Comparison of True and Virtual Non-Contrast Images of Liver Obtained with Single-Source Twin Beam and Dual-Source Dual-Energy CT

被引:0
|
作者
Lee, Jeong Sub [1 ]
Choi, Guk Myung [1 ]
Kim, Bong Soo [1 ]
Ko, Su Yeon [1 ]
Lee, Kyung Ryeol [1 ]
Kim, Jeong Jae [1 ]
Kim, Doo Ri [1 ]
机构
[1] Jeju Natl Univ, Coll Med, Jeju Natl Univ Hosp, Dept Radiol, 15 Aran 13 Gil, Jeju 63241, South Korea
来源
关键词
Radiography; Dual-Energy Scanned Projection; Tomography; X-Ray Computed; Feasibility Studies; COMPUTED-TOMOGRAPHY; ATTENUATION VALUES; NONCONTRAST IMAGES; UNENHANCED IMAGES; ENHANCED CT; ACCURACY; QUALITY;
D O I
10.3348/jksr.2021.0193
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To assess the magnitude of differences between attenuation values of the true non -contrast image (TNC) and virtual non -contrast image (VNC) derived from twin -beam dual -energy CT (tbDECT) and dual-source DECT (dsDECT).<br /> Materials and Methods This retrospective study included 62 patients who underwent liver dynamic DECT with tbDECT ( n = 32) or dsDECT ( n = 30). Arterial VNC (AVNC), portal VNC (PVNC), and delayed VNC (DVNC) were reconstructed using multiphasic DECT. Attenuation values of multiple intra-abdominal organs ( n = 11) on TNCs were subsequently compared to those on multiphasic VNCs. Further, we investigated the percentage of cases with an absolute difference between TNC and VNC of <= 10 Hounsfield units (HU).<br /> Results For the mean attenuation values of TNC and VNC, 33 items for each DECT were compared according to the multiphasic VNCs and organs. More than half of the comparison items for each DECT showed significant differences (tbDECT 17/33; dsDECT 19/33; Bonferroni correction p < 0.0167). The percentage of cases with an absolute difference <= 10 HU was 56.7%, 69.2%, and 78.6% in AVNC, PVNC, and DVNC in tbDECT, respectively, and 70.5%, 78%, and 78% in dsDECT, respectively.<br /> Conclusion VNCs derived from the two DECTs were insufficient to replace TNCs because of the considerable difference in attenuation values.
引用
收藏
页码:170 / 184
页数:15
相关论文
共 50 条
  • [41] Abdominal dual-source dual-energy CT: Uses in clinical practice
    Siegel, Marilyn J.
    Ramirez-Giraldo, Juan Carlos
    Graser, Anno
    APPLIED RADIOLOGY, 2013, 42 (11) : 10 - 16
  • [42] Feasibility study of using virtual non-contrast images derived from dual-energy CT to replace true non-contrast images in patients diagnosed with papillary thyroid carcinoma
    Zhou, Jiang
    Zhou, Yan
    Hu, Hao
    Shen, Mei-Ping
    Ge, Ying-Qian
    Tao, Xin-Wei
    Xu, Xiao-Quan
    Su, Guo-Yi
    Wu, Fei-Yun
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2021, 29 (04) : 711 - 720
  • [43] Image quality optimization and evaluation of linearly mixed images in dual-source, dual-energy CT
    Yu, Lifeng
    Primak, Andrew N.
    Liu, Xin
    McCollough, Cynthia H.
    MEDICAL PHYSICS, 2009, 36 (03) : 1019 - 1024
  • [44] Dual-Source Versus Single-Source Cardiac CT Angiography: Comparison of Diagnostic Image Quality
    Donnino, Robert
    Jacobs, Jill E.
    Doshi, Jay V.
    Hecht, Elizabeth M.
    Kim, Danny C.
    Babb, James S.
    Srichai, Monvadi B.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (04) : 1051 - 1056
  • [45] Dual-source, dual-energy multidetector CT for the evaluation of pancreatic tumours
    Chu, A. J.
    Lee, J. M.
    Lee, Y. J.
    Moon, S. K.
    Han, J. K.
    Choi, B. I.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1018): : E891 - E898
  • [46] Dual-layer spectral computed tomography: Virtual non-contrast in comparison to true non-contrast images
    Sauter, Andreas P.
    Muenzel, Daniela
    Dangelmaier, Julia
    Braren, Rickmer
    Pfeiffer, Franz
    Rummeny, Ernst J.
    Noel, Peter B.
    Fingerle, Alexander A.
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 104 : 108 - 114
  • [47] Virtual Non-Contrast Dual-Energy CT for Proton Therapy Dose Calculation
    Lalonde, A.
    Xie, Y.
    Burgdorf, B.
    O'Reilly, S.
    Ingram, W.
    Yin, L.
    Zou, J.
    Dong, L.
    Bouchard, H.
    Teo, B.
    MEDICAL PHYSICS, 2019, 46 (06) : E127 - E128
  • [48] Dual-Energy CT in Acute Stroke: Could Non-Contrast CT Be Replaced by Virtual Non-Contrast CT? A Feasibility Study
    Herpe, Guillaume
    Platon, Alexandra
    Poletti, Pierre-Alexandre
    Lovblad, Karl O.
    Machi, Paolo
    Becker, Minerva
    Muster, Michel
    Perneger, Thomas
    Guillevin, Remy
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (13)
  • [49] Temporal resolution and motion artifacts in single-source and dual-source cardiac CT
    Schoendube, Harald
    Allmendinger, Thomas
    Stierstorfer, Karl
    Bruder, Herbert
    Flohr, Thomas
    MEDICAL PHYSICS, 2013, 40 (03)
  • [50] Accuracy of Dual-Energy CT Virtual Non-Contrast/unenhanced and Material Density Images: A Phantom Study
    Li, B.
    Pomerleau, M.
    Gupta, A.
    Soto, J.
    Anderson, S.
    MEDICAL PHYSICS, 2020, 47 (06) : E511 - E512