X-ray Sources for Adaptive Radiography and Computed Tomography

被引:6
|
作者
Kutsaev, S., V [1 ]
Agustsson, R. [1 ]
Arodzero, A. [1 ]
Boucher, S. [1 ]
Burstein, P. [1 ]
Smirnov, A. Yu [1 ]
机构
[1] RadiaBeam Technol, 1717 Stewart St, Santa Monica, CA 90404 USA
关键词
X-ray radiography; Computed tomography; Multi-energy material discrimination; Electron accelerator; Linac; Homeland security; DESIGN;
D O I
10.1063/1.5127706
中图分类号
O59 [应用物理学];
学科分类号
摘要
X-ray multi-energy adaptive security radiography and computed tomography inspection techniques have superior performance compared to conventional dual-energy methods where two image slices are acquired by alternating energies. This new technique allows improving the quality of radiographic and CT images, expanding the range of areal densities of the interrogated objects over which effective discrimination of materials by atomic number is possible, eliminating artifacts in the image of boundaries of different densities, and reducing the time of inspection and the required dose. For this new inspection technology, RadiaBeam Technologies is developing several new types of x-ray sources that are based on linear electron accelerators. To provide an adaptive mode of operation of inspection systems, such accelerators use fast feedback from the detector array. Depending on the application, the range of the electron energy can vary from 180 keV up to 9 MeV. In this paper, we discuss the requirements for such linear accelerators, some details about their designs, and present the results of high-power and beam testing of the S- and X-band accelerators.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Ptychographic X-ray computed tomography at the nanoscale
    Dierolf, Martin
    Menzel, Andreas
    Thibault, Pierre
    Schneider, Philipp
    Kewish, Cameron M.
    Wepf, Roger
    Bunk, Oliver
    Pfeiffer, Franz
    NATURE, 2010, 467 (7314) : 436 - U82
  • [42] X-Ray Luminescence Computed Tomography Via Selective X-Ray Excitation
    Pratx, G.
    Carpenter, C.
    Sun, C.
    Xing, L.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [43] Signal statistics of x-ray computed tomography
    Whiting, BR
    MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 53 - 60
  • [44] Development of dimensional X-ray computed tomography
    National Metrology Institute of Japan , National Institute of Advanced Industrial Science and Technology , 1-1-1 Umezono, Tsukuba
    Ibaraki
    305-8563, Japan
    Int. J. Autom. Technol., 5 (567-571):
  • [45] NOISE LIMITATIONS IN X-RAY COMPUTED TOMOGRAPHY
    TRETIAK, OJ
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1978, 2 (04) : 477 - 480
  • [46] Ptychographic X-ray computed tomography at the nanoscale
    Martin Dierolf
    Andreas Menzel
    Pierre Thibault
    Philipp Schneider
    Cameron M. Kewish
    Roger Wepf
    Oliver Bunk
    Franz Pfeiffer
    Nature, 2010, 467 : 436 - 439
  • [47] APPLIED X-RAY COMPUTED-TOMOGRAPHY
    BUYNAK, CF
    BOSSI, RH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 99 (1-4): : 772 - 774
  • [48] X-ray computed tomography of polymer composites
    Garcea, S. C.
    Wang, Y.
    Withers, P. J.
    COMPOSITES SCIENCE AND TECHNOLOGY, 2018, 156 : 305 - 319
  • [49] X-ray micro computed-tomography
    Baird, Emily
    Taylor, Gavin
    CURRENT BIOLOGY, 2017, 27 (08) : R289 - R291
  • [50] X-Ray Computed Tomography Through Scatter
    Geva, Adam
    Schechner, Yoav Y.
    Chernyak, Yonatan
    Gupta, Rajiv
    COMPUTER VISION - ECCV 2018, PT XIV, 2018, 11218 : 37 - 54