Computer-assisted diagnosis (CAD) in mammography: comparison of diagnostic accuracy of a new algorithm (CyclopusA®, Medicad) with two commercial systems

被引:0
|
作者
Ciatto, S. [4 ]
Cascio, D. [1 ]
Fauci, F. [1 ]
Magro, R. [1 ]
Raso, G. [1 ]
Ienzi, R. [2 ]
Martinelli, F. [4 ]
Simone, M. Vasile [3 ]
机构
[1] Univ Palermo, Dipartimento Fis & Tecnol Relat, Palermo, Italy
[2] Policlin Palermo, Ist Radiol, Palermo, Italy
[3] MEDICAD Srl, Palermo, Italy
[4] Ist Sci Prevenz Oncol, I-50133 Florence, Italy
来源
RADIOLOGIA MEDICA | 2009年 / 114卷 / 04期
关键词
Breast carcinoma; Computer-assisted diagnosis; Mammography; BREAST SCREENING-PROGRAM; AIDED DETECTION SYSTEM; CANCER-DETECTION; MORTALITY; IMPACT; RATES;
D O I
10.1007/s11547-009-0396-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The study compares the diagnostic accuracy (correct identification of cancer) of a new computer-assisted diagnosis (CAD) system (Cyclopus) with two other commercial systems (R2 and CADx). Cyclopus was tested on a set of 120 mammograms on which the two compared commercial systems had been previously tested. The set consisted of mammograms reported as negative, preceding 31 interval cancers reviewed as screening error or minimal sign, and of 89 verified negative controls randomly selected from the same screening database. Cyclopus sensitivity was 74.1% (R2=54.8%; CADx=41.9%) and was higher for interval cancers reviewed as screening error (90.9%; R2=54.5%; CADx=81.8%) compared with those reviewed as minimal sign (65.0%; R2=55.0%; CADx=20.0%). Specificity was 15.7% (R2=29.2%; CADx=17.9%). Overall accuracy was 30.8% (R2=35.8%; CADx=24.1%). The positive predictive value of a case with CAD marks [regions of interest (ROI)] was 23.4% (23/98; R2=16.0%; CADx=15.1%). Average ROI number per view among negative controls was 1.13 (R2=0.93; CADx=0.99). Cyclopus was more sensitive for masses compared with isolated microcalcifications (208 vs 62 ROI; R2=90 vs 213; CADx=192 vs 130). Compared with two other commercial systems, Cyclopus was more sensitive (R2 p=0.14; CADx p=0.02) and less specific (R2 p=0.02; CADx p=0.64).
引用
收藏
页码:626 / 635
页数:10
相关论文
共 31 条
  • [1] Computer-assisted diagnosis (CAD) in mammography: Comparison of diagnostic accuracy of a new algorithm (Cyclopus®, Medicad) with two commercial systems [Diagnosi assistita da computer (CAD) in mammografia. Confronto di accuratezza diagnostica di un nuovo algoritmo (Cyclopus®, Medical) con due sistemi commerciali]
    Ciatto S.
    Cascio D.
    Fauci F.
    Magro R.
    Raso G.
    Ienzi R.
    Martinelli F.
    Simone M.V.
    La radiologia medica, 2009, 114 (4) : 626 - 635
  • [2] Comparison of Two Commercial CAD Systems for Digital Mammography
    Leon, Stephanie
    Brateman, Libby
    Honeyman-Buck, Janice
    Marshall, Julia
    JOURNAL OF DIGITAL IMAGING, 2009, 22 (04) : 421 - 423
  • [3] Comparison of Two Commercial CAD Systems for Digital Mammography
    Stephanie Leon
    Libby Brateman
    Janice Honeyman-Buck
    Julia Marshall
    Journal of Digital Imaging, 2009, 22 : 421 - 423
  • [4] Computer-assisted diagnosis (CAD) in mammography: Does it help the junior and the senior radiologist?
    Balleyguier, C
    Malan, S
    Taourel, P
    Chabriais, J
    Helenon, O
    Menu, YM
    RADIOLOGY, 2001, 221 : 520 - 520
  • [5] A Computer-Assisted Diagnostic (CAD) of Screening Mammography to Detect Breast Cancer Without a Surgical Biopsy
    Bouarara, Hadj Ahmed
    INTERNATIONAL JOURNAL OF SOFTWARE SCIENCE AND COMPUTATIONAL INTELLIGENCE-IJSSCI, 2019, 11 (04): : 31 - 49
  • [6] Diagnostic accuracy of commercial system for computer-assisted detection (CADx) as an adjunct to interpretation of mammograms
    Menna, S
    Di Virgilio, MR
    Burke, P
    Frigerio, A
    Boglione, E
    Ciccarelli, G
    Di Filippo, S
    Garretti, L
    RADIOLOGIA MEDICA, 2005, 110 (04): : 334 - 340
  • [7] Improvement of the diagnostic accuracy in computer-assisted differential diagnosis for wide QRS premature complexes
    Katoh, T
    Yodogawa, K
    Ohno, T
    Hayakawa, H
    CIRCULATION JOURNAL, 2003, 67 (12) : 1036 - 1040
  • [8] COMPUTER-ASSISTED DIAGNOSIS AND COMPUTER CONSULTATION IN NEUROLOGY - PRELIMINARY TESTING OF DIAGNOSTIC-ACCURACY FOR THE NEUROLOGIST SYSTEM
    CATANZARITE, VA
    GREENBURG, AG
    BREMERMANN, HJ
    INTERNATIONAL JOURNAL OF NEUROSCIENCE, 1981, 13 (01) : 43 - 54
  • [9] Diagnostic Accuracy of Computer-Assisted Electrocardiography in the Diagnosis of Left Ventricular Hypertrophy in Left Bundle Branch Block
    Rodriguez-Padial, Luis
    Rodriguez-Picon, Blanca
    Jerez-Valero, Miguel
    Casares-Medrano, Julio
    Akerstroem, Finn O.
    Calderon, Alberto
    Barrios, Vivencio
    Sarria-Santamera, Antonio
    Gonzalez-Juanatey, Jose R.
    Coca, Antonio
    Andres, Josep
    Ruiz-Baena, Jessica
    REVISTA ESPANOLA DE CARDIOLOGIA, 2012, 65 (01): : 38 - 46
  • [10] Clinical Value of Computer-Assisted Analysis in MR Mammography. A Comparison between two Systems and three Observers with Different Levels of Experience
    Renz, D. M.
    Baltzer, P. A. T.
    Kullnig, P. E.
    Bottcher, J.
    Vag, T.
    Gajda, M.
    Camara, O.
    Runnebaum, I. B.
    Kaiser, W. A.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2008, 180 (11): : 968 - 976