Comparison of True and Virtual Non-Contrast Images of Liver Obtained with Single-Source Twin Beam and Dual-Source Dual-Energy CT

被引:0
|
作者
Lee, Jeong Sub [1 ]
Choi, Guk Myung [1 ]
Kim, Bong Soo [1 ]
Ko, Su Yeon [1 ]
Lee, Kyung Ryeol [1 ]
Kim, Jeong Jae [1 ]
Kim, Doo Ri [1 ]
机构
[1] Jeju Natl Univ, Coll Med, Jeju Natl Univ Hosp, Dept Radiol, 15 Aran 13 Gil, Jeju 63241, South Korea
来源
关键词
Radiography; Dual-Energy Scanned Projection; Tomography; X-Ray Computed; Feasibility Studies; COMPUTED-TOMOGRAPHY; ATTENUATION VALUES; NONCONTRAST IMAGES; UNENHANCED IMAGES; ENHANCED CT; ACCURACY; QUALITY;
D O I
10.3348/jksr.2021.0193
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To assess the magnitude of differences between attenuation values of the true non -contrast image (TNC) and virtual non -contrast image (VNC) derived from twin -beam dual -energy CT (tbDECT) and dual-source DECT (dsDECT).<br /> Materials and Methods This retrospective study included 62 patients who underwent liver dynamic DECT with tbDECT ( n = 32) or dsDECT ( n = 30). Arterial VNC (AVNC), portal VNC (PVNC), and delayed VNC (DVNC) were reconstructed using multiphasic DECT. Attenuation values of multiple intra-abdominal organs ( n = 11) on TNCs were subsequently compared to those on multiphasic VNCs. Further, we investigated the percentage of cases with an absolute difference between TNC and VNC of <= 10 Hounsfield units (HU).<br /> Results For the mean attenuation values of TNC and VNC, 33 items for each DECT were compared according to the multiphasic VNCs and organs. More than half of the comparison items for each DECT showed significant differences (tbDECT 17/33; dsDECT 19/33; Bonferroni correction p < 0.0167). The percentage of cases with an absolute difference <= 10 HU was 56.7%, 69.2%, and 78.6% in AVNC, PVNC, and DVNC in tbDECT, respectively, and 70.5%, 78%, and 78% in dsDECT, respectively.<br /> Conclusion VNCs derived from the two DECTs were insufficient to replace TNCs because of the considerable difference in attenuation values.
引用
收藏
页码:170 / 184
页数:15
相关论文
共 50 条
  • [1] Dual-energy CT of the pancreas: comparison between virtual non-contrast images and true non-contrast images in the detection of pancreatic lesion
    Hongwei Liang
    Silin Du
    Gaowu Yan
    Yang Zhou
    Tianyu Yang
    Zhiwei Zhang
    Chenyi Luo
    Hongfan Liao
    Yongmei Li
    Abdominal Radiology, 2023, 48 : 2596 - 2603
  • [2] Dual-energy CT of the pancreas: comparison between virtual non-contrast images and true non-contrast images in the detection of pancreatic lesion
    Liang, Hongwei
    Du, Silin
    Yan, Gaowu
    Zhou, Yang
    Yang, Tianyu
    Zhang, Zhiwei
    Luo, Chenyi
    Liao, Hongfan
    Li, Yongmei
    ABDOMINAL RADIOLOGY, 2023, 48 (08) : 2596 - 2603
  • [3] Detection of moderate hepatic steatosis on contrast-enhanced dual-source dual-energy CT: Role and accuracy of virtual non-contrast CT
    Catania, Roberta
    Jia, Leo
    Haghshomar, Maryam
    Miller, Frank H.
    Borhani, Amir A.
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 172
  • [4] Abdominal Attenuation Values on Virtual and True Unenhanced Images Obtained With Third-Generation Dual-Source Dual-Energy CT
    Durieux, Pierre
    Gevenois, Pierre Alain
    Van Muylem, Alain
    Howarth, Nigel
    Keyzer, Caroline
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (05) : 1042 - 1058
  • [5] Virtual non-contrast images from dual-energy CT angiography of the abdominal aorta and femoral arteries: comparison with true non-contrast CT images
    Lee, Min Hee
    Park, Hee Jin
    Kim, Ji Na
    Kim, Myung Sub
    Hong, Seok Woo
    Park, Jai Hyung
    Kang, Chang Ho
    BRITISH JOURNAL OF RADIOLOGY, 2022, 95 (1138):
  • [6] Liver virtual non-enhanced CT with dual-source, dual-energy CT: a preliminary study
    Long-Jiang Zhang
    Jin Peng
    Sheng-Yong Wu
    Z. Jane Wang
    Xin-Sheng Wu
    Chang-Sheng Zhou
    Xue-Man Ji
    Guang-Ming Lu
    European Radiology, 2010, 20 : 2257 - 2264
  • [7] Task-Based Optimal Dose Partitioning in Dual-Source Dual-Energy CT for Virtual Non-Contrast and Iodine Imaging
    Long, L.
    McCollough, C.
    Yu, L.
    MEDICAL PHYSICS, 2018, 45 (06) : E675 - E675
  • [8] Liver virtual non-enhanced CT with dual-source, dual-energy CT: a preliminary study
    Zhang, Long-Jiang
    Peng, Jin
    Wu, Sheng-Yong
    Wang, Z. Jane
    Wu, Xin-Sheng
    Zhou, Chang-Sheng
    Ji, Xue-Man
    Lu, Guang-Ming
    EUROPEAN RADIOLOGY, 2010, 20 (09) : 2257 - 2264
  • [9] Clinical applications of virtual, non-contrast head images derived from dual-source, dual-energy cerebrovascular computed tomography angiography
    Han, D.
    Xie, X. J.
    Wen, L.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2016, 14 (02): : 159 - 163
  • [10] Comparison of Virtual Non-Contrast and True Non-Contrast CT Images Obtained by Dual-Layer Spectral CT in COPD Patients
    Steinhardt, Manuel
    Marka, Alexander W.
    Ziegelmayer, Sebastian
    Makowski, Marcus
    Braren, Rickmer
    Graf, Markus
    Gawlitza, Joshua
    BIOENGINEERING-BASEL, 2024, 11 (04):