Finite element biphasic indentation of cartilage: a comparison of experimental indenter and physiological contact geometries

被引:27
|
作者
Warner, MD [1 ]
Taylor, WR [1 ]
Clift, SE [1 ]
机构
[1] Univ Bath, Dept Mech Engn, Bath BA2 7AY, Avon, England
关键词
biphasic; finite element modelling; cartilage; indenter; contact geometries;
D O I
10.1243/0954411011536082
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In experimental cartilage indentation studies, the indenter is typically a plane-ended or hemispherically ended cylinder and can be either porous or non-porous. Joints such as the hip and knee, however, have much higher radii of curvature than those used in experimental indentation testing. In order to interpret the results from such testing in a physiological context it is therefore useful to explore the effect of contact geometry on the pore pressure and strain distribution generated in the cartilage layer. Articular cartilage can be described as a saturated porous medium. and can be considered a biphasic material consisting of a porous, permeable solid matrix, and an interstitial fluid phase. This behaviour has been predicted in this Study using the ABAQUS soils consolidation procedure. Four contact geometries were modelled: two typical experimental configurations (5 mm radii cylindrical indenter and hemispherical indenters) and two effective radii representative of the hip and knee (20 and 100 mm). A 10 per cent deformation. or a load of 0.9 kN was applied over a ramp time of 2 s, which was then maintained for a further 100 s. The porous indenter generated less pore pressure compared with the equivalent non-porous indenter and produced higher values of compressive strain in the solid matrix. The predictions made using the cylindrical indenters. porous and nonporous. were dominated by the concentrations at the edge of the indenter and overestimated the peak compressive strain in the tissue by a factor of 21 and a factor of 14 respectively when compared with the hip model. The hemispherical indenter predicted peak strains in similar positions to those predicted using physiological radii. however, the magnitude was overestimated by a factor of 2.3 when compared with the knee and by 5.7 when compared with the hip. The pore pressure throughout the cartilage layer reduced significantly as the radius of the indenter was increased.
引用
收藏
页码:487 / 496
页数:10
相关论文
共 50 条
  • [21] ANALYSIS OF THE CONTACT AREA OF SMOOTH AND ROUGH SURFACES IN CONTACT WITH SPHERE INDENTER USING FINITE ELEMENT METHOD
    Kartini
    Saputra, E.
    Ismail, R.
    Jamari, J.
    Bayuseno, A. P.
    3RD BALI INTERNATIONAL SEMINAR ON SCIENCE & TECHNOLOGY (BISSTECH 2015), 2016, 58
  • [22] Estimation of effects of indenter-tip geometry by means of finite element analyses of nano-indentation
    Takagi, S
    Hattori, K
    Seino, Y
    Nakano, H
    JOINT INTERNATIONAL CONFERENCE IMEKO TC3/TC5/TC20, 2002, 1685 : 243 - 247
  • [23] The Effects of Surface Curvature on Cartilage Behaviour in Indentation Test: A Finite Element Study
    Abd Latif, Mohd Juzaila
    Hashim, Nur Hikmah
    Ramlan, Roszaidi
    Mahmud, Jamaluddin
    Jumahat, Aidah
    Kadir, Mohammed Rafiq Abdul
    INTERNATIONAL TRIBOLOGY CONFERENCE MALAYSIA 2013, 2013, 68 : 109 - 115
  • [24] A combination of the finite element analysis and experimental indentation via the cornea
    Karimi, Alireza
    Razaghi, Reza
    Sera, Toshihiro
    Kudo, Susumu
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2019, 90 : 146 - 154
  • [25] A COMPARISON OF HEXAHEDRAL AND TETRAHEDRAL FINITE ELEMENTS FOR BIPHASIC ANALYSIS OF CARTILAGE MICROMECHANICS
    Sibole, Scott
    Bennetts, Craig
    Erdemir, Ahmet
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, PTS A AND B, 2012, : 721 - 722
  • [26] BIPHASIC INDENTATION OF ARTICULAR-CARTILAGE .2. A NUMERICAL ALGORITHM AND AN EXPERIMENTAL-STUDY
    MOW, VC
    GIBBS, MC
    LAI, WM
    ZHU, WB
    ATHANASIOU, KA
    JOURNAL OF BIOMECHANICS, 1989, 22 (8-9) : 853 - 861
  • [27] Comparison of finite element codes for the solution of biphasic poroelastic problems
    Prendergast, P.J.
    van Driel, W.D.
    Kuiper, J.-H.
    Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1996, 210 (02): : 131 - 136
  • [28] A comparison of finite element codes for the solution of biphasic poroelastic problems
    Prendergast, PJ
    vanDriel, WD
    Kuiper, JH
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1997, 211 (02) : 209 - 211
  • [29] A finite element implementation for biphasic contact of hydrated porous media under finite deformation and sliding
    Guo, Hongqiang
    Shah, Mitul
    Spilker, Robert L.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2014, 228 (03) : 225 - 236
  • [30] Finite element based indentation contact analysis of SWCNT nano-composite
    Bhadra, Rakesh
    Jana, Tamonash
    Mitra, Anirban
    Sahoo, Prasanta
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2024, 238 (04) : 1125 - 1141