Detection of moderate hepatic steatosis on contrast-enhanced dual-source dual-energy CT: Role and accuracy of virtual non-contrast CT

被引:2
|
作者
Catania, Roberta [1 ]
Jia, Leo [1 ]
Haghshomar, Maryam [1 ]
Miller, Frank H. [1 ]
Borhani, Amir A. [1 ]
机构
[1] Northwestern Univ, Dept Radiol, Feinberg Sch Med, 676 N St Clair St, Arkes Family Pavil, Suite 800, Chicago, IL 60611 USA
关键词
Dual-energy CT; Spectral CT; Virtual non-contrast; Virtual unenhanced; Fatty liver; Steatosis; FATTY LIVER-DISEASE; TOMOGRAPHY PHYSICAL PRINCIPLES; COMPUTED-TOMOGRAPHY; QUANTIFICATION; INFILTRATION; ASSOCIATION; DIAGNOSIS; USAGE; MRI;
D O I
10.1016/j.ejrad.2024.111328
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate diagnostic accuracy of virtual non contrast (VNC) images, based on dual-source dualenergy CT (dsDECT), for detection of at least moderate steatosis and to define a threshold value to make this diagnosis on VNC. Methods: This single-institution retrospective study included patients who had multi-phasic protocol dsDECT. Regions of interests were placed in different segments of the liver and spleen on true non-contrast (TNC), VNC, and portal-venous phase (PVP) images. At least moderate steatosis was defined as liver attenuation (LHU) < 40 HU on TNC. Diagnostic performance of VNC to detect steatosis was determined and the new threshold was tested in a validation cohort. Results: 236 patients were included in training cohort. Mean liver attenuation values were 51.3 +/- 10.8 HU and 58.1 +/- 11.5 HU for TNC and VNC (p < 0.001), with a mean difference (VNC - TNC) of 6.8 +/- 6.9 HU. Correlation between TNC and VNC was strong (r = 0.81, p < 0.001). The AUCs of LHU on VNC for detection of hepatic steatosis were 0.92 (95 % Cl: 0.86-0.98), 0.92 (95 % Cl: 0.87-0.97), 0.92 (95 % Cl: 0.86-0.99), 0.91 (95 % Cl: 0.84-0.97), and 0.87 (95 % Cl: 0.80-0.95) for entire liver, left lateral, left medial, right anterior, and right posterior segments, respectively. VNC had sensitivity/specificity of 100 % /42 % when using a threshold of 40 HU; they were 69 % and 95 %, respectively, when using optimized threshold of 46 HU. This threshold showed similar performance in validation cohort (n = 80). Conclusions: Hepatic attenuation on VNC has promising performance for detection of at least moderate steatosis. Proposed threshold of 46 HU provides high specificity and moderate sensitivity to detect steatosis.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Dual-Energy and Dual-Source CT: Is There a Role in the Abdomen and Pelvis?
    Fletcher, Joel G.
    Takahashi, Naoki
    Hartman, Robert
    Guimaraes, Luis
    Huprich, James E.
    Hough, David M.
    Yu, Lifeng
    McCollough, Cynthia H.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2009, 47 (01) : 41 - +
  • [22] Diagnostic accuracy of virtual non-contrast enhanced dual-energy CT for diagnosis of adrenal adenoma: A systematic review and meta-analysis
    Connolly, Michael J.
    McInnes, Matthew D. F.
    El-Khodary, Mohamed
    McGrath, Trevor A.
    Schieda, Nicola
    EUROPEAN RADIOLOGY, 2017, 27 (10) : 4324 - 4335
  • [23] Renal Stone Quantification in Contrast Enhanced CT Using Convolutional Neural Network Assisted Dual-Energy Virtual Non-Contrast Imaging
    Gong, H.
    Ferrero, A.
    Marsh, J.
    Huber, N.
    Fletcher, J.
    McCollough, C.
    Leng, S.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [24] Diagnostic accuracy of virtual non-contrast enhanced dual-energy CT for diagnosis of adrenal adenoma: A systematic review and meta-analysis
    Michael J. Connolly
    Matthew D. F. McInnes
    Mohamed El-Khodary
    Trevor A. McGrath
    Nicola Schieda
    European Radiology, 2017, 27 : 4324 - 4335
  • [25] Robust quantitative contrast-enhanced dual-energy CT for radiotherapy applications
    Lapointe, Andreanne
    Lalonde, Arthur
    Bahig, Houda
    Carrier, Jean-Francois
    Bedwani, Stephane
    Bouchard, Hugo
    MEDICAL PHYSICS, 2018, 45 (07) : 3086 - 3096
  • [26] Feasibility and Accuracy of Dual-Source Dual-Energy CT for Noninvasive Determination of Hepatic Iron Accumulation
    Joe, Eugene
    Kim, Se Hyung
    Lee, Kyoung Bun
    Jang, Ja-June
    Lee, Jae Young
    Lee, Jeong Min
    Han, Joon Koo
    Choi, Byung Ihn
    RADIOLOGY, 2012, 262 (01) : 126 - 135
  • [27] Quantitative attenuation accuracy of virtual non-enhanced imaging compared to that of true non-enhanced imaging on dual-source dual-energy CT
    Sanaz Javadi
    Sherif Elsherif
    Priya Bhosale
    Corey T. Jensen
    Rick R. Layman
    Megan C. Jacobsen
    Ott Le
    Sun Jia
    Rajan J. Parikh
    Eric P. Tamm
    Abdominal Radiology, 2020, 45 : 1100 - 1109
  • [28] Quantitative attenuation accuracy of virtual non-enhanced imaging compared to that of true non-enhanced imaging on dual-source dual-energy CT
    Javadi, Sanaz
    Elsherif, Sherif
    Bhosale, Priya
    Jensen, Corey T.
    Layman, Rick R.
    Jacobsen, Megan C.
    Le, Ott
    Jia, Sun
    Parikh, Rajan J.
    Tamm, Eric P.
    ABDOMINAL RADIOLOGY, 2020, 45 (04) : 1100 - 1109
  • [29] Combining non-contrast and dual-energy CT improves diagnosis of early gout
    Lee, Seul Ki
    Jung, Joon-Yong
    Jee, Won-Hee
    Lee, Jennifer Jooha
    Park, Sung-Hwan
    EUROPEAN RADIOLOGY, 2019, 29 (03) : 1267 - 1275
  • [30] Dose Savings and Image Quality in Dual-Energy Non-Contrast CT Scans
    Anthony, G.
    Liang, Y.
    MEDICAL PHYSICS, 2021, 48 (06)