Muscle powered blood pump: Design and initial test results

被引:3
|
作者
Trumble, DR
Magovern, JA
机构
[1] Allegheny Univ Hlth Sci, Pittsburgh, PA 15212 USA
[2] Allegheny Gen Hosp, Dept Surg, Pittsburgh, PA 15212 USA
关键词
D O I
10.1097/00002480-199905000-00014
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A pneumatic ventricular assist device (Sarns/3M) has been redesigned for low Volume hydraulic actuation to accommodate muscle powered drive systems. Design modifications include adding a bellows/piston mechanism (to compress the blood sac) and a compliance chamber for volume compensation. A simple prototype device was constructed to measure the efficacy of piston pump actuation and to validate pusher plate design. Device manufacture was affected by removing the drive line housing from the pneumatic pump and replacing it with a piston/bushing mechanism. A convex piston profile was chosen to maximize ejection fraction and minimize device size. Stroke volume was found to be a linear function of piston displacement (similar to 3 ml/mm) and reached a maximum value of 45 mi. Mean compression forces of 46-56 N acting during a 12 mm stroke (2.1 L/min at 60 cycles/min) were sufficient to generate mean afterload pressures of 70-110 mm Hg in a mock circulatory loop. Peak compression forces ranged from 72 to 86 N and work input was calculated to be 552-672 mJ/stroke. These data indicate that this method for delivering muscle power to the bloodstream is both mechanically viable and compatible with the functional capacity of conditioned latissimus dorsi muscle.
引用
收藏
页码:178 / 182
页数:5
相关论文
共 50 条
  • [41] Design, Build, and Test a Solar Powered Phone Charger
    Juang, Jeng-Nan
    Radharamanan, R.
    2019 IEEE SOUTHEASTCON, 2019,
  • [42] Development of design methods for a centrifugal blood pump with a fluid dynamic approach: Results in hemolysis tests
    Masuzawa, T
    Tsukiya, T
    Endo, S
    Tatsumi, E
    Taenaka, Y
    Takano, H
    Yamane, T
    Nishida, M
    Asztalos, B
    Miyazoe, Y
    Ito, K
    Sawairi, T
    Konishi, Y
    ARTIFICIAL ORGANS, 1999, 23 (08) : 757 - 761
  • [43] Multivariate Assessment of the Effect of Pump Design and Pump Gap Design Parameters on Blood Trauma
    Graefe, Roland
    Henseler, Andreas
    Steinseifer, Ulrich
    ARTIFICIAL ORGANS, 2016, 40 (06) : 568 - 576
  • [44] Design of Pump as Turbine Experimental Test Facility
    Zariatin, D. L.
    Rhakasywi, Damora
    Ade, Fahzul
    Setyo, Abdi
    2017 INTERNATIONAL CONFERENCE ON MECHANICAL, AERONAUTICAL AND AUTOMOTIVE ENGINEERING (ICMAA 2017), 2017, 108
  • [45] Walking Trajectory Design of Hydraulic Legged Robot with Limited Powered Pump
    Tani, Kosuke
    Nabae, Hiroyuki
    Hirota, Yoshiharu
    Endo, Gen
    Suzumori, Koichi
    2021 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA 2021), 2021, : 11463 - 11469
  • [46] DESIGN AND TEST OF A DIAPHRAGM PUMP FOR LIQUID METALS
    WESTERHEIDE, DE
    CLIFFORD, JC
    BURNET, G
    NUCLEAR SCIENCE AND ENGINEERING, 1963, 17 (04) : 523 - &
  • [48] Fibonacci Charge Pump Design, Test and Measurement
    Matousek, D.
    Subrt, O.
    Hospodka, J.
    2017 11TH INTERNATIONAL CONFERENCE ON MEASUREMENT, 2017, : 135 - 138
  • [49] Design of Photovoltaic Water Pumping System and Compare it with Diesel Powered Pump
    Abu-Aligah, M.
    JORDAN JOURNAL OF MECHANICAL AND INDUSTRIAL ENGINEERING, 2011, 5 (03): : 273 - 280
  • [50] REXEBIS -: Design and initial commissioning results
    Wenander, F
    Cederkäll, J
    Jonson, B
    Liljeby, L
    Nyman, G
    Rensfelt, KG
    Skeppstedt, O
    Wolf, B
    ELECTRON BEAM ION SOURCES AND TRAPS AND THEIR APPLICATIONS, 2001, 572 : 59 - 73