Optimizing the Design of a 2D Array Piezoelectric Micromachined Ultrasound Transducer for 3D Echo Particle Image Velocimetry

被引:0
|
作者
Liu, Jessica [1 ]
Shandas, Robin [1 ]
机构
[1] Univ Colorado, Dept Mech Engn, Boulder, CO 80309 USA
关键词
Echo PIV; pMUTs; MECC; optimization;
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In this paper, we explored the utility of a 21) piezoelectric Micromachined Ultrasound Transducers (pMUTs) for a 3D Echo Particle Image Velocimetry (Echo PM system. The design was achieved by first examining optimal mechanical-electrical coupling coefficient (MECC) for a pMUT subsequently characterizing system performance. A combination of analytical and finite element modeling was used to accomplish the optimization. In the final design, the resonant frequency of each element was 6.0 MHz with a relative bandwidth of 120% in water. By optimizing gaps, the axial resolution and lateral resolution were respectively 0.05mm and 0.35mm in water, which is sufficient for Echo PIV system.
引用
收藏
页码:2329 / 2332
页数:4
相关论文
共 50 条
  • [21] Combining 2D and 3D Device Simulations for Optimizing LDMOS Design
    Lin, Chin-Che
    Sheu, Gene
    Yang, Shao-Ming
    Guo, Yu-Feng
    CHINA SEMICONDUCTOR TECHNOLOGY INTERNATIONAL CONFERENCE 2010 (CSTIC 2010), 2010, 27 (01): : 125 - 129
  • [22] Receive/Transmit Aperture Selection for 3D Ultrasound Imaging with a 2D Matrix Transducer
    Mozaffarzadeh, Moein
    Soozande, Mehdi
    Fool, Fabian
    Pertijs, Michiel A. P.
    Vos, Hendrik J.
    Verweij, Martin D.
    Bosch, Johan G.
    de Jong, Nico
    APPLIED SCIENCES-BASEL, 2020, 10 (15):
  • [23] Performance and Crosstalk Evaluation of 2-D Array Piezoelectric Micromachined Ultrasonic Transducer with 3-D Finite Element Simulation
    He, Le-Ming
    Xu, Wei-Jiang
    Liu, Wen-Juan
    Wang, Xu-Bo
    Zhou, Jia
    Ren, Jun-Yan
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 792 - 795
  • [24] Image scanners: 2D and 3D
    Handley, R.
    Advanced Imaging, 2001, 16 (07) : 28 - 33
  • [25] 2D and 3D image processing
    2D- und 3D-Bildverarbeitung
    Materialpruefung/Materials Testing, 2001, 43 (05):
  • [26] Non-iterative double-frame 2D/3D particle tracking velocimetry
    Fuchs, Thomas
    Hain, Rainer
    Kaehler, Christian J.
    EXPERIMENTS IN FLUIDS, 2017, 58 (09)
  • [27] Non-iterative double-frame 2D/3D particle tracking velocimetry
    Thomas Fuchs
    Rainer Hain
    Christian J. Kähler
    Experiments in Fluids, 2017, 58
  • [28] 3D ultrasound imaging in frequency domain with 1D array transducer
    Han, Zhihui
    Peng, Hu
    Lu, Putian
    ULTRASONICS, 2017, 76 : 28 - 34
  • [29] Simultaneous measurement of 3D velocity and 2D rotation of irregular particle with digital holographic particle tracking velocimetry
    Wu, Yingchun
    Wu, Xuecheng
    Yao, Longchao
    Brunel, Marc
    Coetmellec, Sebastien
    Lebrun, Denis
    Grehan, Gerard
    Cen, Kefa
    POWDER TECHNOLOGY, 2015, 284 : 371 - 378
  • [30] 3D particle tracking velocimetry
    European Space Agency (Brochure) ESA BR, 1999, (BR-154):