X-ray Sources for Adaptive Radiography and Computed Tomography

被引:6
|
作者
Kutsaev, S., V [1 ]
Agustsson, R. [1 ]
Arodzero, A. [1 ]
Boucher, S. [1 ]
Burstein, P. [1 ]
Smirnov, A. Yu [1 ]
机构
[1] RadiaBeam Technol, 1717 Stewart St, Santa Monica, CA 90404 USA
关键词
X-ray radiography; Computed tomography; Multi-energy material discrimination; Electron accelerator; Linac; Homeland security; DESIGN;
D O I
10.1063/1.5127706
中图分类号
O59 [应用物理学];
学科分类号
摘要
X-ray multi-energy adaptive security radiography and computed tomography inspection techniques have superior performance compared to conventional dual-energy methods where two image slices are acquired by alternating energies. This new technique allows improving the quality of radiographic and CT images, expanding the range of areal densities of the interrogated objects over which effective discrimination of materials by atomic number is possible, eliminating artifacts in the image of boundaries of different densities, and reducing the time of inspection and the required dose. For this new inspection technology, RadiaBeam Technologies is developing several new types of x-ray sources that are based on linear electron accelerators. To provide an adaptive mode of operation of inspection systems, such accelerators use fast feedback from the detector array. Depending on the application, the range of the electron energy can vary from 180 keV up to 9 MeV. In this paper, we discuss the requirements for such linear accelerators, some details about their designs, and present the results of high-power and beam testing of the S- and X-band accelerators.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Dynamic X-ray computed tomography
    Bonnet, S
    Koenig, A
    Roux, S
    Hugonnard, P
    Guillemaud, R
    Grangeat, P
    PROCEEDINGS OF THE IEEE, 2003, 91 (10) : 1574 - 1587
  • [22] Industrial computed X-ray tomography
    Luthi, T
    Flisch, A
    Wyss, P
    INSIGHT, 1998, 40 (03) : 196 - 197
  • [23] Design for X-Ray Computed Tomography
    Moroni, Giovanni
    Petro, Stefano
    29TH CIRP DESIGN CONFERENCE 2019, 2019, 84 : 173 - 178
  • [24] Dose in x-ray computed tomography
    Kalender, Willi A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (03): : R129 - R150
  • [25] X-ray computed tomography of the heart
    Wijesekera, Nevin T.
    Duncan, Mark K.
    Padley, Simon P. G.
    BRITISH MEDICAL BULLETIN, 2010, 93 (01) : 49 - 67
  • [26] X-ray computed tomography using projection X-ray microscope
    Yoshimura, F
    Miyata, C
    Kuzuryu, C
    Hori, A
    Obi, T
    Ohyama, N
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 166 - 171
  • [27] Effects of microstructure on water imbibition in sandstones using X-ray computed tomography and neutron radiography
    Zhao, Yixin
    Xue, Shanbin
    Han, Songbai
    Chen, Zhongwei
    Liu, Shimin
    Elsworth, Derek
    He, Linfeng
    Cai, Jianchao
    Liu, Yuntao
    Chen, Dongfeng
    JOURNAL OF GEOPHYSICAL RESEARCH-SOLID EARTH, 2017, 122 (07) : 4963 - 4981
  • [28] ACTM: Adaptive Computed Tomography with Modulated-Energy X-ray Pulses
    Arodzero, Anatoli
    Boucher, Salime
    Burstein, Paul
    Frenkel, Michael
    Katsevich, Alexander
    Kutsaev, Sergey V.
    Lanza, Richard C.
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [29] Statistically Adaptive Filtering for Low Signal Correction in X-ray Computed Tomography
    Rahman, Obaidullah
    Sauer, Ken D.
    Bouman, Charles A.
    Melnyk, Roman
    Nett, Brian E.
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [30] Quantitative cone beam X-ray luminescence tomography/X-ray computed tomography imaging
    Chen, Dongmei
    Zhu, Shouping
    Chen, Xueli
    Chao, Tiantian
    Cao, Xu
    Zhao, Fengjun
    Huang, Liyu
    Liang, Jimin
    APPLIED PHYSICS LETTERS, 2014, 105 (19)