Muscle powered blood pump: Design and initial test results

被引:3
|
作者
Trumble, DR
Magovern, JA
机构
[1] Allegheny Univ Hlth Sci, Pittsburgh, PA 15212 USA
[2] Allegheny Gen Hosp, Dept Surg, Pittsburgh, PA 15212 USA
关键词
D O I
10.1097/00002480-199905000-00014
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A pneumatic ventricular assist device (Sarns/3M) has been redesigned for low Volume hydraulic actuation to accommodate muscle powered drive systems. Design modifications include adding a bellows/piston mechanism (to compress the blood sac) and a compliance chamber for volume compensation. A simple prototype device was constructed to measure the efficacy of piston pump actuation and to validate pusher plate design. Device manufacture was affected by removing the drive line housing from the pneumatic pump and replacing it with a piston/bushing mechanism. A convex piston profile was chosen to maximize ejection fraction and minimize device size. Stroke volume was found to be a linear function of piston displacement (similar to 3 ml/mm) and reached a maximum value of 45 mi. Mean compression forces of 46-56 N acting during a 12 mm stroke (2.1 L/min at 60 cycles/min) were sufficient to generate mean afterload pressures of 70-110 mm Hg in a mock circulatory loop. Peak compression forces ranged from 72 to 86 N and work input was calculated to be 552-672 mJ/stroke. These data indicate that this method for delivering muscle power to the bloodstream is both mechanically viable and compatible with the functional capacity of conditioned latissimus dorsi muscle.
引用
收藏
页码:178 / 182
页数:5
相关论文
共 50 条
  • [1] Solar-powered hydrogen refuelling station for unmanned aerial vehicles: Design and initial AC test results
    Troncoso, E.
    Lapena-Rey, N.
    Valero, O.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2014, 39 (04) : 1841 - 1855
  • [2] HTS cable test facility: Design and initial results
    Gouge, MJ
    Demko, JA
    Lue, JW
    Stovall, JP
    Hughey, RL
    Martin, R
    Sinha, U
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1999, 9 (02) : 134 - 137
  • [3] HTS cable test facility: design and initial results
    Oak Ridge Natl Lab, Oak Ridge, United States
    IEEE Trans Appl Supercond, 2 I (134-137):
  • [4] Design and initial test results of a space-bound flux pump to energize the Hēki mission's superconducting magnet
    Mallett, B. P. P.
    Clarke, J.
    Endo, T.
    Goddard-Winchester, M.
    Shellard, C.
    Olatunji, J.
    Badcock, R. A.
    Pollock, R.
    SUPERCONDUCTIVITY, 2024, 12
  • [5] THE VALVO-PUMP, AN AXIAL BLOOD PUMP IMPLANTED AT THE HEART-VALVE POSITION - CONCEPT AND INITIAL RESULTS
    YAMAZAKI, K
    OKAMOTO, E
    YAMAMOTO, K
    MITAMURA, Y
    TANAKA, T
    YOZU, R
    ARTIFICIAL ORGANS, 1992, 16 (03) : 297 - 299
  • [6] Design and test of wirelessly powered IPMC artificial muscle for aquatic ecosystem health applications
    Safari, Yousef
    Naghavi, Nadia
    Malayjerdi, Mohsen
    Kalani, Hadi
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2022, 33 (16) : 2074 - 2085
  • [7] FOREST-INTERFACE DISPERSION STUDY - TEST DESIGN AND INITIAL RESULTS
    BOWERS, JF
    RAFFERTY, JE
    BLEIWEISS, MP
    19TH CONFERENCE ON AGRICULTURAL AND FOREST METEOROLOGY AND NINTH CONFERENCE ON BIOMETEOROLOGY AND AEROBIOLOGY, 1989, : 207 - 210
  • [8] Design of the cold atom PHARAO space clock and initial test results
    Ph. Laurent
    M. Abgrall
    Ch. Jentsch
    P. Lemonde
    G. Santarelli
    A. Clairon
    I. Maksimovic
    S. Bize
    Ch. Salomon
    D. Blonde
    J.F. Vega
    O. Grosjean
    F. Picard
    M. Saccoccio
    M. Chaubet
    N. Ladiette
    L. Guillet
    I. Zenone
    Ch. Delaroche
    Ch. Sirmain
    Applied Physics B, 2006, 84 : 683 - 690
  • [9] Design of the cold atom PHARAO space clock and initial test results
    Laurent, Ph.
    Abgrall, M.
    Jentsch, Ch.
    Lemonde, P.
    Santarelli, G.
    Clairon, A.
    Maksimovic, I.
    Bize, S.
    Salomon, Ch.
    Blonde, D.
    Vega, J. F.
    Grosjean, O.
    Picard, F.
    Saccoccio, M.
    Chaubet, M.
    Ladiette, N.
    Guillet, L.
    Zenone, I.
    Delaroche, Ch.
    Sirmain, Ch.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2006, 84 (04): : 683 - 690
  • [10] BLOOD PUMP POWERED AND CONTROLLED BY A FLUID AMPLIFICATION SYSTEM
    BARILA, TG
    WOODWARD, KE
    NUNN, DB
    TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1962, 8 : 30 - &