Muscle powered blood pump: Design and initial test results

被引:3
|
作者
Trumble, DR
Magovern, JA
机构
[1] Allegheny Univ Hlth Sci, Pittsburgh, PA 15212 USA
[2] Allegheny Gen Hosp, Dept Surg, Pittsburgh, PA 15212 USA
关键词
D O I
10.1097/00002480-199905000-00014
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A pneumatic ventricular assist device (Sarns/3M) has been redesigned for low Volume hydraulic actuation to accommodate muscle powered drive systems. Design modifications include adding a bellows/piston mechanism (to compress the blood sac) and a compliance chamber for volume compensation. A simple prototype device was constructed to measure the efficacy of piston pump actuation and to validate pusher plate design. Device manufacture was affected by removing the drive line housing from the pneumatic pump and replacing it with a piston/bushing mechanism. A convex piston profile was chosen to maximize ejection fraction and minimize device size. Stroke volume was found to be a linear function of piston displacement (similar to 3 ml/mm) and reached a maximum value of 45 mi. Mean compression forces of 46-56 N acting during a 12 mm stroke (2.1 L/min at 60 cycles/min) were sufficient to generate mean afterload pressures of 70-110 mm Hg in a mock circulatory loop. Peak compression forces ranged from 72 to 86 N and work input was calculated to be 552-672 mJ/stroke. These data indicate that this method for delivering muscle power to the bloodstream is both mechanically viable and compatible with the functional capacity of conditioned latissimus dorsi muscle.
引用
收藏
页码:178 / 182
页数:5
相关论文
共 50 条
  • [21] DESIGN AND INITIAL TESTING OF AN IMPLANTABLE INFUSION PUMP
    BLACKSHEAR, PJ
    BLACKSHE.PL
    BUCHWALD, H
    VARCO, RL
    DORMAN, FD
    SURGERY GYNECOLOGY AND OBSTETRICS WITH INTERNATIONAL ABSTRACTS OF SURGERY, 1972, 134 (01): : 51 - +
  • [22] Biohybrid valveless pump-bot powered by engineered skeletal muscle
    Li, Zhengwei
    Seo, Yongbeom
    Aydin, Onur
    Elhebeary, Mohamed
    Kamm, Roger D.
    Kong, Hyunjoon
    Saif, M. Taher A.
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2019, 116 (05) : 1543 - 1548
  • [23] DOES THE MUSCLE PUMP INCREASE MUSCLE BLOOD-FLOW
    BOONE, JB
    CRADER, SE
    LAUGHLIN, MH
    FASEB JOURNAL, 1995, 9 (04): : A907 - A907
  • [24] Initial test and results of an AwakeAnimalPET system
    Lee, S.
    Weisenberger, A. G.
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [25] Design of solar powered adsorption heat pump with ice storage
    Lambert, Michael A.
    APPLIED THERMAL ENGINEERING, 2007, 27 (8-9) : 1612 - 1628
  • [26] Design and development of a water piston solar powered steam pump
    Picken, DJ
    Seare, KDR
    Goto, F
    SOLAR ENERGY, 1997, 61 (03) : 219 - 224
  • [27] Performance test results for the laser-powered microthruster
    Phipps, Claude R.
    Luke, James R.
    Helgeson, Wesley
    Johnson, Richard
    BEAMED ENERGY PROPULSION, 2006, 830 : 224 - +
  • [28] Development and initial testing of a pediatric centrifugal blood pump
    Litwak, P
    Butler, KC
    Thomas, DC
    Taylor, LP
    Macha, M
    Yamazaki, K
    Konishi, H
    Kormos, RL
    Griffith, BP
    Borovetz, HS
    ANNALS OF THORACIC SURGERY, 1996, 61 (01): : 448 - 451
  • [29] TEST RESULTS OF THE CHRYSLER UPGRADED AUTOMOTIVE GAS TURBINE ENGINE - INITIAL DESIGN.
    Horvath, David
    Ribble Jr., Guy H.
    Warren, Edward L.
    Wood, James C.
    NASA Technical Memorandum, 1981,
  • [30] DESIGN-FEATURES AND INITIAL TEST-RESULTS OF AN 8 GHZ GYROTRON OSCILLATOR
    MUGGLI, P
    TRAN, MQ
    ALBERTI, S
    PERRENOUD, A
    MATHEWS, HG
    HELVETICA PHYSICA ACTA, 1987, 60 (5-6): : 834 - 834