Detection of moderate hepatic steatosis on contrast-enhanced dual-source dual-energy CT: Role and accuracy of virtual non-contrast CT

被引:2
|
作者
Catania, Roberta [1 ]
Jia, Leo [1 ]
Haghshomar, Maryam [1 ]
Miller, Frank H. [1 ]
Borhani, Amir A. [1 ]
机构
[1] Northwestern Univ, Dept Radiol, Feinberg Sch Med, 676 N St Clair St, Arkes Family Pavil, Suite 800, Chicago, IL 60611 USA
关键词
Dual-energy CT; Spectral CT; Virtual non-contrast; Virtual unenhanced; Fatty liver; Steatosis; FATTY LIVER-DISEASE; TOMOGRAPHY PHYSICAL PRINCIPLES; COMPUTED-TOMOGRAPHY; QUANTIFICATION; INFILTRATION; ASSOCIATION; DIAGNOSIS; USAGE; MRI;
D O I
10.1016/j.ejrad.2024.111328
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate diagnostic accuracy of virtual non contrast (VNC) images, based on dual-source dualenergy CT (dsDECT), for detection of at least moderate steatosis and to define a threshold value to make this diagnosis on VNC. Methods: This single-institution retrospective study included patients who had multi-phasic protocol dsDECT. Regions of interests were placed in different segments of the liver and spleen on true non-contrast (TNC), VNC, and portal-venous phase (PVP) images. At least moderate steatosis was defined as liver attenuation (LHU) < 40 HU on TNC. Diagnostic performance of VNC to detect steatosis was determined and the new threshold was tested in a validation cohort. Results: 236 patients were included in training cohort. Mean liver attenuation values were 51.3 +/- 10.8 HU and 58.1 +/- 11.5 HU for TNC and VNC (p < 0.001), with a mean difference (VNC - TNC) of 6.8 +/- 6.9 HU. Correlation between TNC and VNC was strong (r = 0.81, p < 0.001). The AUCs of LHU on VNC for detection of hepatic steatosis were 0.92 (95 % Cl: 0.86-0.98), 0.92 (95 % Cl: 0.87-0.97), 0.92 (95 % Cl: 0.86-0.99), 0.91 (95 % Cl: 0.84-0.97), and 0.87 (95 % Cl: 0.80-0.95) for entire liver, left lateral, left medial, right anterior, and right posterior segments, respectively. VNC had sensitivity/specificity of 100 % /42 % when using a threshold of 40 HU; they were 69 % and 95 %, respectively, when using optimized threshold of 46 HU. This threshold showed similar performance in validation cohort (n = 80). Conclusions: Hepatic attenuation on VNC has promising performance for detection of at least moderate steatosis. Proposed threshold of 46 HU provides high specificity and moderate sensitivity to detect steatosis.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Combining non-contrast and dual-energy CT improves diagnosis of early gout
    Seul Ki Lee
    Joon-Yong Jung
    Won-Hee Jee
    Jennifer Jooha Lee
    Sung-Hwan Park
    European Radiology, 2019, 29 : 1267 - 1275
  • [32] Incremental diagnostic value of virtual non-contrast dual-energy CT for the diagnosis of choledocholithiasis over conventional unenhanced CT
    Xiao, Chang -Hui
    Liu, Peng
    Zhang, Hui -Hui
    Yang, Fan
    Chen, Xiang
    Huang, Feng
    Liu, Jian-bin
    Tan, Xian-Zheng
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2024, 105 (7-8) : 292 - 298
  • [33] Virtual versus true non-contrast dual-energy CT imaging for the diagnosis of aortic intramural hematoma
    Salim Si-Mohamed
    Nicolas Dupuis
    Valérie Tatard-Leitman
    David Rotzinger
    Sara Boccalini
    Matthias Dion
    Alain Vlassenbroek
    Philippe Coulon
    Yoad Yagil
    Nadav Shapira
    Philippe Douek
    Loic Boussel
    European Radiology, 2019, 29 : 6762 - 6771
  • [34] Virtual versus true non-contrast dual-energy CT imaging for the diagnosis of aortic intramural hematoma
    Si-Mohamed, Salim
    Dupuis, Nicolas
    Tatard-Leitman, Valerie
    Rotzinger, David
    Boccalini, Sara
    Dion, Matthias
    Vlassenbroek, Alain
    Coulon, Philippe
    Yagil, Yoad
    Shapira, Nadav
    Douek, Philippe
    Boussel, Loic
    EUROPEAN RADIOLOGY, 2019, 29 (12) : 6762 - 6771
  • [35] Accuracy of virtual non-contrast images with different algorithms in dual-energy computed tomography
    Takane, Yumi
    Sato, Kazuhiro
    Kageyama, Ryota
    Takano, Hirokazu
    Kayano, Shingo
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2022, 15 (03) : 234 - 244
  • [36] Accuracy of virtual non-contrast images with different algorithms in dual-energy computed tomography
    Yumi Takane
    Kazuhiro Sato
    Ryota Kageyama
    Hirokazu Takano
    Shingo Kayano
    Radiological Physics and Technology, 2022, 15 : 234 - 244
  • [37] Dual-energy contrast-enhanced mammography
    Travieso Aja, M. M.
    Rodriguez Rodriguez, M.
    Mayon Hernandez, S.
    Vega Benitez, V.
    Luzardo, O. P.
    RADIOLOGIA, 2014, 56 (05): : 390 - 399
  • [38] Clinical applications of virtual, non-contrast head images derived from dual-source, dual-energy cerebrovascular computed tomography angiography
    Han, D.
    Xie, X. J.
    Wen, L.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2016, 14 (02): : 159 - 163
  • [39] Dual-energy contrast-enhanced CT to evaluate scaphoid osteonecrosis with surgical correlation
    Pianta, Marcus
    McCombe, David
    Slavin, John
    Hendry, Shona
    Perera, Warren
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2019, 63 (01) : 69 - 75
  • [40] Contrast-Enhanced Dual-Energy Cone-Beam CT for Musculoskeletal Radiology
    Zbijewski, W.
    Stayman, J.
    Ding, Y.
    Prakash, P.
    Machado, A.
    Carrino, J.
    Siewerdsen, J.
    MEDICAL PHYSICS, 2011, 38 (06)