Detection of moderate hepatic steatosis on contrast-enhanced dual-source dual-energy CT: Role and accuracy of virtual non-contrast CT

被引:2
|
作者
Catania, Roberta [1 ]
Jia, Leo [1 ]
Haghshomar, Maryam [1 ]
Miller, Frank H. [1 ]
Borhani, Amir A. [1 ]
机构
[1] Northwestern Univ, Dept Radiol, Feinberg Sch Med, 676 N St Clair St, Arkes Family Pavil, Suite 800, Chicago, IL 60611 USA
关键词
Dual-energy CT; Spectral CT; Virtual non-contrast; Virtual unenhanced; Fatty liver; Steatosis; FATTY LIVER-DISEASE; TOMOGRAPHY PHYSICAL PRINCIPLES; COMPUTED-TOMOGRAPHY; QUANTIFICATION; INFILTRATION; ASSOCIATION; DIAGNOSIS; USAGE; MRI;
D O I
10.1016/j.ejrad.2024.111328
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate diagnostic accuracy of virtual non contrast (VNC) images, based on dual-source dualenergy CT (dsDECT), for detection of at least moderate steatosis and to define a threshold value to make this diagnosis on VNC. Methods: This single-institution retrospective study included patients who had multi-phasic protocol dsDECT. Regions of interests were placed in different segments of the liver and spleen on true non-contrast (TNC), VNC, and portal-venous phase (PVP) images. At least moderate steatosis was defined as liver attenuation (LHU) < 40 HU on TNC. Diagnostic performance of VNC to detect steatosis was determined and the new threshold was tested in a validation cohort. Results: 236 patients were included in training cohort. Mean liver attenuation values were 51.3 +/- 10.8 HU and 58.1 +/- 11.5 HU for TNC and VNC (p < 0.001), with a mean difference (VNC - TNC) of 6.8 +/- 6.9 HU. Correlation between TNC and VNC was strong (r = 0.81, p < 0.001). The AUCs of LHU on VNC for detection of hepatic steatosis were 0.92 (95 % Cl: 0.86-0.98), 0.92 (95 % Cl: 0.87-0.97), 0.92 (95 % Cl: 0.86-0.99), 0.91 (95 % Cl: 0.84-0.97), and 0.87 (95 % Cl: 0.80-0.95) for entire liver, left lateral, left medial, right anterior, and right posterior segments, respectively. VNC had sensitivity/specificity of 100 % /42 % when using a threshold of 40 HU; they were 69 % and 95 %, respectively, when using optimized threshold of 46 HU. This threshold showed similar performance in validation cohort (n = 80). Conclusions: Hepatic attenuation on VNC has promising performance for detection of at least moderate steatosis. Proposed threshold of 46 HU provides high specificity and moderate sensitivity to detect steatosis.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Detection of fatty liver using virtual non-contrast dual-energy CT
    Zhang, Pengcheng Peter
    Choi, Hailey H.
    Ohliger, Michael A.
    ABDOMINAL RADIOLOGY, 2022, 47 (06) : 2046 - 2056
  • [2] Detection of fatty liver using virtual non-contrast dual-energy CT
    Pengcheng Peter Zhang
    Hailey H. Choi
    Michael A. Ohliger
    Abdominal Radiology, 2022, 47 : 2046 - 2056
  • [3] Quantitative Accuracy of Virtual Non-Contrast Imaging in Various Dual-Energy CT Scanners
    Ahmad, M.
    Jacobsen, M.
    Cody, D.
    Surabhi, V.
    MEDICAL PHYSICS, 2018, 45 (06) : E154 - E154
  • [4] Dual-Energy CT in Acute Stroke: Could Non-Contrast CT Be Replaced by Virtual Non-Contrast CT? A Feasibility Study
    Herpe, Guillaume
    Platon, Alexandra
    Poletti, Pierre-Alexandre
    Lovblad, Karl O.
    Machi, Paolo
    Becker, Minerva
    Muster, Michel
    Perneger, Thomas
    Guillevin, Remy
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (13)
  • [5] Task-Based Optimal Dose Partitioning in Dual-Source Dual-Energy CT for Virtual Non-Contrast and Iodine Imaging
    Long, L.
    McCollough, C.
    Yu, L.
    MEDICAL PHYSICS, 2018, 45 (06) : E675 - E675
  • [6] Comparison of True and Virtual Non-Contrast Images of Liver Obtained with Single-Source Twin Beam and Dual-Source Dual-Energy CT
    Lee, Jeong Sub
    Choi, Guk Myung
    Kim, Bong Soo
    Ko, Su Yeon
    Lee, Kyung Ryeol
    Kim, Jeong Jae
    Kim, Doo Ri
    JOURNAL OF THE KOREAN SOCIETY OF RADIOLOGY, 2023, 84 (01): : 170 - 184
  • [7] Liver virtual non-enhanced CT with dual-source, dual-energy CT: a preliminary study
    Long-Jiang Zhang
    Jin Peng
    Sheng-Yong Wu
    Z. Jane Wang
    Xin-Sheng Wu
    Chang-Sheng Zhou
    Xue-Man Ji
    Guang-Ming Lu
    European Radiology, 2010, 20 : 2257 - 2264
  • [8] Virtual Non-Contrast Dual-Energy CT for Proton Therapy Dose Calculation
    Lalonde, A.
    Xie, Y.
    Burgdorf, B.
    O'Reilly, S.
    Ingram, W.
    Yin, L.
    Zou, J.
    Dong, L.
    Bouchard, H.
    Teo, B.
    MEDICAL PHYSICS, 2019, 46 (06) : E127 - E128
  • [9] Liver virtual non-enhanced CT with dual-source, dual-energy CT: a preliminary study
    Zhang, Long-Jiang
    Peng, Jin
    Wu, Sheng-Yong
    Wang, Z. Jane
    Wu, Xin-Sheng
    Zhou, Chang-Sheng
    Ji, Xue-Man
    Lu, Guang-Ming
    EUROPEAN RADIOLOGY, 2010, 20 (09) : 2257 - 2264
  • [10] Accuracy of Dual-Energy CT Virtual Non-Contrast/unenhanced and Material Density Images: A Phantom Study
    Li, B.
    Pomerleau, M.
    Gupta, A.
    Soto, J.
    Anderson, S.
    MEDICAL PHYSICS, 2020, 47 (06) : E511 - E512