Utilization of virtual non-contrast images derived from dual-energy CT in evaluation of biliary stone disease: Virtual non-contrast image can replace true non-contrast image regarding biliary stone detection

被引:14
|
作者
Bae, Jae Seok [1 ,2 ]
Lee, Dong Ho [1 ,2 ]
Joo, Ijin [1 ,2 ]
Jeon, Sun Kyung [1 ]
Han, Joon Koo [1 ,2 ,3 ]
机构
[1] Seoul Natl Univ Hosp, Dept Radiol, 101 Daehak Ro, Seoul 03080, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Radiol, 103 Daehak Ro, Seoul 03080, South Korea
[3] Seoul Natl Univ, Med Res Ctr, Inst Radiat Med, 103 Daehak Ro, Seoul 03080, South Korea
关键词
Dual-energy computed tomography; Contrast media; Cholelithiasis; Choledocholithiasis; BILE-DUCT STONES; SPECTRAL COMPUTED-TOMOGRAPHY; NONENHANCED IMAGES; HELICAL CT; GALLSTONES; ACCURACY; CHOLEDOCHOLITHIASIS; DIAGNOSIS; ERCP;
D O I
10.1016/j.ejrad.2019.04.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To compare the virtual non-contrast (VNC) images acquired through dual-energy computed tomography (DECT) with the true non-contrast (TNC) images in the detection of biliary stones and to calculate dose reduction by replacing TNC images with VNC images. Methods: Between March 2017 and April 2018, we retrospectively enrolled 75 patients with suspicious biliary disease who underwent dual-source DECT and surgery and/or endoscopic intervention within 2 months from the CT. Biliary stones were present in 45 patients. The sensitivity and specificity for detecting gallstone and common bile duct (CBD) stone were compared between the VNC and TNC using McNemar test. In addition, the possible reduction in radiation dose was calculated. Results: In our study, 37 patients had gallstones, 2 had CBD stones, and 6 had both gallstone and CBD stones. For detection of gallstones, the sensitivity and specificity were 90.7% (39/43) and 87.5% (28/32), respectively, for the TNC images, and 88.4% (38/43) and 90.6% (29/32), respectively, for the VNC images. With respect to CBD stones, the sensitivity and specificity were 87.5% (7/8) and 98.5% (66/67), respectively, for the TNC images, and 75.0% (6/8) and 100% (67/67), respectively, for the VNC images. There was no significant difference in the sensitivity and specificity between each image set (P > 0.05). The radiation dose reduction of 22.4 +/- 1.3% is expected by omitting TNC images. Conclusions: The VNC images derived from DECT were comparable to the TNC images for the detection of biliary stones and may replace the TNC images to reduce radiation dose.
引用
收藏
页码:34 / 40
页数:7
相关论文
共 50 条
  • [41] Virtual non-contrast detector-based spectral CT predictably overestimates tissue density for the characterisation of adrenal lesions compared to true non-contrast CT
    Shern Liang, Ee
    Wastney, Timothy
    Dobeli, Karen
    Hacking, Craig
    ABDOMINAL RADIOLOGY, 2022, 47 (07) : 2462 - 2467
  • [42] Dedicated virtual non-contrast images adapted for liver tissue in clinical photon counting CT improve virtual non-contrast imaging in various organs beyond the liver
    Schoenbeck, Denise
    Haag, Nina Pauline
    Michael, Arwed Elias
    Woeltjen, Matthias Michael
    Boriesosdick, Jan
    Saeed, Saher
    Borggrefe, Jan
    Kroeger, Jan Robert
    Niehoff, Julius Henning
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 167
  • [43] Virtual Non-Contrast CT Using Dual-Energy Spectral CT: Feasibility of Coronary Artery Calcium Scoring
    Song, Inyoung
    Yi, Jeong Geun
    Park, Jeong Hee
    Kim, Sung Mok
    Lee, Kyung Soo
    Chung, Myung Jin
    KOREAN JOURNAL OF RADIOLOGY, 2016, 17 (03) : 321 - 329
  • [44] Dual-Energy Computed Tomography in Stroke Imaging: Value of Virtual Non-Contrast Images for Detection of the Hyperdense Artery Sign
    Winklhofer, S.
    De Martini, V.
    Nern, Ch
    Blume, I.
    Wegener, S.
    Pangalu, A.
    Valavanis, A.
    Alkadhi, H.
    Guggenberger, R.
    SWISS MEDICAL WEEKLY, 2016, 146 : 172S - 173S
  • [45] Virtual non-contrast dual-energy CT compared to single-energy CT of the urinary tract: a prospective study
    Lundin, Margareta
    Liden, Mats
    Magnuson, Anders
    Mohammed, Ahmed Abdulilah
    Geijer, Hakan
    Andersson, Torbjorn
    Persson, Anders
    ACTA RADIOLOGICA, 2012, 53 (06) : 689 - 694
  • [46] Virtual monoenergetic dual-energy CT reconstructions at 80 keV are optimal non-contrast CT technique for early stroke detection
    Dodig, Doris
    Kastelan, Zrinka Matana
    Bartolovic, Nina
    Jurkovic, Slaven
    Miletic, Damir
    Rumboldt, Zoran
    NEURORADIOLOGY JOURNAL, 2022, 35 (03): : 337 - 345
  • [47] Combining non-contrast and dual-energy CT improves diagnosis of early gout
    Lee, Seul Ki
    Jung, Joon-Yong
    Jee, Won-Hee
    Lee, Jennifer Jooha
    Park, Sung-Hwan
    EUROPEAN RADIOLOGY, 2019, 29 (03) : 1267 - 1275
  • [48] Comparison of true non- contrast and virtual non-contrast images in the characterization of renal lesions using detector- based spectral CT
    Verstraeten, Sabine
    Ansems, Janneke
    Van Ommen, Wenzel
    Van Der Linden, Diana
    Looijmans, Frank
    Tesselaar, Erik
    BRITISH JOURNAL OF RADIOLOGY, 2023, 96 (1149):
  • [49] Comparison of True and Virtual Non-Contrast Images of Liver Obtained with Single-Source Twin Beam and Dual-Source Dual-Energy CT
    Lee, Jeong Sub
    Choi, Guk Myung
    Kim, Bong Soo
    Ko, Su Yeon
    Lee, Kyung Ryeol
    Kim, Jeong Jae
    Kim, Doo Ri
    JOURNAL OF THE KOREAN SOCIETY OF RADIOLOGY, 2023, 84 (01): : 170 - 184
  • [50] Combining non-contrast and dual-energy CT improves diagnosis of early gout
    Seul Ki Lee
    Joon-Yong Jung
    Won-Hee Jee
    Jennifer Jooha Lee
    Sung-Hwan Park