Assessment of new small-field detectors against standard-field detectors for practical stereotactic beam data acquisition

被引:112
|
作者
McKerracher, C [1 ]
Thwaites, DI [1 ]
机构
[1] Western Gen Hosp, Edinburgh EH4 2XU, Midlothian, Scotland
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1999年 / 44卷 / 09期
关键词
D O I
10.1088/0031-9155/44/9/303
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Two new detectors (0.015 cm(3) ion chamber from PTW, 0.6 mm diameter diode from Scanditronix AB) designed specifically for use in small stereotactic fields were compared against similar, more routine, detectors (0.125 cm(3) ion chamber; parallel plate chamber, shielded and unshielded diodes and film). Percentage depth doses, tissue maximum ratios, off-axis ratios and relative output factors were compared for circular fields in the 40-12.5 mm diameter range, with a view to identifying the optimum detector for stereotactic beam data acquisition. Practical suggestions for beam data collection and analysis are made, with an emphasis on what is achievable practically in radiotherapy departments where the primary demand is to provide a routine service. No single detector was found to be ideal, and neither of the two new measurement devices had any significant advantages over more routine devices, in the situations measured. Although the new 0.015 cm(3) ion chamber was an improvement on a 0.125 cm(3) ion chamber in the measurement of profiles, it was still too large when compared with a diode. The new small diode had a low signal to noise ratio which made reliable data difficult to extract and its only advantage is possibly improved resolution in fields smaller than the range tested. The use of a larger unshielded diode is recommended for all measurements, with the additional cross-checking of data against at least one small ion chamber and film. A simple method of obtaining reliable output data from the detectors used is explained.
引用
收藏
页码:2143 / 2160
页数:18
相关论文
共 49 条
  • [21] Dosimetric effects on small-field beam-modeling for stereotactic body radiation therapy
    Woong Cho
    Suzy Kim
    Jung-In Kim
    Hong-Gyun Wu
    Joo-Young Jung
    Min-Joo Kim
    Tae-Suk Suh
    Jin-Young Kim
    Jong Won Kim
    Journal of the Korean Physical Society, 2015, 66 : 678 - 693
  • [22] The practical application of scintillation dosimetry in small-field photon-beam radiotherapy
    Burke, Elisa
    Poppinga, Daniela
    Schoenfeld, Andreas A.
    Harder, Dietrich
    Poppe, Bjoern
    Looe, Hui Khee
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2017, 27 (04): : 324 - 333
  • [23] TrueBeam Small Field Dosimetry Using Commercial Plastic Scintillation and Other Stereotactic Detectors
    Pino, R.
    Therriault-Proulx, F.
    Wang, X.
    Yang, J.
    Beddar, S.
    MEDICAL PHYSICS, 2014, 41 (06) : 323 - 323
  • [24] Dosimetric evaluation of a new design small volume detectors for small field high-energy photon beam
    Huh, H. Hyun Do
    Choi, C. Sang Hyoun
    Kim, K. Seong Hoon
    Kim, K. Kum Bae
    Ji, J. Young Hoon
    Lee, L. Chang Yeol
    Kim, K. Woo Chul
    Kim, K. Hun Jeong
    Min, M. Chul Kee
    Cho, C. Kwang Hwan
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S137 - S137
  • [25] Consistency of small-field dosimetry, on and off axis, in beam-matched linacs used for stereotactic radiosurgery
    Munoz, Luis
    Kron, Tomas
    Petasecca, Marco
    Bucci, Joseph
    Jackson, Michael
    Metcalfe, Peter
    Rosenfeld, Anatoly B.
    Biasi, Giordano
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (02): : 185 - 193
  • [26] Study of the response of plastic scintillation detectors in small-field 6 MV photon beams by Monte Carlo simulations
    Wang, Lilie L. W.
    Beddar, Sam
    MEDICAL PHYSICS, 2011, 38 (03) : 1596 - 1599
  • [27] DESIGN OF DATA-INJECTION ADVERSARIAL ATTACKS AGAINST SPATIAL FIELD DETECTORS
    Lopez-Valcarce, Roberto
    Romero, Daniel
    2016 IEEE STATISTICAL SIGNAL PROCESSING WORKSHOP (SSP), 2016,
  • [28] Assessment of microscopic ion beam field variation using fluorescent nuclear track detectors
    Neuholz, Alexander
    Greilich, Steffen
    RADIATION MEASUREMENTS, 2017, 106 : 595 - 601
  • [29] Beyond the Alfonso Formalism for Small Field Dosimetry: A New Metric, New Detectors, Or Both?
    Underwood, T. S. A.
    Winter, H. C.
    Hill, M. A.
    Fenwick, J. D.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [30] Feasibility study of using Stereotactic Field Diode for field output factors measurement and evaluating three new detectors for small field relative dosimetry of 6 and 10 MV photon beams
    Gul, Attia
    Fukuda, Shigekazu
    Mizuno, Hideyuki
    Taku, Nakaji
    Kakakhel, M. Basim
    Mirza, Sikander M.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (11): : 23 - 36