Finite element biphasic indentation of cartilage: a comparison of experimental indenter and physiological contact geometries

被引:27
|
作者
Warner, MD [1 ]
Taylor, WR [1 ]
Clift, SE [1 ]
机构
[1] Univ Bath, Dept Mech Engn, Bath BA2 7AY, Avon, England
关键词
biphasic; finite element modelling; cartilage; indenter; contact geometries;
D O I
10.1243/0954411011536082
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In experimental cartilage indentation studies, the indenter is typically a plane-ended or hemispherically ended cylinder and can be either porous or non-porous. Joints such as the hip and knee, however, have much higher radii of curvature than those used in experimental indentation testing. In order to interpret the results from such testing in a physiological context it is therefore useful to explore the effect of contact geometry on the pore pressure and strain distribution generated in the cartilage layer. Articular cartilage can be described as a saturated porous medium. and can be considered a biphasic material consisting of a porous, permeable solid matrix, and an interstitial fluid phase. This behaviour has been predicted in this Study using the ABAQUS soils consolidation procedure. Four contact geometries were modelled: two typical experimental configurations (5 mm radii cylindrical indenter and hemispherical indenters) and two effective radii representative of the hip and knee (20 and 100 mm). A 10 per cent deformation. or a load of 0.9 kN was applied over a ramp time of 2 s, which was then maintained for a further 100 s. The porous indenter generated less pore pressure compared with the equivalent non-porous indenter and produced higher values of compressive strain in the solid matrix. The predictions made using the cylindrical indenters. porous and nonporous. were dominated by the concentrations at the edge of the indenter and overestimated the peak compressive strain in the tissue by a factor of 21 and a factor of 14 respectively when compared with the hip model. The hemispherical indenter predicted peak strains in similar positions to those predicted using physiological radii. however, the magnitude was overestimated by a factor of 2.3 when compared with the knee and by 5.7 when compared with the hip. The pore pressure throughout the cartilage layer reduced significantly as the radius of the indenter was increased.
引用
收藏
页码:487 / 496
页数:10
相关论文
共 50 条
  • [41] Study of ratcheting by the indentation fatigue method with a flat cylindrical indenter. Part II. Finite element simulation
    Xu B.X.
    Yue Z.F.
    Journal of Materials Research, 2007, 22 (1) : 186 - 192
  • [42] Hydrostatic pressurization and depletion of trapped lubricant pool during creep and sliding contact of a rippled indenter against a biphasic articular cartilage layer
    Soltz, Michael A.
    Ateshian, Gerard A.
    American Society of Mechanical Engineers, Applied Mechanics Division, AMD, 2000, 242 : 243 - 253
  • [43] Finite element model based elastoplastic contact model and some aspects on indentation response
    Mayuram, M. M.
    MATERIALS SCIENCE AND TECHNOLOGY, 2012, 28 (9-10) : 1045 - 1050
  • [44] An augmented Lagrangian finite element formulation for 3D contact of biphasic tissues
    Guo, Hongqiang
    Spilker, Robert L.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2014, 17 (11) : 1206 - 1216
  • [45] Biphasic finite element contact analysis of the knee joint using an augmented Lagrangian method
    Guo, Hongqiang
    Maher, Suzanne A.
    Spilker, Robert L.
    MEDICAL ENGINEERING & PHYSICS, 2013, 35 (09) : 1313 - 1320
  • [46] Finite element simulation and experimental determination of interfacial adhesion properties by wedge indentation
    Chen, L.
    Yeap, K. B.
    Zeng, K. Y.
    Liu, G. R.
    PHILOSOPHICAL MAGAZINE, 2009, 89 (17) : 1395 - 1413
  • [47] Validation of a finite element model of the human elbow for determining cartilage contact mechanics
    Willing, Ryan T.
    Lalone, Emily A.
    Shannon, Hannah
    Johnson, James A.
    King, Graham J. W.
    JOURNAL OF BIOMECHANICS, 2013, 46 (10) : 1767 - 1771
  • [48] Validation of finite element predictions of cartilage contact pressure in the human hip joint
    Anderson, Andrew E.
    Ellis, Benjamin J.
    Maas, Steve A.
    Peters, Christopher L.
    Weiss, Jeffrey A.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2008, 130 (05):
  • [49] Experimental and finite element analysis of large-strain indentation of polymeric solids
    Lu, Y. C.
    Shinozaki, D. M.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION 2007, VOL 10, PTS A AND B: MECHANICS OF SOLIDS AND STRUCTURES, 2008, : 497 - 500
  • [50] Physical modeling and arbitrary Lagrangian–Eulerian finite element analysis of indentation of a sensitive clay by a flat-ended axisymmetrical indenter
    Ghassan Abou-Samra
    Mireille Sandrine Ewane
    Vincenzo Silvestri
    International Journal of Geo-Engineering, 2020, 11