X-ray Sources for Adaptive Radiography and Computed Tomography

被引:6
|
作者
Kutsaev, S., V [1 ]
Agustsson, R. [1 ]
Arodzero, A. [1 ]
Boucher, S. [1 ]
Burstein, P. [1 ]
Smirnov, A. Yu [1 ]
机构
[1] RadiaBeam Technol, 1717 Stewart St, Santa Monica, CA 90404 USA
关键词
X-ray radiography; Computed tomography; Multi-energy material discrimination; Electron accelerator; Linac; Homeland security; DESIGN;
D O I
10.1063/1.5127706
中图分类号
O59 [应用物理学];
学科分类号
摘要
X-ray multi-energy adaptive security radiography and computed tomography inspection techniques have superior performance compared to conventional dual-energy methods where two image slices are acquired by alternating energies. This new technique allows improving the quality of radiographic and CT images, expanding the range of areal densities of the interrogated objects over which effective discrimination of materials by atomic number is possible, eliminating artifacts in the image of boundaries of different densities, and reducing the time of inspection and the required dose. For this new inspection technology, RadiaBeam Technologies is developing several new types of x-ray sources that are based on linear electron accelerators. To provide an adaptive mode of operation of inspection systems, such accelerators use fast feedback from the detector array. Depending on the application, the range of the electron energy can vary from 180 keV up to 9 MeV. In this paper, we discuss the requirements for such linear accelerators, some details about their designs, and present the results of high-power and beam testing of the S- and X-band accelerators.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] X-ray and neutron radiography and tomography in research and industry
    Presnyakov, A. Yu
    Mikerov, V., I
    Gerasimchuk, O. A.
    Yurkov, D., I
    PHYSICS-USPEKHI, 2024, 67 (06) : 577 - 587
  • [32] UGCT: New x-ray radiography and tomography facility
    Masschaele, B. C.
    Cnudde, V.
    Dierick, M.
    Jacobs, P.
    Van Hoorebeke, L.
    Vlassenbroeck, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 266 - 269
  • [33] X-ray luminescence computed tomography using a focused x-ray beam
    Zhang, Wei
    Lun, Michael C.
    Nguyen, Alex Anh-Tu
    Li, Changqing
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (11)
  • [34] STATISTICAL ASPECTS OF COMPUTED X-RAY TOMOGRAPHY
    CHESLER, DA
    PELC, NJ
    RIEDERER, SJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (01): : 130 - 131
  • [35] X-ray computed tomography of ultralightweight metals
    Winter, JM
    Green, RE
    Waters, AM
    Green, WH
    RESEARCH IN NONDESTRUCTIVE EVALUATION, 1999, 11 (04) : 199 - 211
  • [36] X-ray computed tomography for medical imaging
    Hiriyannaiah, HP
    IEEE SIGNAL PROCESSING MAGAZINE, 1997, 14 (02) : 42 - 59
  • [37] Contemporary developments in computed X-ray tomography
    Seibert, JA
    RADIOLOGY, 1998, 209P : 207 - 208
  • [38] Microscopic x-ray luminescence computed tomography
    Zhang, Wei
    Zhu, Dianwen
    Zhang, Kun
    Li, Changqing
    MULTIMODAL BIOMEDICAL IMAGING X, 2015, 9316
  • [39] X-ray computed tomography in life sciences
    Shelley D. Rawson
    Jekaterina Maksimcuka
    Philip J. Withers
    Sarah H. Cartmell
    BMC Biology, 18
  • [40] Image Analysis in X-ray Computed Tomography
    Seletchi, Emilia Dana
    Sutac, Victor
    PROCEEDINGS OF THE 1ST INTERNATIONAL CONFERENCE ON VIRTUAL LEARNING: VIRTUAL LEARNING - VIRTUAL REALITY: MODELS & METHODOLOGIES, TECHNOLOGIES, SOFTWARE SOLUTIONS, 2006, : 187 - +