Influence of the validation method on diagnostic accuracy for caries. A comparison of six digital and two conventional radiographic systems

被引:45
|
作者
Hintze, H [1 ]
Wenzel, A [1 ]
机构
[1] Aarhus Univ, Royal Dent Coll, Dept Oral Radiol, Fac Hlth Sci, DK-8000 Aarhus C, Denmark
关键词
digital radiography; dental; dental caries; diagnostic test; ROC curve;
D O I
10.1038/sj.dmfr.4600645
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To evaluate the influence of the validation method on the diagnostic accuracy and the relative comparison of eight radiographic systems for caries detection. Methods: Three hundred and thirty-eight approximal and 145 occlusal surfaces were radiographed under standardised conditions using six CCD-based sensor systems: MPDx (Dental/Medical Diagnostic Systems Inc., Woodland Hills, CA, USA), Dixi (Planmeca, Helsinki, Finland), Sidexis (Sirona, Bensheim, Germany), RVG(old) (Trophy, Paris, France, 1994 model), RVG(new) (Trophy, Paris, France, 2000 model) and Visualix (Gendex, Milan, Italy) and two film systems: Ektaspeed Plus and Insight (Eastman Kodak, Rochester, NY, USA). Four observers examined the radiographs for approximal and occlusal caries using a five-point confidence scale. The presence of caries was validated histologically and radiographically. Diagnostic accuracy was evaluated using ROC curve areas (A(z)). Results: For both approximal and occlusal caries the mean A(z) of the eight radiographic systems was significantly higher using radiographic than histological validation (P<0.001). Using histological validation for approximal caries, Dixi (A(z)=0.71) and Ektaspeed Plus (A(z)=0.7) were not significantly different, but Dixi was significantly more accurate than the other digital systems and the Insight film. Using radiographic validation for approximal caries, Ektaspeed Plus (A(z)=0.87) was significantly more accurate than Dixi (A(z)=0.82). Dixi was significantly more accurate than MPDx (A(z) = 0.74), RVG(old) (A(z) = 0.77), RVG(new) (A(z) = 0.77) and Visualix (A(z)= 0.76). Corresponding variations were found for occlusal caries depending on the validation method. Using histological validation, MPDx (A(z)=0.76) was significantly less accurate than Dixi (A(z)=0.81), Sidexis (A(z)=0.8), Ektaspeed Plus (A(z)=0.82) and Insight (A(z)=0.81). Using radiographic validation, MPDx (A(z)=0.83) was also significantly less accurate than RVG(old) (A(z)= 0.89) and RVG(new) (A(z) = 0.9). Conclusion: A(z) obtained from radiographic validation was significantly higher than A(z) obtained from histological validation. Comparison of the diagnostic efficacy for caries of the eight radiographic systems was strongly influenced by the validation method.
引用
收藏
页码:44 / 49
页数:6
相关论文
共 46 条
  • [21] A comparison of the diagnostic accuracy of bitewing, periapical, unfiltered and filtered digital panoramic images for approximal caries detection in posterior teeth
    Akarslan, Z. Z.
    Akdevelioglu, M.
    Gungor, K.
    Erten, H.
    DENTOMAXILLOFACIAL RADIOLOGY, 2008, 37 (08) : 458 - 463
  • [22] Two- and three-dimensional imaging modalities for the detection of caries.: A comparison between film, digital radiography and tuned aperture computed tomography (TACT™)
    Abreu, M
    Tyndall, DA
    Platin, E
    Ludlow, JB
    Phillips, C
    DENTOMAXILLOFACIAL RADIOLOGY, 1999, 28 (03) : 152 - 157
  • [23] DIGITAL THERMAL CORONARY ANGIOGRAPHY - DEVELOPMENT AND VALIDATION OF THE METHOD IN COMPARISON TO CONVENTIONAL CINE CORONARY ANGIOGRAPHY
    MOHR, FW
    GRUNDFEST, W
    LITVACK, F
    FORRESTER, J
    MATLOFF, J
    KIRCHHOFF, PG
    ZEITSCHRIFT FUR KARDIOLOGIE, 1989, 78 (07): : 441 - 452
  • [24] Comparison of four digital and one conventional radiographic image systems for the chest in a patient study with subsequent system optimization
    Redlich, U
    Hoeschen, C
    Effenberger, O
    Fessel, A
    Preuss, H
    Reissberg, S
    Scherlach, C
    Döhring, W
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2005, 177 (02): : 272 - 278
  • [25] Comparison of three rapid influenza diagnostic tests with digital readout systems and one conventional rapid influenza diagnostic test
    Ryu, Sook Won
    Suh, In Bum
    Ryu, Se-Min
    Shin, Kyu Sung
    Kim, Hyon-Suk
    Kim, Juwon
    Uh, Young
    Yoon, Kap Jun
    Lee, Jong-Han
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2018, 32 (02)
  • [26] Diagnostic accuracy of direct digital dental radiography for the detection of periapical bone lesions - Overall comparison between conventional and direct digital radiography
    Kullendorff, B
    Nilsson, M
    Rohlin, M
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1996, 82 (03): : 344 - 350
  • [27] MEASUREMENT ACCURACY - COMPARISON OF 2 INTRAORAL DIGITAL RADIOGRAPHIC SYSTEMS, RADIOVISIOGRAPHY-S AND FLASHDENT, WITH ANALOG FILM
    SCARFE, WC
    NORTON, S
    FARMAN, AG
    DENTOMAXILLOFACIAL RADIOLOGY, 1995, 24 (04) : 215 - 220
  • [28] The clinical accuracy of single crowns exclusively fabricated by digital workflow—the comparison of two systems
    Petya K. Brawek
    Stefan Wolfart
    Lutz Endres
    Armin Kirsten
    Sven Reich
    Clinical Oral Investigations, 2013, 17 : 2119 - 2125
  • [29] DIAGNOSTIC-ACCURACY OF CORONARY ANGIOGRAPHY UTILIZING COMPUTER-BASED DIGITAL SUBTRACTION METHODS - COMPARISON TO CONVENTIONAL CINEANGIOGRAPHY
    GOLDBERG, HL
    MOSES, JW
    FISHER, J
    TAMARI, I
    BORER, JS
    CHEST, 1986, 90 (06) : 793 - 797
  • [30] The clinical accuracy of single crowns exclusively fabricated by digital workflow-the comparison of two systems
    Brawek, Petya K.
    Wolfart, Stefan
    Endres, Lutz
    Kirsten, Armin
    Reich, Sven
    CLINICAL ORAL INVESTIGATIONS, 2013, 17 (09) : 2119 - 2125