Finite element biphasic indentation of cartilage: a comparison of experimental indenter and physiological contact geometries

被引:27
|
作者
Warner, MD [1 ]
Taylor, WR [1 ]
Clift, SE [1 ]
机构
[1] Univ Bath, Dept Mech Engn, Bath BA2 7AY, Avon, England
关键词
biphasic; finite element modelling; cartilage; indenter; contact geometries;
D O I
10.1243/0954411011536082
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In experimental cartilage indentation studies, the indenter is typically a plane-ended or hemispherically ended cylinder and can be either porous or non-porous. Joints such as the hip and knee, however, have much higher radii of curvature than those used in experimental indentation testing. In order to interpret the results from such testing in a physiological context it is therefore useful to explore the effect of contact geometry on the pore pressure and strain distribution generated in the cartilage layer. Articular cartilage can be described as a saturated porous medium. and can be considered a biphasic material consisting of a porous, permeable solid matrix, and an interstitial fluid phase. This behaviour has been predicted in this Study using the ABAQUS soils consolidation procedure. Four contact geometries were modelled: two typical experimental configurations (5 mm radii cylindrical indenter and hemispherical indenters) and two effective radii representative of the hip and knee (20 and 100 mm). A 10 per cent deformation. or a load of 0.9 kN was applied over a ramp time of 2 s, which was then maintained for a further 100 s. The porous indenter generated less pore pressure compared with the equivalent non-porous indenter and produced higher values of compressive strain in the solid matrix. The predictions made using the cylindrical indenters. porous and nonporous. were dominated by the concentrations at the edge of the indenter and overestimated the peak compressive strain in the tissue by a factor of 21 and a factor of 14 respectively when compared with the hip model. The hemispherical indenter predicted peak strains in similar positions to those predicted using physiological radii. however, the magnitude was overestimated by a factor of 2.3 when compared with the knee and by 5.7 when compared with the hip. The pore pressure throughout the cartilage layer reduced significantly as the radius of the indenter was increased.
引用
收藏
页码:487 / 496
页数:10
相关论文
共 50 条
  • [31] Finite Element Analysis of Articular Cartilage Model Considering the Configuration and Biphasic Property of the Tissue
    Hosoda, N.
    Sakai, N.
    Sawae, Y.
    Murakami, T.
    13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 1883 - +
  • [32] Finite element simulation of the effect of different initial contact on nano-indentation
    Zhao, Hong-Wei, 1600, Editorial Board of Jilin University (44):
  • [33] A biphasic finite element study on the role of the articular cartilage superficial zone in confined compression
    Guo, Hongqiang
    Maher, Suzanne A.
    Torzilli, Peter A.
    JOURNAL OF BIOMECHANICS, 2015, 48 (01) : 166 - 170
  • [34] Hydrostatic pressurization and depletion of trapped lubricant pool during creep contact of a rippled indenter against a biphasic articular cartilage layer
    Soltz, MA
    Basalo, IM
    Ateshian, GA
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2003, 125 (05): : 585 - 593
  • [35] Finite element simulation of biphasic soft tissue contact with application to the shoulder joint
    Ün, K
    Spilker, RL
    PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 1504 - 1507
  • [36] Finite element predictions of cartilage contact mechanics in hips with retroverted acetabula
    Henak, C. R.
    Carruth, E. D.
    Anderson, A. E.
    Harris, M. D.
    Ellis, B. J.
    Peters, C. L.
    Weiss, J. A.
    OSTEOARTHRITIS AND CARTILAGE, 2013, 21 (10) : 1522 - 1529
  • [37] Finite element prediction of cartilage contact stresses in normal human hips
    Harris, Michael D.
    Anderson, Andrew E.
    Henak, Corinne R.
    Ellis, Benjamin J.
    Peters, Christopher L.
    Weiss, Jeffrey A.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2012, 30 (07) : 1133 - 1139
  • [38] FINITE ELEMENT PREDICTIONS OF CARTILAGE CONTACT MECHANICS IN HIPS WITH RETROVERTED ACETABULA
    Henak, Corinne R.
    Carruth, Eric D.
    Anderson, Andrew E.
    Harris, Michael D.
    Ellis, Benjamin J.
    Peters, Christopher L.
    Weiss, Jeffrey A.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2013, PT A, 2014,
  • [39] Determination of nonlinear fibre-reinforced biphasic poroviscoelastic constitutive parameters of articular cartilage using stress relaxation indentation testing and an optimizing finite element analysis
    Seifzadeh, A.
    Oguamanam, D. C. D.
    Trutiak, N.
    Hurtig, M.
    Papini, M.
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2012, 107 (02) : 315 - 326
  • [40] Study of ratcheting by the indentation fatigue method with a flat cylindrical indenter. Part II. Finite element simulation
    Xu, B. X.
    Yue, Z. F.
    JOURNAL OF MATERIALS RESEARCH, 2007, 22 (01) : 186 - 192