.
    INTERNATIONAL ENDODONTIC JOURNAL, 2015, 48 (01) : 3 - 15
  • [34] Skeletal dosimetry in cone beam computed tomography
    Walters, B. R. B.
    Ding, G. X.
    Kramer, R.
    Kawrakow, I.
    MEDICAL PHYSICS, 2009, 36 (07) : 2915 - 2922
  • [35] Use of cone beam computed tomography in periodontology
    Acar, Buket
    Kamburoglu, Kivanc
    WORLD JOURNAL OF RADIOLOGY, 2014, 6 (05): : 139 - 147
  • [36] Cone beam computed tomography use in orthodontics
    Nervina, J. M.
    AUSTRALIAN DENTAL JOURNAL, 2012, 57 : 95 - 102
  • [37] ICRP 129 and cone beam computed tomography
    Geist, James R.
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2016, 121 (04): : 345 - 347
  • [38] Use of Cone Beam Computed Tomography in Endodontics
    Scarfe, William C.
    Levin, Martin D.
    Gane, David
    Farman, Allan G.
    INTERNATIONAL JOURNAL OF DENTISTRY, 2009, 2009
  • [39] Cone-Beam Computed Tomography in Orthodontics
    Abdelkarim, Ahmad
    DENTISTRY JOURNAL, 2019, 7 (03)
  • [40] Volumetric analysis of the mandibular condyle using cone beam computed tomography
    Bayram, Mehmet
    Kayipmaz, Saadettin
    Sezgin, Omer Said
    Kucuk, Murat
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (08) : 1812 - 1816