Optimizing the Design of a 2D Array Piezoelectric Micromachined Ultrasound Transducer for 3D Echo Particle Image Velocimetry

被引:0
|
作者
Liu, Jessica [1 ]
Shandas, Robin [1 ]
机构
[1] Univ Colorado, Dept Mech Engn, Boulder, CO 80309 USA
关键词
Echo PIV; pMUTs; MECC; optimization;
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In this paper, we explored the utility of a 21) piezoelectric Micromachined Ultrasound Transducers (pMUTs) for a 3D Echo Particle Image Velocimetry (Echo PM system. The design was achieved by first examining optimal mechanical-electrical coupling coefficient (MECC) for a pMUT subsequently characterizing system performance. A combination of analytical and finite element modeling was used to accomplish the optimization. In the final design, the resonant frequency of each element was 6.0 MHz with a relative bandwidth of 120% in water. By optimizing gaps, the axial resolution and lateral resolution were respectively 0.05mm and 0.35mm in water, which is sufficient for Echo PIV system.
引用
收藏
页码:2329 / 2332
页数:4
相关论文
共 50 条
  • [41] Digital holography particle image velocimetry for 3D flow measurement
    Wei, RJ
    Shen, GX
    Ding, HQ
    OPTICAL TECHNOLOGY AND IMAGE PROCESSING FOR FLUIDS AND SOLIDS DIAGNOSTICS 2002, 2002, 5058 : 61 - 72
  • [42] Volume self-calibration for 3D particle image velocimetry
    Wieneke, B.
    EXPERIMENTS IN FLUIDS, 2008, 45 (04) : 549 - 556
  • [43] A framework for synthetic validation of 3D echocardiographic particle image velocimetry
    Falahatpisheh, Ahmad
    Kheradvar, Arash
    MECCANICA, 2017, 52 (03) : 555 - 561
  • [44] Method and evaluation test design for 2D/3D image segmentation
    Giorgini, F
    Dellepiane, S
    Incardona, G
    Piotto, F
    APPLICATIONS AND SCIENCE OF NEURAL NETWORKS, FUZZY SYSTEMS, AND EVOLUTIONARY COMPUTATION, 1998, 3455 : 332 - 339
  • [45] Volume self-calibration for 3D particle image velocimetry
    B. Wieneke
    Experiments in Fluids, 2008, 45 : 549 - 556
  • [46] Obtaining 3D High-Resolution Underwater Acoustic Images by Synthesizing Virtual Aperture on the 2D Transducer Array of Multibeam Echo Sounder
    Wei, Bo
    Li, Haisen
    Zhou, Tian
    Xing, Siyu
    REMOTE SENSING, 2019, 11 (22)
  • [47] A Front-End Integrated Circuit for a 2D Capacitive Micromachined Ultrasound Transducer (CMUT) Array as a Noninvasive Neural Stimulator
    Seok, Chunkyun
    Wu, Xun
    Yamaner, F. Yalcin
    Oralkan, Omer
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [48] Fetal cardiac ventricular volumes derived from real-time 3D ultrasound using a 2D matrix array transducer
    Tutschek, Boris
    Robertson, Paricia
    Wyatt, Solange
    Sahn, Christine
    Hui, Ling
    Sahn, David
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2006, 195 (06) : S77 - S77
  • [49] Concave 2D Ring Array Transducer for Ultrasound Visual Stimulation of the Brain
    Lu, Jian-Yu
    Lu, Gengxi
    Humayun, Mark
    Zhou, Qifa
    2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,
  • [50] 2D/3D image registration on the GPU
    Kubias A.
    Deinzer F.
    Feldmann T.
    Paulus D.
    Schreiber B.
    Brunner Th.
    Pattern Recognition and Image Analysis, 2008, 18 (03) : 381 - 389