Muscle powered blood pump: Design and initial test results

被引:3
|
作者
Trumble, DR
Magovern, JA
机构
[1] Allegheny Univ Hlth Sci, Pittsburgh, PA 15212 USA
[2] Allegheny Gen Hosp, Dept Surg, Pittsburgh, PA 15212 USA
关键词
D O I
10.1097/00002480-199905000-00014
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A pneumatic ventricular assist device (Sarns/3M) has been redesigned for low Volume hydraulic actuation to accommodate muscle powered drive systems. Design modifications include adding a bellows/piston mechanism (to compress the blood sac) and a compliance chamber for volume compensation. A simple prototype device was constructed to measure the efficacy of piston pump actuation and to validate pusher plate design. Device manufacture was affected by removing the drive line housing from the pneumatic pump and replacing it with a piston/bushing mechanism. A convex piston profile was chosen to maximize ejection fraction and minimize device size. Stroke volume was found to be a linear function of piston displacement (similar to 3 ml/mm) and reached a maximum value of 45 mi. Mean compression forces of 46-56 N acting during a 12 mm stroke (2.1 L/min at 60 cycles/min) were sufficient to generate mean afterload pressures of 70-110 mm Hg in a mock circulatory loop. Peak compression forces ranged from 72 to 86 N and work input was calculated to be 552-672 mJ/stroke. These data indicate that this method for delivering muscle power to the bloodstream is both mechanically viable and compatible with the functional capacity of conditioned latissimus dorsi muscle.
引用
收藏
页码:178 / 182
页数:5
相关论文
共 50 条
  • [31] Autonomous Microsystems for Downhole Applications: Design Challenges, Current State, and Initial Test Results
    Choi, Myungjoon
    Sui, Yu
    Lee, In Hee
    Meredith, Ryan
    Ma, Yushu
    Kim, Gyouho
    Blaauw, David
    Gianchandani, Yogesh B.
    Li, Tao
    SENSORS, 2017, 17 (10)
  • [32] Effects of muscle contraction on skeletal muscle blood flow: when is there a muscle pump?
    Laughlin, MH
    Schrage, WG
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1999, 31 (07): : 1027 - 1035
  • [33] Accuracy of an Initial Colonoscopy in Asymptomatic Patients with Positive Results in an Immunochemical Fecal Occult Blood Test
    Ishikawa, Keiko
    Tamura, Tomoyuki
    Takahashi, Hidemichi
    Hiratsuka, Hideo
    Ota, Shinichi
    GASTROINTESTINAL ENDOSCOPY, 2006, 63 (05) : AB211 - AB211
  • [34] Design of a Human Muscle-Powered Flying Machine
    Piotrowski, Igor
    Krolikowski, Marcin
    Urbanowicz, Kamil
    APPLIED SCIENCES-BASEL, 2024, 14 (19):
  • [35] Point: The muscle pump raises muscle blood flow during locomotion
    Sheriff, D
    JOURNAL OF APPLIED PHYSIOLOGY, 2005, 99 (01) : 371 - 372
  • [36] The muscle pump is not an important determinant of muscle blood flow during exercise
    Panchev, VS
    Suvandjieva, AV
    Pancheva, MV
    JOURNAL OF APPLIED PHYSIOLOGY, 2005, 99 (02) : 778 - 778
  • [37] Muscle pump does not enhance blood flow in exercising skeletal muscle
    Hamann, JJ
    Valic, Z
    Buckwalter, JB
    Naik, JS
    Clifford, PS
    FASEB JOURNAL, 2002, 16 (05): : A763 - A763
  • [38] Muscle pump does not enhance blood flow in exercising skeletal muscle
    Hamann, JJ
    Valic, Z
    Buckwalter, JB
    Clifford, PS
    JOURNAL OF APPLIED PHYSIOLOGY, 2003, 94 (01) : 6 - 10
  • [39] The muscle pump is/is not an important determinant of muscle blood flow during exercise
    Wray, DW
    JOURNAL OF APPLIED PHYSIOLOGY, 2005, 99 (02) : 772 - 772
  • [40] The muscle pump indeed raises muscle blood flow during locomotion
    Rothe, CF
    JOURNAL OF APPLIED PHYSIOLOGY, 2005, 99 (02) : 773 - 773