The reliability of computed tomography (CT) values and dimensional measurements of the oropharyngeal region using cone beam CT: comparison with multidetector CT

被引:89
|
作者
Yamashina, A. [1 ]
Tanimoto, K. [1 ]
Sutthiprapaporn, P. [1 ,2 ]
Hayakawa, Y. [3 ]
机构
[1] Hiroshima Univ, Grad Sch Biomed Sci, Dept Oral & Maxillofacial Surg, Hiroshima 730, Japan
[2] Khon Kaen Univ, Fac Dent, Dept Oral Diag, Khon Kaen, Thailand
[3] Kitami Inst Technol, Fac Engn, Dept Comp Sci, Kitami, Hokkaido, Japan
关键词
computed tomography; cone beam; computed tomography value; oropharynx;
D O I
10.1259/dmfr/45926904
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To evaluate the reliability of cone beam CT (CBCT) values and dimensional measurements of oropharyngeal air spaces as compared with those of multidetector row CT (MDCT). Methods: A soft tissue equivalent phantom with different sized holes was used. The phantom was scanned using CBCT and MDCT. In addition, a volunteer was examined using both methods for clinical comparison. The CT data were retrieved to a personal computer and treated using image processing software for three-dimensional rendering and dimensional measurements. The CT values of air, water and soft tissues were measured experimentally and the CT values of air, fat and muscle were measured in a clinical case. The diameter of each hole drilled in the phantom was measured on CBCT and MDCT images using the software tool and digimatic callipers. Results: The CBCT values were quite different from the Hounsfield units obtained with a typical MDCT system. The standard deviations were almost ten times larger with CBCT. In vivo assessment showed that the CBCT values for fat had a wide range that partially overlapped the values for muscle. The measurement of distances greater than 4 mm was consistent for all methods. The difference for holes was less than 0.2 mm. Conclusions: The phantom study showed that CBCT provides limited quantitative CT values for each pixel on sliced images for differentiating air, water and soft tissues. However, the measurement of air spaces with CBCT was quite accurate.
引用
收藏
页码:245 / 251
页数:7
相关论文
共 50 条
  • [41] Organ doses can be estimated from the computed tomography (CT) dose index for cone-beam CT on radiotherapy equipment
    Martin, Colin J.
    Abuhaimed, Abdullah
    Sankaralingam, Marimuthu
    Metwaly, Mohamed
    Gentle, David J.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2016, 36 (02) : 215 - 229
  • [42] Adaptive CaRdiac cOne BEAm computed Tomography (ACROBEAT): Developing the next generation of cardiac cone beam CT imaging
    Reynolds, Tess
    Dillon, Owen
    Prinable, Joseph
    Whelan, Brendan
    Keall, Paul J.
    O'Brien, Ricky T.
    MEDICAL PHYSICS, 2021, 48 (05) : 2543 - 2552
  • [43] Attenuation correction in SPECT/CT using a cone beam CT and varying the CT dose (mA) and the CT reconstruction
    St James, Sara
    Badawi, Ramsey
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [44] Comparison of the Radiation Dose from Cone Beam Computed Tomography and Multidetector Computed Tomography in Examinations of the Hand
    Neubauer, J.
    Neubauer, C.
    Gerstmair, A.
    Krauss, T.
    Reising, K.
    Zajonc, H.
    Kotter, E.
    Langer, M.
    Fiebich, M.
    Voigt, J.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2016, 188 (05): : 488 - 493
  • [46] DAP Measurements in Dental/Maxillofacial Cone Beam CT
    Gingold, E.
    Stratis, A.
    Mihailidis, D.
    MEDICAL PHYSICS, 2020, 47 (06) : E523 - E523
  • [47] Measurements for quality assurance in the cone-beam CT
    Walter, C.
    Wertz, H.
    Steil, V.
    Lohr, F.
    Wenz, F.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2006, 182 : 95 - 96
  • [48] Multidetector computed tomography (MDCT): simple CT protocol for trauma patient
    Eichler, Katrin
    Marzi, Ingo
    Wyen, Hendrik
    Zangos, Stephan
    Mack, Martin G.
    Vogl, Thomas J.
    CLINICAL IMAGING, 2015, 39 (01) : 110 - 115
  • [49] Reliability of three-dimensional measurements of the upper airway on cone beam computed tomography images
    Chen, Hui
    Aarab, Ghizlane
    Parsa, Azin
    de Lange, Jan
    van der Stelt, Paul F.
    Lobbezoo, Frank
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2016, 122 (01): : 104 - 110
  • [50] Diagnostic value of cone beam computed tomography for root canal morphology assessment – a micro-CT based comparison
    Mariana Pires
    Jorge N.R. Martins
    Mário Rito Pereira
    Isabel Vasconcelos
    Rui Pereira da Costa
    Isabel Duarte
    António Ginjeira
    Clinical Oral Investigations, 28