Assessment of new small-field detectors against standard-field detectors for practical stereotactic beam data acquisition

被引:112
|
作者
McKerracher, C [1 ]
Thwaites, DI [1 ]
机构
[1] Western Gen Hosp, Edinburgh EH4 2XU, Midlothian, Scotland
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1999年 / 44卷 / 09期
关键词
D O I
10.1088/0031-9155/44/9/303
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Two new detectors (0.015 cm(3) ion chamber from PTW, 0.6 mm diameter diode from Scanditronix AB) designed specifically for use in small stereotactic fields were compared against similar, more routine, detectors (0.125 cm(3) ion chamber; parallel plate chamber, shielded and unshielded diodes and film). Percentage depth doses, tissue maximum ratios, off-axis ratios and relative output factors were compared for circular fields in the 40-12.5 mm diameter range, with a view to identifying the optimum detector for stereotactic beam data acquisition. Practical suggestions for beam data collection and analysis are made, with an emphasis on what is achievable practically in radiotherapy departments where the primary demand is to provide a routine service. No single detector was found to be ideal, and neither of the two new measurement devices had any significant advantages over more routine devices, in the situations measured. Although the new 0.015 cm(3) ion chamber was an improvement on a 0.125 cm(3) ion chamber in the measurement of profiles, it was still too large when compared with a diode. The new small diode had a low signal to noise ratio which made reliable data difficult to extract and its only advantage is possibly improved resolution in fields smaller than the range tested. The use of a larger unshielded diode is recommended for all measurements, with the additional cross-checking of data against at least one small ion chamber and film. A simple method of obtaining reliable output data from the detectors used is explained.
引用
收藏
页码:2143 / 2160
页数:18
相关论文
共 49 条
  • [1] Characterization of small-field stereotactic radiosurgery beams with modern detectors
    Tyler, Madelaine
    Liu, Paul Z. Y.
    Chan, Kin Wa
    Ralston, Anna
    McKenzie, David R.
    Downes, Simon
    Suchowerska, Natalka
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (21): : 7595 - 7608
  • [2] Measurement of Dosimetric Parameters of Stereotactic Cones with Small-Field Detectors
    Tamang, H. B. Moktan
    Setianegara, J.
    Soultan, D.
    Li, H.
    Jiang, H.
    MEDICAL PHYSICS, 2024, 51 (10) : 7973 - 7973
  • [3] Small-field radiotherapy photon beam output evaluation: Detectors reviewed
    Lam, S. E.
    Bradley, D. A.
    Khandaker, M. U.
    RADIATION PHYSICS AND CHEMISTRY, 2021, 178
  • [4] On Monolithic Silicon Array Detectors for Small-Field Photon Beam Dosimetry
    Biasi, Giordano
    Davis, Jeremy
    Petasecca, Marco
    Guatelli, Susanna
    Perevertaylo, Vladimir
    Kron, Tomas
    Rosenfeld, Anatoly B.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2018, 65 (09) : 2640 - 2649
  • [5] Influence of Jaw Setting in the Determination of Stereotactic Small-Field Output Factors with Different Detectors
    George, Seby
    Ponmalar, Y. Retna
    Godson, Henry Finlay
    Kumar, A. Sathish
    Ravindran, B. Paul
    JOURNAL OF MEDICAL PHYSICS, 2022, 47 (01) : 65 - 72
  • [6] A comparative study of three small-field detectors for patient specific stereotactic arc dosimetry
    Luke K. Webb
    Emma K. Inness
    Paul H. Charles
    Australasian Physical & Engineering Sciences in Medicine, 2018, 41 : 217 - 223
  • [7] A comparative study of three small-field detectors for patient specific stereotactic arc dosimetry
    Webb, Luke K.
    Inness, Emma K.
    Charles, Paul H.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2018, 41 (01) : 217 - 223
  • [8] Analysis of output factors with various detectors in small-field electron-beam radiotherapy
    Sang Hoon Lee
    Juree Kim
    Yoon Seok Nam
    SamJu Cho
    Sooil Kwon
    Suk Lee
    Jang Bo Shim
    Chul Yong Kim
    Chul Kee Min
    Kwang Hwan Cho
    HyunDo Huh
    Journal of the Korean Physical Society, 2012, 60 : 875 - 880
  • [9] Analysis of Output Factors with Various Detectors in Small-field Electron-beam Radiotherapy
    Lee, Sang Hoon
    Kim, Juree
    Nam, Yoon Seok
    Cho, Samju
    Kwon, Sooil
    Lee, Suk
    Shim, Jang Bo
    Kim, Chul Yong
    Min, Chul Kee
    Cho, Kwang Hwan
    Huh, HyunDo
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 60 (05) : 875 - 880
  • [10] Small-field dosimetry with multiple detectors and Monte Carlo calculations
    Parker, B
    Shin, A