Objective: To evaluate the influence of the validation method on the diagnostic accuracy and the relative comparison of eight radiographic systems for caries detection. Methods: Three hundred and thirty-eight approximal and 145 occlusal surfaces were radiographed under standardised conditions using six CCD-based sensor systems: MPDx (Dental/Medical Diagnostic Systems Inc., Woodland Hills, CA, USA), Dixi (Planmeca, Helsinki, Finland), Sidexis (Sirona, Bensheim, Germany), RVG(old) (Trophy, Paris, France, 1994 model), RVG(new) (Trophy, Paris, France, 2000 model) and Visualix (Gendex, Milan, Italy) and two film systems: Ektaspeed Plus and Insight (Eastman Kodak, Rochester, NY, USA). Four observers examined the radiographs for approximal and occlusal caries using a five-point confidence scale. The presence of caries was validated histologically and radiographically. Diagnostic accuracy was evaluated using ROC curve areas (A(z)). Results: For both approximal and occlusal caries the mean A(z) of the eight radiographic systems was significantly higher using radiographic than histological validation (P<0.001). Using histological validation for approximal caries, Dixi (A(z)=0.71) and Ektaspeed Plus (A(z)=0.7) were not significantly different, but Dixi was significantly more accurate than the other digital systems and the Insight film. Using radiographic validation for approximal caries, Ektaspeed Plus (A(z)=0.87) was significantly more accurate than Dixi (A(z)=0.82). Dixi was significantly more accurate than MPDx (A(z) = 0.74), RVG(old) (A(z) = 0.77), RVG(new) (A(z) = 0.77) and Visualix (A(z)= 0.76). Corresponding variations were found for occlusal caries depending on the validation method. Using histological validation, MPDx (A(z)=0.76) was significantly less accurate than Dixi (A(z)=0.81), Sidexis (A(z)=0.8), Ektaspeed Plus (A(z)=0.82) and Insight (A(z)=0.81). Using radiographic validation, MPDx (A(z)=0.83) was also significantly less accurate than RVG(old) (A(z)= 0.89) and RVG(new) (A(z) = 0.9). Conclusion: A(z) obtained from radiographic validation was significantly higher than A(z) obtained from histological validation. Comparison of the diagnostic efficacy for caries of the eight radiographic systems was strongly influenced by the validation method.
引用
收藏
页码:44 / 49
页数:6
相关论文
共 46 条
  • [31] An alternative method for global and partial comparison of two diagnostic systems based on ROC curves
    Braga, A. C.
    Costa, L.
    Oliveira, P.
    JOURNAL OF STATISTICAL COMPUTATION AND SIMULATION, 2013, 83 (02) : 307 - 325
  • [32] In vitro comparison of accuracy between conventional and digital impression using elastomeric materials and two intra-oral scanning devices
    Palantza, Eirini
    Sykaras, Nikitas
    Zoidis, Panagiotis
    Kourtis, Stefanos
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2024, 36 (08) : 1179 - 1198
  • [33] Influence of intraoral conditions on the accuracy of digital and conventional implant impression techniques for two-implant-supported fixed dental prostheses
    Ma, Yun
    Guo, Yong-qing
    Jiang, Lei
    Yu, Hao
    JOURNAL OF PROSTHODONTIC RESEARCH, 2023, 67 (04) : 633 - 640
  • [34] Effect of delayed scanning on imaging and on the diagnostic accuracy of vertical root fractures in two photostimulable phosphor plates digital systems
    Nascimento, H. A. R.
    Visconti, M. A. P. G.
    Ferreira, L. M.
    Suarez, M. A.
    Haiter Neto, F.
    Freitas, D. Q.
    INTERNATIONAL ENDODONTIC JOURNAL, 2016, 49 (10) : 973 - 979
  • [35] Diagnostic accuracy of contrast-enhanced spectral mammography in comparison to conventional full-field digital mammography in a population of women with dense breasts
    Miki Mori
    Sadako Akashi-Tanaka
    Satoko Suzuki
    Murasaki Ikeda Daniels
    Chie Watanabe
    Masanori Hirose
    Seigo Nakamura
    Breast Cancer, 2017, 24 : 104 - 110
  • [36] Diagnostic accuracy of contrast-enhanced spectral mammography in comparison to conventional full-field digital mammography in a population of women with dense breasts
    Mori, Miki
    Akashi-Tanaka, Sadako
    Suzuki, Satoko
    Daniels, Murasaki Ikeda
    Watanabe, Chie
    Hirose, Masanori
    Nakamura, Seigo
    BREAST CANCER, 2017, 24 (01) : 104 - 110
  • [37] Diagnostic Accuracy of GeneXpert MTB/RIF Assay in Comparison to Conventional Drug Susceptibility Testing Method for the Diagnosis of Multidrug-Resistant Tuberculosis
    Pandey, Pratikshya
    Pant, Narayan Dutt
    Rijal, Komal Raj
    Shrestha, Bhawana
    Kattel, Sirita
    Banjara, Megha Raj
    Maharjan, Bhagwan
    Rajendra, K. C.
    PLOS ONE, 2017, 12 (01):
  • [38] Computer-assisted diagnosis (CAD) in mammography: comparison of diagnostic accuracy of a new algorithm (CyclopusA®, Medicad) with two commercial systems
    Ciatto, S.
    Cascio, D.
    Fauci, F.
    Magro, R.
    Raso, G.
    Ienzi, R.
    Martinelli, F.
    Simone, M. Vasile
    RADIOLOGIA MEDICA, 2009, 114 (04): : 626 - 635
  • [39] Comparison of the Accuracy of Two Conventional Phenotypic Methods and Two MALDI-TOF MS Systems with That of DNA Sequencing Analysis for Correctly Identifying Clinically Encountered Yeasts
    Chao, Qiao-Ting
    Lee, Tai-Fen
    Teng, Shih-Hua
    Peng, Li-Yun
    Chen, Ping-Hung
    Teng, Lee-Jene
    Hsueh, Po-Ren
    PLOS ONE, 2014, 9 (10):
  • [40] Detection and characterization of breast lesions in a selective diagnostic population: diagnostic accuracy study for comparison between one-view digital breast tomosynthesis and two-view full-field digital mammography
    Chae, Eun Young
    Kim, Hak Hee
    Cha, Joo Hee
    Shin, Hee Jung
    Choi, Woo Jung
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1062):