Computer-assisted diagnosis (CAD) in mammography: comparison of diagnostic accuracy of a new algorithm (CyclopusA®, Medicad) with two commercial systems

被引:0
|
作者
Ciatto, S. [4 ]
Cascio, D. [1 ]
Fauci, F. [1 ]
Magro, R. [1 ]
Raso, G. [1 ]
Ienzi, R. [2 ]
Martinelli, F. [4 ]
Simone, M. Vasile [3 ]
机构
[1] Univ Palermo, Dipartimento Fis & Tecnol Relat, Palermo, Italy
[2] Policlin Palermo, Ist Radiol, Palermo, Italy
[3] MEDICAD Srl, Palermo, Italy
[4] Ist Sci Prevenz Oncol, I-50133 Florence, Italy
来源
RADIOLOGIA MEDICA | 2009年 / 114卷 / 04期
关键词
Breast carcinoma; Computer-assisted diagnosis; Mammography; BREAST SCREENING-PROGRAM; AIDED DETECTION SYSTEM; CANCER-DETECTION; MORTALITY; IMPACT; RATES;
D O I
10.1007/s11547-009-0396-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The study compares the diagnostic accuracy (correct identification of cancer) of a new computer-assisted diagnosis (CAD) system (Cyclopus) with two other commercial systems (R2 and CADx). Cyclopus was tested on a set of 120 mammograms on which the two compared commercial systems had been previously tested. The set consisted of mammograms reported as negative, preceding 31 interval cancers reviewed as screening error or minimal sign, and of 89 verified negative controls randomly selected from the same screening database. Cyclopus sensitivity was 74.1% (R2=54.8%; CADx=41.9%) and was higher for interval cancers reviewed as screening error (90.9%; R2=54.5%; CADx=81.8%) compared with those reviewed as minimal sign (65.0%; R2=55.0%; CADx=20.0%). Specificity was 15.7% (R2=29.2%; CADx=17.9%). Overall accuracy was 30.8% (R2=35.8%; CADx=24.1%). The positive predictive value of a case with CAD marks [regions of interest (ROI)] was 23.4% (23/98; R2=16.0%; CADx=15.1%). Average ROI number per view among negative controls was 1.13 (R2=0.93; CADx=0.99). Cyclopus was more sensitive for masses compared with isolated microcalcifications (208 vs 62 ROI; R2=90 vs 213; CADx=192 vs 130). Compared with two other commercial systems, Cyclopus was more sensitive (R2 p=0.14; CADx p=0.02) and less specific (R2 p=0.02; CADx p=0.64).
引用
收藏
页码:626 / 635
页数:10