Utilization of virtual non-contrast images derived from dual-energy CT in evaluation of biliary stone disease: Virtual non-contrast image can replace true non-contrast image regarding biliary stone detection

被引:14
|
作者
Bae, Jae Seok [1 ,2 ]
Lee, Dong Ho [1 ,2 ]
Joo, Ijin [1 ,2 ]
Jeon, Sun Kyung [1 ]
Han, Joon Koo [1 ,2 ,3 ]
机构
[1] Seoul Natl Univ Hosp, Dept Radiol, 101 Daehak Ro, Seoul 03080, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Radiol, 103 Daehak Ro, Seoul 03080, South Korea
[3] Seoul Natl Univ, Med Res Ctr, Inst Radiat Med, 103 Daehak Ro, Seoul 03080, South Korea
关键词
Dual-energy computed tomography; Contrast media; Cholelithiasis; Choledocholithiasis; BILE-DUCT STONES; SPECTRAL COMPUTED-TOMOGRAPHY; NONENHANCED IMAGES; HELICAL CT; GALLSTONES; ACCURACY; CHOLEDOCHOLITHIASIS; DIAGNOSIS; ERCP;
D O I
10.1016/j.ejrad.2019.04.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To compare the virtual non-contrast (VNC) images acquired through dual-energy computed tomography (DECT) with the true non-contrast (TNC) images in the detection of biliary stones and to calculate dose reduction by replacing TNC images with VNC images. Methods: Between March 2017 and April 2018, we retrospectively enrolled 75 patients with suspicious biliary disease who underwent dual-source DECT and surgery and/or endoscopic intervention within 2 months from the CT. Biliary stones were present in 45 patients. The sensitivity and specificity for detecting gallstone and common bile duct (CBD) stone were compared between the VNC and TNC using McNemar test. In addition, the possible reduction in radiation dose was calculated. Results: In our study, 37 patients had gallstones, 2 had CBD stones, and 6 had both gallstone and CBD stones. For detection of gallstones, the sensitivity and specificity were 90.7% (39/43) and 87.5% (28/32), respectively, for the TNC images, and 88.4% (38/43) and 90.6% (29/32), respectively, for the VNC images. With respect to CBD stones, the sensitivity and specificity were 87.5% (7/8) and 98.5% (66/67), respectively, for the TNC images, and 75.0% (6/8) and 100% (67/67), respectively, for the VNC images. There was no significant difference in the sensitivity and specificity between each image set (P > 0.05). The radiation dose reduction of 22.4 +/- 1.3% is expected by omitting TNC images. Conclusions: The VNC images derived from DECT were comparable to the TNC images for the detection of biliary stones and may replace the TNC images to reduce radiation dose.
引用
收藏
页码:34 / 40
页数:7
相关论文
共 50 条
  • [31] Coronary calcium scoring on virtual non-contrast and virtual non-iodine reconstructions compared to true non-contrast images using photon-counting computed tomography
    Sharma, Simran P.
    van der Bie, Judith
    van Straten, Marcel
    Hirsch, Alexander
    Bos, Daniel
    Dijkshoorn, Marcel L.
    Booij, Ronald
    Budde, Ricardo P. J.
    EUROPEAN RADIOLOGY, 2024, 34 (06) : 3699 - 3707
  • [32] Calcium scoring using virtual non-contrast images from a dual-layer spectral detector CT: comparison to true non-contrast data and evaluation of proportionality factor in a large patient collective
    Felix G. Gassert
    Claudio E. Schacky
    Christina Müller-Leisse
    Florian T. Gassert
    Gregor Pahn
    Karl-Ludwig Laugwitz
    Marcus R. Makowski
    Jonathan Nadjiri
    European Radiology, 2021, 31 : 6193 - 6199
  • [33] Calcium scoring using virtual non-contrast images from a dual-layer spectral detector CT: comparison to true non-contrast data and evaluation of proportionality factor in a large patient collective
    Gassert, Felix G.
    Schacky, Claudio E.
    Mueller-Leisse, Christina
    Gassert, Florian T.
    Pahn, Gregor
    Laugwitz, Karl-Ludwig
    Makowski, Marcus R.
    Nadjiri, Jonathan
    EUROPEAN RADIOLOGY, 2021, 31 (08) : 6193 - 6199
  • [34] Virtual versus true non-contrast images of the brain from spectral detector CT: comparison of attenuation values and image quality
    Kessner, Rivka
    Sommer, Jennifer
    Hokamp, Nils Grosse
    Laukamp, Kai R.
    Nayate, Ameya
    ACTA RADIOLOGICA, 2023, 64 (02) : 776 - 783
  • [35] Evaluation of Deformable Image Registration Accuracy for Liver Patients Using Contrast and Non-Contrast CT Images
    Allen, C.
    Yeo, A.
    Hardcastle, N.
    Franich, R.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [36] Single-energy non-contrast hepatic steatosis criteria applied to virtual non-contrast images: is it still highly specific and positively predictive?
    Haji-Momenian, S.
    Parkinson, W.
    Khati, N.
    Brindle, K.
    Earls, J.
    Zeman, R. K.
    CLINICAL RADIOLOGY, 2018, 73 (06) : 594.e7 - 594.e15
  • [37] Virtual non-contrast detector-based spectral CT predictably overestimates tissue density for the characterisation of adrenal lesions compared to true non-contrast CT
    Ee Shern Liang
    Timothy Wastney
    Karen Dobeli
    Craig Hacking
    Abdominal Radiology, 2022, 47 : 2462 - 2467
  • [38] Detection of moderate hepatic steatosis on contrast-enhanced dual-source dual-energy CT: Role and accuracy of virtual non-contrast CT
    Catania, Roberta
    Jia, Leo
    Haghshomar, Maryam
    Miller, Frank H.
    Borhani, Amir A.
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 172
  • [39] Multiphase photon counting detector CT data sets - Which combination of contrast phase and virtual non-contrast algorithm is best suited to replace true non-contrast series in the assessment of active bleeding?
    Risch, Franka
    Bette, Stefanie
    Sinzinger, Andrea
    Rippel, Katharina
    Scheurig-Muenkler, Christian
    Kroencke, Thomas
    Decker, Josua A.
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 168
  • [40] Virtual Non-Contrast versus True Non-Contrast Computed Tomography: Initial Experiences with a Photon Counting Scanner Approved for Clinical Use
    Niehoff, Julius Henning
    Woeltjen, Matthias Michael
    Laukamp, Kai Roman
    Borggrefe, Jan
    Kroeger, Jan Robert
    DIAGNOSTICS, 2021, 11 (12)